Available on request

FR-CS84-012-60 Mitsubishi FREQROL inverter FR-CS80

MPN: FR-CS84-012-60 · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – FREQROL-CS80
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-CS84-012-60 be shipped?

FR-CS84-012-60 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-CS84-012-60 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-CS84-012-60 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-CS84-012-60, subject to availability and destination.

The Mitsubishi Electric FR-CS84-012-60 is a FR-CS80 in the FREQROL inverter. cULus CE(LVD). Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryFR-CS80
OutlinecULus CE(LVD)

Specifications

seriesFR-CS80
typeThree-phase 400 V class
Model nameFR-CS84-012-60
Inverter capacity (kW)0.4
Applicable motor capacity (kW) *10.4
output: Rated capacity (kVA) *20.9
output: Rated current (A) *31.2 (1.0)
output: Overload current rating *4150 % 60 s, 200 % 0.5 s (inverse-time characteristics)
output: Rated voltage *5Three-phase 380 to 480 V
Power supply: Rated input AC voltage and frequencyThree-phase 380 to 480 V, 50/60 Hz
Power supply: Permissible AC voltage fluctuation325 to 528 V, 50/60 Hz
Power supply: Permissible frequency fluctuation±5 %
Power supply: Power supply capacity (kVA) *61.5
Protection rating of structure(IEC 60529)IP20
Cooling systemNatural
Approx. mass (kg)0.6
Control: Control methodSoft-PWM control, high carrier frequency PWM control (selectable among V/F control, General-purpose magnetic flux vector control, Optimum excitation control).
Control: Output frequency range0.2 to 400 Hz.
Control: Frequency setting and resolution: Analog input0.06/60 Hz at 0 to 10 V / 10 bits (terminals 2 and 4). 0.12/60 Hz at 0 to 5 V / 9 bits (terminals 2 and 4). 0.06/60 Hz at 0 to 20 mA / 10 bits (terminal 4).
Control: Frequency setting and resolution: Digital input0.01 Hz.
Control: Frequency accuracy: Analog inputWithin ±1 % of the maximum output frequency at 25 °C (±10 °C).
Control: Frequency accuracy: Digital input0.01 % or less of the set output frequency
Control: Voltage/frequency characteristicsBase frequency can be set from 0 to 400 Hz. Constant-torque or adjustable 3 points V/F can be selected.
Control: Starting torque150 % or more (at 1 Hz)...when General-purpose magnetic flux vector control and slip compensation is set
Control: Torque boostManual torque boost.
Control: Acceleration/deceleration time setting0.1 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration modes are available.
Control: DC injection brake (induction motor)Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable.
Control: Stall prevention operation levelOperation current : 0 to 200 % variable, with selectable availability of the function.
Operation: Frequency setting signal: Nuber of Analog input2
Operation: Frequency setting signal: Specification of Analog inputTerminal 2 : 0 to 10 V / 0 to 5 V. Terminal 4 : 0 to 10 V / 0 to 5 V / 4 to 20 mA.
Operation: Frequency setting signal: Digital inputInput from the PU, with selectable frequency setting increments.
Operation: Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation: Input signal: Nuber of Input signal (Contact input)5
Operation: Input signal: Input terminal function selectable signalUsing Pr. 178 to Pr. 182 (input terminal function selection), the signal can be selected from the following : Multi-speed selection, Remote setting, Second acceleration/deceleration function selection, Terminal 4 input selection, JOG operation selection, PID control valid terminal, External thermal relay input, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation c
Operation: Operational functionMaximum and minimum frequency settings, Frequency jump, External thermal relay input selection, Automatic restart after instantaneous power failure, Forward/reverse rotation prevention, Remote setting, Second function, Multi-speed operation, Regeneration avoidance, Slip compensation, Operation mode selection, Offline auto tuning function, PID control, RS-485 communication, Optimum excitation contr
Operation: Output signal: Number of output signal (Open collector output)1
Operation: Output signal: Number of output signal (Relay output)0
Operation: Output signal: Output terminal function selectable signalUsing Pr. 195 output terminal function selection, the signal can be selected from the following : Inverter running, Up to frequency, Overload warning, Output frequency detection, Electronic thermal O/L relay pre-alarm, Inverter operation ready, Output current detection, PID lower limit, PID upper limit, PID forward/reverse rotation output, Heatsink overheat pre-alarm, During deceleration at occurr
Indication: Operation panel Parameter unit (FR-PU07): Status monitoringSelectable from the following : output frequency, output current(steady state), output voltage, frequency setting, cumulative energization time, actual operation time, converter output voltage, electronic thermal relay function load factor, motor load factor, PID set point, PID measured value, PID deviation, inverter I/O terminal monitor, output power, cumulative power, motor thermal load factor,
Indication: Operation panel Parameter unit (FR-PU07): Fault monitoringFault record is displayed when a protective function is activated. Past 8 fault records are stored. (output voltage, output current, frequency, and cumulative energization time right before the protective function is activated.)
Indication: Operation panel Parameter unit (FR-PU07): Interactive guidanceHelp function for operation guide *7
Protective function: FaultRegenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay function), Heat sink overheat, Input phase loss, Output side earth (ground) fault overcurrent, Output short circuit, Output phase l
Protective function: Alarm,Warning, Error messageStall prevention (overcurrent), Stall prevention (overvoltage), PU stop, Parameter write error, Electronic thermal relay function pre-alarm, Undervoltage, Inrush current limit resistor heating, Operation panel lock, Password locked, Inverter reset, Emergency drive in operation *8
Environment: Surrounding air temperature-10 to +40 °C (non-freezing) *9 , 40 to +50 °C (non-freezing) at the rated current reduced by 15 %.
Environment: Surrounding air humidity95 % RH or less (non-condensing) for models with circuit board coating.
Environment: Storage temperature *11-20 to +65 °C
Environment: AmbienceIndoors (free from corrosive gas, flammable gas, oil mist, dust or dirt).
Environment: Altitude/vibrationMaximum 2500 m *12 , 5.9 m/s 2 or less at 10 to 55 Hz (directions of X, Y, Z axes)
NetworkRS-485 : Mitsubishi inverter protocol, MODBUS RTU

Downloads & documentation

Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.

Data sheets & manuals

FREQROL-CS80 Instructions and Cautions for Use of Inverters (IB-0600720E-C)PDF · 3.07MB
FREQROL-CS80 INSTRUCTION MANUAL (DETAILED) (IB-0600721ENG-D)PDF · 6.16MB
FREQROL-CS80 Instructions and Cautions for Use of Inverters (IB-0600720C-C)PDF · 3.07MB
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-CS82S-025-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS82S-025-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS82S-025-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS82S-042-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS82S-042-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS82S-042-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS82S-070-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS82S-070-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS82S-070-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS82S-100-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS82S-100-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS82S-100-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS84-022-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS84-022-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS84-022-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS84-036-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS84-036-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS84-036-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS84-050-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS84-050-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS84-050-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-CS84-080-60 Mitsubishi FREQROL inverter FR-CS80Available on requestFR-CS84-080-60 Mitsubishi FREQROL inverter FR-CS80
MPN: FR-CS84-080-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote