Available on request

FR-D820-0.4K-025-EPB-60 Mitsubishi FREQROL inverter FR-D800

MPN: FR-D820-0.4K-025-EPB-60 · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – FREQROL-D800
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-D820-0.4K-025-EPB-60 be shipped?

FR-D820-0.4K-025-EPB-60 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-D820-0.4K-025-EPB-60 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-D820-0.4K-025-EPB-60 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-D820-0.4K-025-EPB-60, subject to availability and destination.

The Mitsubishi Electric FR-D820-0.4K-025-EPB-60 is a FR-D800 in the FREQROL inverter. cULus CE(LVD). Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryFR-D800
OutlinecULus CE(LVD)

Specifications

SeriesFR-D800
TypeThree-phase 200 V class Ethernet model
Model nameFR-D820-0.4K-025-EPB-60
Inverter capacity (kW)0.4
Applicable motor capacity (kW) *1: SLD0.75
Applicable motor capacity (kW) *1: ND0.4
Output: Rated capacity (kVA) *2: SLD1.6
Output: Rated capacity (kVA) *2: ND1.0
Output: Rated current (A) *7: SLD4.2 (3.5)
Output: Rated current (A) *7: ND2.5
Output: Overload current rating *3: SLD110 % 60 s, 120 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C
Output: Overload current rating *3: ND150 % 60 s, 200 % 0.5 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output: Voltage *4Three-phase 200 to 240 V
Output: Regenerative braking: Brake transistorBuilt-in
Output: Regenerative braking: Maximum brake torque (ND reference) *5100 %
Power supply *9: Rated input AC voltage and frequencyThree-phase 200 to 240 V, 50/60 Hz
Power supply *9: Permissible AC voltage fluctuation170 to 264 V, 50/60 Hz
Power supply *9: Permissible frequency fluctuation±5 %
Power supply *9: Rated input current (A) without DC reactor *8: SLD5.6
Power supply *9: Rated input current (A) without DC reactor *8: ND3.7
Power supply *9: Rated input current (A) with DC reactor *8: SLD4.2
Power supply *9: Rated input current (A) with DC reactor *8: ND2.5
Power supply *9: Power supply capacity (kVA) without DC reactor *6: SLD2.1
Power supply *9: Power supply capacity (kVA) without DC reactor *6: ND1.4
Power supply *9: Power supply capacity (kVA) with DC reactor *6: SLD1.6
Power supply *9: Power supply capacity (kVA) with DC reactor *6: ND1.0
Protective structure: IEC 60529IP20
Cooling systemNatural
Approx. mass (kg)0.6
Control: Control method: CommonSoft-PWM control/High carrier frequency PWM control
Control: Control method: Induction motorSelectable among V/F control, Advanced magnetic flux vector control
Control: Control method: PM motorPM sensorless vector control
Control: Output frequency range: Induction motor0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control.)
Control: Output frequency range: PM motor0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency)
Control: Frequency setting and resolution: Analog input0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4)
Control: Frequency setting and resolution: Digital input0.01 Hz
Control: Frequency accuracy: Analog inputWithin ±0.2 % of the maximum output frequency (25 °C ±10 °C)
Control: Frequency accuracy: Digital input0.01 % or less of the set output frequency
Control: Voltage/frequency characteristicsBase frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern can be selected (with induction motor only).
Control: Starting torque: Induction motorThe following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 150% at 0.5 Hz (Advanced magnetic flux vector control)
Control: Starting torque: PM motor50 %
Control: Torque boostManual torque boost (induction motor only)
Control: Acceleration/deceleration time setting0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration modes are available.
Control: DC injection brake: Induction motorOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable
Control: DC injection brake: PM motorOperation time (0 to 10 s) variable. Operating voltage (operating current) fixed.
Control: Stall prevention operation levelOperation current : 0 to 200 % variable, with selectable availability of the function
Control: Torque limit levelTorque limit value can be set (0 to 400 % variable). (PM sensorless vector control)
Operation: Frequency setting signal: Number of analog input2
Operation: Frequency setting signal: Specification of analog inputTerminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA)
Operation: Frequency setting signal: Digital inputInput using the operation panel or parameter unit
Operation: Frequency setting signal: Pulse train input100 k pulses/s
Operation: Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation: Input signal: Number of input signal (Contact input)5
Operation: Input signal: Input terminal function selectable signalForward rotation command, Reverse rotation command The signal to be input can be changed using Pr.178 to Pr.182 (Input terminal function selection).
Operation: Operational functionMaximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Remote setting, Retry function, Car
Operation: Output signal: Number of output signal (Open collector output)1
Operation: Output signal: Number of output signal (Relay output)1
Operation: Output signal: Output terminal function selectable signalInverter running, Fault The signal to be output can be changed using Pr.190 and Pr.192 (Output terminal function selection).
Operation: Output signal: Analog output (AM type inverter)Terminals AM : 0 to +10 V/12 bit
Protective/warning function: Protective functionOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio
Protective/warning function: Warning functionFan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Regenerative brake pre-alarm *10 , Electronic thermal relay function pre-alarm, PU stop, Maintenance timer, Parameter write error, Operation panel lock *10 , Password locked *10 , Safety stop, Load fault warning *10 , Emergency drive in operation *10 , Continuous operation during communication fault *10 , Ethernet communica
Environment: Surrounding air temperature-20 °C to +60 °C (non-freezing) SLD rating : The rated current must be reduced at a temperature above 40 °C. ND rating : The rated current must be reduced at a temperature above 50 °C.
Environment: Surrounding air humidity95 % RH or less (non-condensing)
Environment: Storage temperature *11-40 °C to +70 °C
Environment: AmbienceIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Environment: Altitude/vibrationMaximum 3000 m *12 , 5.9 m/s 2 or less at 10 to 55 Hz in X, Y, and Z directions
NetworkEthernet : CC-Link IE TSN, CC-Link IE Field Network Basic, MODBUS/TCP, PROFINET

Downloads & documentation

Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.

Data sheets & manuals

FR-D800-E INVERTER SAFETY GUIDELINE (IB-0601022E-B)PDF · 1.31MB
FR-D800-E INVERTER SAFETY GUIDELINE (IB-0601023C-B)PDF · 1.29MB
FR-D800(-E) INSTRUCTION MANUAL (Connection) (IB-0601031ENG-B)PDF · 6.82MB
FR-D800(-E) INSTRUCTION MANUAL (Connection) (IB-0601032CHN-B)PDF · 6.96MB
FR-D800(-E) INSTRUCTION MANUAL (Function) (IB-0601036ENG-C)PDF · 6.48MB
FR-D800(-E) INSTRUCTION MANUAL (Function) (IB-0601037CHN-C)PDF · 5.03MB
FR-D800(-E) INSTRUCTION MANUAL (Communication) (IB-0601041ENG-A)PDF · 4.56MB
FR-D800(-E) INSTRUCTION MANUAL (Communication) (IB-0601042CHN-A)PDF · 3.84MB
FR-D800(-E) INSTRUCTION MANUAL (Maintenance) (IB-0601046ENG-B)PDF · 1.77MB
FR-D800(-E) INSTRUCTION MANUAL (Maintenance) (IB-0601047CHN-B)PDF · 2.12MB
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-D820-0.2K-014-EPA-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.2K-014-EPA-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.2K-014-EPA-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-0.2K-014-EPB-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.2K-014-EPB-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.2K-014-EPB-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-0.4K-025-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.4K-025-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.4K-025-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-0.4K-025-EPA-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.4K-025-EPA-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.4K-025-EPA-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-0.75K-042-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.75K-042-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.75K-042-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-0.75K-042-EPA-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.75K-042-EPA-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.75K-042-EPA-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-0.75K-042-EPB-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-0.75K-042-EPB-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-0.75K-042-EPB-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D820-1.5K-070-60 Mitsubishi FREQROL inverter FR-D800Available on requestFR-D820-1.5K-070-60 Mitsubishi FREQROL inverter FR-D800
MPN: FR-D820-1.5K-070-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote