Available on request

FR-D740-036SC-EC Mitsubishi FREQROL inverter FR-D700

MPN: FR-D740-036SC-EC · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – FREQROL-D700
LifecycleActive mature
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-D740-036SC-EC be shipped?

FR-D740-036SC-EC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-D740-036SC-EC in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-D740-036SC-EC and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-D740-036SC-EC, subject to availability and destination.

The Mitsubishi Electric FR-D740-036SC-EC is a FR-D700 in the FREQROL inverter. cULus CE(LVD). Mitsubishi Electric has announced its discontinuation (2027/01 To be discontinued) — plan spares now; PartnerPLC also sources it on the surplus market after the end of order. Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryFR-D700
Sales status2027/01 To be discontinued (Mitsubishi Electric)
OutlinecULus CE(LVD)

Specifications

seriesFR-D700
typeThree-phase 400 V class Source-logic safety terminal
Model nameFR-D740-036SC-EC
Inverter capacity (kW)1.5
Applicable motor capacity (kW) *11.5
output: Rated capacity (kVA) *22.7
output: Rated current (A) *33.6 (4.3)
output: Overload current rating *4150 % 60 s, 200 % 0.5 s (inverse-time characteristics)
output: Rated voltage *5Three-phase 380 to 480 V
output: Regenerative braking: Maximum brake torque *650 %
Power supply: Rated input AC voltage and frequencyThree-phase 380 to 480 V 50 Hz/60 Hz
Power supply: Permissible AC voltage fluctuation325 to 528 V 50 Hz/60 Hz
Power supply: Permissible frequency fluctuation±5 %
Power supply: Power supply capacity (kVA) *74.5
Protection rating of structure (JEM 1030)IP20
Cooling systemForced air
Approx. mass (kg)1.4
Control: Control methodSoft-PWM control/high carrier frequency PWM control (V/F control, General-purpose magnetic flux vector control, and Optimum excitation control are available)
Control: Output frequency range0.2 to 400 Hz
Control: Frequency setting and resolution: Analog input0.06 Hz/60 Hz (terminals 2, 4 : 0 to 10 V/10 bits) 0.12 Hz/60 Hz (terminals 2, 4 : 0 to 5 V/9 bits) 0.06 Hz/60 Hz (terminal 4 : 0 to 20 mA/10 bits)
Control: Frequency setting and resolution: Digital input0.01 Hz
Control: Frequency accuracy: Analog inputWithin ±1 % of the max. output frequency (25 °C ±10 °C)
Control: Frequency accuracy: Digital inputWithin 0.01 % of the set output frequency
Control: Voltage/frequency characteristicsBase frequency can be set from 0 to 400 Hz. Constant-torque/variable torque pattern can be selected
Control: Starting torque150 % or more (at 1 Hz)...when General-purpose magnetic flux vector control and slip compensation is set
Control: Torque boostManual torque boost
Control: Acceleration/deceleration time setting0.1 to 3600 s (acceleration and deceleration can be set individually), Linear and S-pattern acceleration/deceleration modes are available.
Control: DC injection brake (induction motor)Operation frequency (0 to 120 Hz), operation time (0 to 10 s), and operation voltage (0 to 30 %) can be changed
Control: Stall prevention operation levelOperation current level (0 to 200 %), and whether to use the function or not can be selected
Operation: Frequency setting signal: Nuber of Analog input2
Operation: Frequency setting signal: Specification of Analog inputTerminal 2 : 0 to 10 V and 0 to 5 V are available Terminal 4 : 0 to 10 V, 0 to 5 V, and 4 to 20 mA are available
Operation: Frequency setting signal: Digital inputThe signal is entered from the operation panel or parameter unit. Frequency setting increment can be set.
Operation: Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation: Input signal: Nuber of Input signal (Contact input)5
Operation: Input signal: Input terminal function selectable signalThe following signals can be assigned to Pr. 178 to Pr. 182 (input terminal function selection) : Multi-speed selection, Remote setting, Second function selection, Terminal 4 input selection, JOG operation selection, PID control valid terminal, External thermal input, PU-External operation switchover, V/F switchover, Output stop, Start self-holding selection, Traverse function selection, Forward r
Operation: Operational functionMaximum and minimum frequency settings, Frequency jump, External thermal relay input selection, Automatic restart after instantaneous power failure, Forward/reverse rotation prevention, Remote setting, Second function, Multi-speed operation, Regeneration avoidance, Slip compensation, Operation mode selection, Offline auto tuning function, PID control, RS-485 communication, Optimum excitation contr
Operation: Output signal: Number of output signal (Open collector output)2
Operation: Output signal: Number of output signal (Relay output)1
Operation: Output signal: Output terminal function selectable signalThe following signals can be assigned to Pr. 190, Pr. 192 and Pr. 197 (output terminal function selection) : Inverter operation, Up-to-frequency, Overload alarm, Output frequency detection, Regenerative brake pre-alarm, Electronic thermal relay function pre-alarm, Inverter operation ready, Output current detection, Zero current detection, PID lower limit, PID upper limit, PID forward/reverse rotat
Indication: Operation panel Parameter unit (FR-PU07): Status monitoringThe following operating status can be displayed : Output frequency, Output current (steady), Output voltage, Frequency setting, Cumulative energization time, Actual operation time, Converter output voltage, Regenerative brake duty, Electronic thermal relay function load factor, Output current peak value, Converter output voltage peak value, Motor load factor, PID set point, PID measured value, PID
Indication: Operation panel Parameter unit (FR-PU07): Fault monitoringFault record is displayed when a fault occurs. Past 8 fault records (output voltage/current/frequency/cumulative energization time right before the fault occurs) are stored.
Indication: Operation panel Parameter unit (FR-PU07): Interactive guidanceFunction (help) for operation guide *9
Protective function: FaultOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio
Protective function: Alarm,Warning, Error messageFan alarm *8 , Stall prevention (overcurrent), Stall prevention (overvoltage), PU stop, Parameter write error, Regenerative brake pre-alarm *10 , Electronic thermal relay function pre-alarm, Maintenance timer *10 , Undervoltage, Operation panel lock, Password locked, Inverter reset, Safety stop
Environment: Surrounding air temperature-10 °C to +50 °C maximum (non-freezing) *11
Environment: Surrounding air humidity90 % RH or less (non-condensing)
Environment: Storage temperature *12-20 °C to +65 °C
Environment: AmbienceIndoors (without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Environment: Altitude/vibrationMaximum 1000 m for standard operation (For the installation at an altitude above 1000 m up to 2500 m, consider a 3 % reduction in the rated current per 500 m increase in altitude.) 5.9 m/s 2 or less at 10 to 55 Hz (directions of X, Y, Z axes)
NetworkRS-485 : Mitsubishi inverter protocol, MODBUS RTU
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-D740-012SC-EC Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-012SC-EC Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-012SC-EC · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-022-NA Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-022-NA Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-022-NA · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-022SC-EC Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-022SC-EC Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-022SC-EC · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-036-NA Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-036-NA Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-036-NA · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-050-NA Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-050-NA Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-050-NA · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-050SC-EC Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-050SC-EC Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-050SC-EC · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-080-NA Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-080-NA Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-080-NA · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-D740-080SC-EC Mitsubishi FREQROL inverter FR-D700Available on requestFR-D740-080SC-EC Mitsubishi FREQROL inverter FR-D700
MPN: FR-D740-080SC-EC · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote