FR-CC2-N450K-60P Mitsubishi FREQROL inverter Converter unit
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi FREQROL inverter – Option |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FR-CC2-N450K-60P be shipped?
FR-CC2-N450K-60P is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FR-CC2-N450K-60P in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FR-CC2-N450K-60P and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-CC2-N450K-60P, subject to availability and destination.
The Mitsubishi Electric FR-CC2-N450K-60P is a converter unit in the FREQROL inverter. Converter unit FR-CC2 Series. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | FREQROL inverter |
| Category | Converter unit |
| Outline | Converter unit FR-CC2 Series |
Specifications
| Series | Option |
| Category | Converter unit |
| Type | Three-phase 690V class Parallel operation |
| Model name | FR-CC2-N450K-60P |
690 VAC power input (Single unit)
| Applicable motor capacity (kW) | 450.0 |
| Output: Overload current rating *1 | 150 % 60 s, 200 % 3 s at surrounding air temperature of 40 °C |
| Output: Rated DC voltage *2 | 849 to 976 VDC *4 |
| Power supply: Power supply capacity (kVA) *3 | 612.0 |
| Power supply: Rated input current (A) *5 | 512.0 |
| Power supply: Rated input AC voltage/frequency | Three-phase 600 V to 690 V 50/60 Hz |
| Power supply: Permissible AC voltage fluctuation | Three-phase 540 V to 759 V 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Protective structure: IEC 60529 | IP00 |
| Cooling system | Forced air |
| DC reactor | Built-in |
| Approx. mass (kg) *6 | 237.0 |
690 VAC power input (Two units in parallel)
| Applicable motor capacity (kW) | 710.0 |
| Output: Overload current rating *1 | 150 % 60 s, 200 % 3 s at surrounding air temperature of 40 °C |
| Output: Rated DC voltage *2 | 849 to 976 VDC *4 |
| Power supply: Power supply capacity (kVA) *3 | 979.0 |
| Power supply: Rated input current (A) *5 | 819.0 |
| Power supply: Rated input AC voltage/frequency | Three-phase 600 V to 690 V 50/60 Hz |
| Power supply: Permissible AC voltage fluctuation | Three-phase 540 V to 759 V 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Protective structure: IEC 60529 | IP00 |
| Cooling system | Forced air |
| DC reactor | Built-in |
| Approx. mass (kg) *6 | 474.0 |
690 VAC power input (Three units in parallel)
| Applicable motor capacity (kW) | 1000.0 |
| Output: Overload current rating *1 | 150 % 60 s, 200 % 3 s at surrounding air temperature of 40 °C |
| Output: Rated DC voltage *2 | 849 to 976 VDC *4 |
| Power supply: Power supply capacity (kVA) *3 | 1468.0 |
| Power supply: Rated input current (A) *5 | 1228.0 |
| Power supply: Rated input AC voltage/frequency | Three-phase 600 V to 690 V 50/60 Hz |
| Power supply: Permissible AC voltage fluctuation | Three-phase 540 V to 759 V 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Protective structure: IEC 60529 | IP00 |
| Cooling system | Forced air |
| DC reactor | Built-in |
| Approx. mass (kg) *6 | 711.0 |
575 VAC power input (Single unit)
| Applicable motor capacity (kW) | 355.0 |
| Output: Overload current rating *1 | 150 % 60 s, 200 % 3 s at surrounding air temperature of 40 °C |
| Output: Rated DC voltage *2 | 742 to 849 VDC *4 |
| Power supply: Power supply capacity (kVA) *3 | 510.0 |
| Power supply: Rated input current (A) *5 | 512.0 |
| Power supply: Rated input AC voltage/frequency | Three-phase 525 V to 600 V 50/60 Hz |
| Power supply: Permissible AC voltage fluctuation | Three-phase 472 V to 660 V 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Protective structure: IEC 60529 | IP00 |
| Cooling system | Forced air |
| DC reactor | Built-in |
| Approx. mass (kg) *6 | 237.0 |
575 VAC power input (Two units in parallel)
| Applicable motor capacity (kW) | 560.0 |
| Output: Overload current rating *1 | 150 % 60 s, 200 % 3 s at surrounding air temperature of 40 °C |
| Output: Rated DC voltage *2 | 742 to 849 VDC *4 |
| Power supply: Power supply capacity (kVA) *3 | 816.0 |
| Power supply: Rated input current (A) *5 | 819.0 |
| Power supply: Rated input AC voltage/frequency | Three-phase 525 V to 600 V 50/60 Hz |
| Power supply: Permissible AC voltage fluctuation | Three-phase 472 V to 660 V 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Protective structure: IEC 60529 | IP00 |
| Cooling system | Forced air |
| DC reactor | Built-in |
| Approx. mass (kg) *6 | 474.0 |
575 VAC power input (Three units in parallel)
| Applicable motor capacity (kW) | 800.0 |
| Output: Overload current rating *1 | 150 % 60 s, 200 % 3 s at surrounding air temperature of 40 °C |
| Output: Rated DC voltage *2 | 742 to 849 VDC *4 |
| Power supply: Power supply capacity (kVA) *3 | 1223.0 |
| Power supply: Rated input current (A) *5 | 1228.0 |
| Power supply: Rated input AC voltage/frequency | Three-phase 525 V to 600 V 50/60 Hz |
| Power supply: Permissible AC voltage fluctuation | Three-phase 472 V to 660 V 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Protective structure: IEC 60529 | IP00 |
| Cooling system | Forced air |
| DC reactor | Built-in |
| Approx. mass (kg) *6 | 711.0 |
Common specifications
| Input signal: Number of input signal (Contact input) | 3 |
| Input signal: Input terminal function selectable signal | External thermal relay input, converter reset. The signal to be input can be changed using Pr. 178, Pr. 187, or Pr. 189 (Input terminal function selection). |
| Operational function | Thermal protection, DC injection brake, automatic restart after instantaneous power failure, RS-485 communication, life diagnosis, maintenance timer, 24 V power supply input for control circuit |
| Output signal: Number of output signal (Open collector output) | 5 |
| Output signal: Number of output signal (Relay output) | 1 |
| Output signal: Output terminal function selectable signal | Inverter operation enable (NO contact) (positive logic, negative logic), Instantaneous power failure/undervoltage, Inverter reset, Fan fault output, Fault The signal to be output can be changed using Pr. 190 to Pr. 195 (Output terminal function selection). |
| Operation panel *9: Status monitoring | Converter output voltage, input current, electric thermal relay function load factor The item for monitoring can be changed using Pr. 774 to Pr. 776 Operation panel monitor selection 1 to 3. |
| Operation panel *9: Fault monitoring | When a protective function is activated, a fault indication is displayed and the converter output voltage, input current, electronic thermal relay function load factor, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed. |
| Protective/warning function: Protective function | Overvoltage trip, Converter overload trip (electronic thermal relay function), Heat sink overheat, Instantaneous power failure, Undervoltage, Input phase loss, External thermal relay operation, PU disconnection *8 , Parameter storage device fault (control circuit board), Parameter storage device fault (main circuit board), CPU fault, 24 VDC power fault, Inrush current limit circuit fault, Communic |
| Protective/warning function: Warning function | Fan alarm, Electronic thermal relay function pre-alarm, Maintenance signal output *8 , Operation panel lock *8 , Password locked *8 , Parameter write error, Copy operation error, 24 V external power supply operation, Emergency drive in operation *8 |
| Noise *10 | 74 dB (single-unit operation) |
| Environment: Surrounding air temperature | -10 °C to +40 °C (non-freezing) |
| Environment: Surrounding air humidity | 95 % RH or less (non-condensing) |
| Environment: Storage temperature *7 | -20 °C to +65 °C |
| Environment: Ambience | Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) |
| Environment: Altitude/vibration | 4000 m or less (For installation at an altitude above 1000 m, consider a 3 % reduction in the rated current per 500 m increase in altitude.) Frequency range 10 to 57 Hz : maximum amplitude 0.075 mm. Frequency range 57 to 150 Hz : maximum acceleration speed 1 G. |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
| FR-CC2-N-P INSTRUCTION MANUAL (IB-0600916ENG-B) | PDF · 4.93MB |
| FR-CC2-N-P INSTRUCTION MANUAL (IB-0600917CHN-B) | PDF · 5.01MB |
More Mitsubishi Electric (Factory Automation) parts
Available on requestFR-CC2-H560K-60 Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-H560K-60P Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-H630K-60 Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-N450K-60 Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-N500K-60 Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-N500K-60P Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-N560K-60 Mitsubishi FREQROL inverter Converter unit
Available on requestFR-CC2-N560K-60P Mitsubishi FREQROL inverter Converter unit