Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – FREQROL-A800
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-A862-05450-E1-60 be shipped?

FR-A862-05450-E1-60 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-A862-05450-E1-60 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-A862-05450-E1-60 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-A862-05450-E1-60, subject to availability and destination.

The Mitsubishi Electric FR-A862-05450-E1-60 is a FR-A800 in the FREQROL inverter. cULus. Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryFR-A800
OutlinecULus

Specifications

SeriesFR-A800
TypeThree-phase 600 V class Separated converter Ethernet model
Model nameFR-A862-05450-E1-60
Inverter capacity (kW)280.0
Applicable motor capacity (kW) *1: SLD400.0
Applicable motor capacity (kW) *1: LD355.0
Applicable motor capacity (kW) *1: ND280.0
Applicable motor capacity (kW) *1: HD220.0
Output: Rated capacity (kVA) *2: SLD543.0
Output: Rated capacity (kVA) *2: LD494.0
Output: Rated capacity (kVA) *2: ND401.0
Output: Rated capacity (kVA) *2: HD303.0
Output: Rated current (A) *3: SLD545.0 (463.0)
Output: Rated current (A) *3: LD496.0 (421.0)
Output: Rated current (A) *3: ND402.0 (341.0)
Output: Rated current (A) *3: HD304.0 (258.0)
Output: Overload current rating *4: SLD110 % 60 s, 120 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C
Output: Overload current rating *4: LD120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output: Overload current rating *4: ND150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 50 °C
Output: Overload current rating *4: HD200 % 60 s, 250 % 3 s, 280 % 0.5 s (inverse-time characteristics) at surrounding air temperature of 40 °C
Output: Voltage *5Three-phase 525 to 600 V
Output: Regenerative braking *6: Maximum brake torque (ND reference)10 % torque/continuous
Input power: Power supply voltage618 to 933 VDC
Input power: Control power supply auxiliary inputSingle-phase 525 to 600 V, 50/60 Hz
Input power: Permissible control power supply auxiliary input fluctuationFrequency ±5 %, voltage ±10 %
Protective structure: IEC 60529IP00
Cooling systemForced air cooling
Approx. mass (kg)163.0
Control: Control method: CommonSoft-PWM control/High carrier frequency PWM control
Control: Control method: Induction motorSelectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *7
Control: Control method: PM motorSelectable among PM sensorless vector control, and Vector control *7
Control: Output frequency range: Induction motor0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *7 .)
Control: Output frequency range: PM motor0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency)
Control: Frequency setting and resolution: Analog input0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4), at 0 to ±10 V/12 bits (terminal 1) 0.06 Hz/60 Hz at 0 to ±5 V/11 bits (terminal 1)
Control: Frequency setting and resolution: Digital input0.01 Hz
Control: Frequency accuracy: Analog inputWithin ±0.2 % of the maximum output frequency (25 °C ±10 °C)
Control: Frequency accuracy: Digital input0.01 % or less of the set output frequency
Control: Voltage/frequency characteristicsBase frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern or adjustable 5 points V/F can be selected.
Control: Starting torque: Induction motorThe following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 150 % at 0.3 Hz (Real sensorless vector control) 150 % at 0 Hz (Vector control *7 )
Control: Starting torque: PM motorThe following is the specifications for the ND rating. 50 % (current synchronization operation)
Control: Torque boostManual torque boost (induction motor only)
Control: Acceleration/deceleration time setting0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash countermeasures acceleration/deceleration modes are available.
Control: DC injection brake: Induction motorOperation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable
Control: DC injection brake: PM motorOperation time (0 to 10 s) variable. Operating voltage (operating current) fixed.
Control: Stall prevention operation levelActivation range of stall prevention operation (SLD rating : 0 to 120 %, LD rating : 0 to 150 %, ND rating : 0 to 220 %, HD rating : 0 to 280 %). Whether to use the stall prevention or not can be selected. (V/F control, Advanced magnetic flux vector control)
Control: Torque limit levelTorque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control *7 , PM sensorless vector control)
Operation: Frequency setting signal: Number of analog input3
Operation: Frequency setting signal: Specification of analog inputTerminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V/-5 to +5 V
Operation: Frequency setting signal: Digital inputInput using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed).
Operation: Start signalForward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected.
Operation: Input signal: Number of input signal (Contact input)12
Operation: Input signal: Pulse train input100 k pulses/s
Operation: Input signal: Input terminal function selectable signalLow-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Selection of automatic restart after instantaneous power failure/flying start, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed us
Operation: Operational functionMaximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Electronic bypass sequence, Remote
Operation: Output signal: Number of output signal (Open collector output)5
Operation: Output signal: Number of output signal (Relay output)2
Operation: Output signal: Output terminal function selectable signalInverter running, Up to frequency, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collector.
Operation: Output signal: Pulse train output (FM type inverter)50 k pulses/s
Indication: For indication on external meters: Number of output signal for indication on external meters2
Indication: For indication on external meters: Pulse train output (FM type inverter)Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM terminal function selection.
Indication: For indication on external meters: Voltage outputMax. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection.
Protective/warning function: Protective functionOvercurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio
Protective/warning function: Warning functionFan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU stop, Speed limit indication *10 , Parameter copy, Maintenance timer *10 , USB host error, Home position return setting error *10 , Home position return uncompleted *10 , Home position return parameter setting error *10 , Operation panel lock *10 , Password locked *10 , Parame
Environment: Surrounding air temperature-10 °C to +50 °C (non-freezing) (LD, ND ratings) -10 °C to +40 °C (non-freezing) (SLD, HD ratings)
Environment: Surrounding air humidity95 % RH or less (non-condensing)
Environment: Storage temperature *9-20 °C to +65 °C
Environment: AmbienceIndoors (free from corrosive gas, flammable gas, oil mist, dust and dirt)
Environment: Altitude/vibrationMaximum 2500 m *11 , 2.9 m/s 2 or less at 10 to 55 Hz in X, Y, and Z directions
NetworkRS-485 : Mitsubishi inverter protocol Ethernet : CC-Link IE Field Network Basic, MODBUS/TCP Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1

Downloads & documentation

Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.

Data sheets & manuals

FR-A862-E (SEPARATED CONVERTER TYPE) INSTRUCTION MANUAL (HARDWARE) (IB-0600639ENG-C)PDF · 4.60MB
FR-A800-E/F800-E ETHERNET FUNCTION MANUAL (IB-0600628ENG-D)PDF · 1.72MB
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-A860-03360-E1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A860-03360-E1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A860-03360-E1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A860-04420-1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A860-04420-1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A860-04420-1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A860-04420-E1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A860-04420-E1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A860-04420-E1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A862-05450-1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A862-05450-1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A862-05450-1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A862-06470-1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A862-06470-1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A862-06470-1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A862-06470-E1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A862-06470-E1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A862-06470-E1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A862-08500-1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A862-08500-1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A862-08500-1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A862-08500-E1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A862-08500-E1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A862-08500-E1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote