FR-A846-00620-1-60C3 Mitsubishi FREQROL inverter FR-A800
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi FREQROL inverter – FREQROL-A800 |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FR-A846-00620-1-60C3 be shipped?
FR-A846-00620-1-60C3 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FR-A846-00620-1-60C3 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FR-A846-00620-1-60C3 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-A846-00620-1-60C3, subject to availability and destination.
The Mitsubishi Electric FR-A846-00620-1-60C3 is a FR-A800 in the FREQROL inverter. cULus CE(EMC) CE(LVD). Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | FREQROL inverter |
| Category | FR-A800 |
| Outline | cULus CE(EMC) CE(LVD) |
Specifications
| Series | FR-A800 |
| Type | Three-phase 400 V class IP55 compatible model RS-485 model |
| Model name | FR-A846-00620-1-60C3 |
| Inverter capacity (kW) | 22.0 |
| Applicable motor capacity (kW) *1: LD | 30.0 |
| Applicable motor capacity (kW) *1: ND | 22.0 |
| Output: Rated capacity (kVA) *2: LD | 43.0 |
| Output: Rated capacity (kVA) *2: ND | 34.0 |
| Output: Rated current (A): LD | 57.0 |
| Output: Rated current (A): ND | 44.0 |
| Output: Overload current rating *3: LD | 120 % 60 s, 150 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C |
| Output: Overload current rating *3: ND | 150 % 60 s, 200 % 3 s (inverse-time characteristics) at surrounding air temperature of 40 °C |
| Output: Voltage *4 | Three-phase 380 to 500 V |
| Output: Regenerative braking: Maximum brake torque (ND reference) | 10 % torque/continuous |
| Power supply: Rated input AC voltage and frequency | Three-phase 380 to 500 V, 50/60 Hz *7 |
| Power supply: Permissible AC voltage fluctuation | 323 to 550 V, 50/60 Hz |
| Power supply: Permissible frequency fluctuation | ±5 % |
| Power supply: Rated input current (A) without DC reactor *5: LD | 57.0 |
| Power supply: Rated input current (A) without DC reactor *5: ND | 44.0 |
| Power supply: Power supply capacity (kVA) without DC reactor *5: LD | 43.0 |
| Power supply: Power supply capacity (kVA) without DC reactor *5: ND | 34.0 |
| Protective structure: IEC 60529 | IP55 *9 |
| Protective structure: UL 50 | UL Type12 *8 |
| Cooling system | Forced air + internal fan |
| DC reactor | Built-in |
| Approx. mass (kg) | 59.0 |
| Control: Control method: Common | Soft-PWM control/High carrier frequency PWM control |
| Control: Control method: Induction motor | Selectable among V/F control, Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *10 |
| Control: Control method: PM motor | Selectable among PM sensorless vector control, and Vector control *10 |
| Control: Output frequency range: Induction motor | 0.2 to 590 Hz (The upper-limit frequency is 400 Hz under Advanced magnetic flux vector control, Real sensorless vector control, and Vector control *10 .) |
| Control: Output frequency range: PM motor | 0.2 to 400 Hz (not operable at a frequency higher than the maximum motor frequency) |
| Control: Frequency setting and resolution: Analog input | 0.015 Hz/60 Hz at 0 to 10 V/12 bits (terminals 2 and 4) 0.03 Hz/60 Hz at 0 to 5 V/11 bits or 0 to 20 mA/11 bits (terminals 2 and 4), at 0 to ±10 V/12 bits (terminal 1) 0.06 Hz/60 Hz at 0 to ±5 V/11 bits (terminal 1) |
| Control: Frequency setting and resolution: Digital input | 0.01 Hz |
| Control: Frequency accuracy: Analog input | Within ±0.2 % of the maximum output frequency (25 °C ±10 °C) |
| Control: Frequency accuracy: Digital input | 0.01 % or less of the set output frequency |
| Control: Voltage/frequency characteristics | Base frequency can be set from 0 to 590 Hz. Constant-torque/variable-torque pattern or adjustable 5 points V/F can be selected. |
| Control: Starting torque: Induction motor | The following is the specifications for the ND rating. 30 % or less at 1 Hz, 30 % at 3 Hz, 80 % at 6 Hz (V/F control) 150 % at 0.5 Hz (Advanced magnetic flux vector control) 200 % at 0.3 Hz (0.4K to 3.7K), 150 % at 0.3 Hz (5.5K or higher) (Real sensorless vector control) 200 % at 0 Hz (0.4K to 3.7K), 150 % at 0 Hz (5.5K or higher) (Vector control *10 ) |
| Control: Starting torque: PM motor | The following is the specifications for the ND rating. 50 % (current synchronization operation) 200 % (when used with MM-CF, 200 % for the 1.5 kW or lower, and 150 % for the 2.0 kW or higher) (high frequency superposition control) |
| Control: Torque boost | Manual torque boost (induction motor only) |
| Control: Acceleration/deceleration time setting | 0 to 3600 s (acceleration and deceleration can be set individually), linear or S-pattern acceleration/deceleration mode, backlash countermeasures acceleration/deceleration modes are available. |
| Control: DC injection brake: Induction motor | Operation frequency (0 to 120 Hz), operation time (0 to 10 s), operation voltage (0 to 30 %) variable |
| Control: DC injection brake: PM motor | Operation time (0 to 10 s) variable. Operating voltage (operating current) fixed. |
| Control: Stall prevention operation level | Activation range of stall prevention operation (LD rating : 0 to 150 %, ND rating : 0 to 220 %). Whether to use the stall prevention or not can be selected. (V/F control, Advanced magnetic flux vector control) |
| Control: Torque limit level | Torque limit value can be set (0 to 400 % variable). (Real sensorless vector control, Vector control *10 , PM sensorless vector control) |
| Operation: Frequency setting signal: Number of analog input | 3 |
| Operation: Frequency setting signal: Specification of analog input | Terminals 2 and 4 : 0 to 10 V/0 to 5 V/4 to 20 mA (0 to 20 mA) Terminal 1 : -10 to +10 V/-5 to +5 V |
| Operation: Frequency setting signal: Digital input | Input using the setting dial of the operation panel or parameter unit. Input of four-digit BCD (Binary-coded decimal) or 16-bit binary (when the option FR-A8AX is installed). |
| Operation: Start signal | Forward and reverse rotation or start signal automatic self-holding input (3-wire input) can be selected. |
| Operation: Input signal: Number of input signal (Contact input) | 12 |
| Operation: Input signal: Pulse train input | 100 k pulses/s |
| Operation: Input signal: Input terminal function selectable signal | Low-speed operation command, Middle-speed operation command, High-speed operation command, Second function selection, Terminal 4 input selection, Jog operation selection, Selection of automatic restart after instantaneous power failure/flying start, Output stop, Start self-holding selection, Forward rotation command, Reverse rotation command, Inverter reset The signal to be input can be changed us |
| Operation: Operational function | Maximum and minimum frequency settings, Multi-speed operation, Acceleration/deceleration pattern, Thermal protection, DC injection brake, Starting frequency, JOG operation, Output stop (MRS), Stall prevention, Regeneration avoidance, Increased magnetic excitation deceleration, DC feeding, Frequency jump, Rotation display, Automatic restart after instantaneous power failure, Electronic bypass seque |
| Operation: Output signal: Number of output signal (Open collector output) | 5 |
| Operation: Output signal: Number of output signal (Relay output) | 2 |
| Operation: Output signal: Output terminal function selectable signal | Inverter running, Up to frequency, Instantaneous power failure/undervoltage, Overload warning, Output frequency detection, Fault The signal to be output can be changed using Pr.190 to Pr.196 (Output terminal function selection). Fault codes (4 bits) of the inverter can be output from the open collector. |
| Operation: Output signal: Pulse train output (FM type inverter) | 50 k pulses/s |
| Indication: For indication on external meters: Number of output signal for indication on external meters | 2 |
| Indication: For indication on external meters: Pulse train output (FM type inverter) | Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection. |
| Indication: For indication on external meters: Current output (CA type inverter) | Max. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection. |
| Indication: For indication on external meters: Voltage output | Max. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection. |
| Indication: Operation panel: Status monitoring | Output frequency, output current, output voltage, and frequency setting value are monitored. The item for monitoring can be changed using Pr.52 Operation panel main monitor selection. |
| Indication: Operation panel: Fault monitoring | When a protective function is activated, a fault indication is displayed and the output voltage, output current, output frequency, cumulative energization time, date (year, month, day) and time at the occurrence of the fault are stored. Each fault is recorded and the last 8 records can be displayed. |
| Protective/warning function: Protective function | Overcurrent trip during acceleration, Overcurrent trip during constant speed, Overcurrent trip during deceleration or stop, Regenerative overvoltage trip during acceleration, Regenerative overvoltage trip during constant speed, Regenerative overvoltage trip during deceleration or stop, Inverter overload trip (electronic thermal relay function), Motor overload trip (electronic thermal relay functio |
| Protective/warning function: Warning function | Fan alarm, Stall prevention (overcurrent), Stall prevention (overvoltage), Electronic thermal relay function pre-alarm, PU stop, Speed limit indication *12 , Safety stop, Maintenance timer *12 , USB host error, Home position return setting error *12 , Home position return uncompleted *12 , Home position return parameter setting error *12 , Operation panel lock *12 , Password locked *12 , Parameter |
| Environment: Surrounding air temperature | -10 °C to +40 °C (non-freezing) |
| Environment: Surrounding air humidity | 95 % RH or less (non-condensing) |
| Environment: Storage temperature *11 | -20 °C to +65 °C |
| Environment: Ambience | Indoors (free from corrosive gas, flammable gas, oil mist, dust and dirt) |
| Environment: Altitude/vibration | Maximum 2500 m *15 , 5.9 m/s 2 *14 or less at 10 to 55 Hz in X, Y, and Z directions |
| Network | RS-485 : Mitsubishi inverter protocol, MODBUS RTU Option unit : CC-Link IE TSN, CC-Link IE Field Network, CC-Link, SSCNETIII(/H), DeviceNet, PROFIBUS-DPV0, FL remote, EtherCAT, EtherNet/IP, PROFINET, PROFIBUS-DPV1 |
Downloads & documentation
Official documents from Mitsubishi Electric (Factory Automation), downloaded directly from the manufacturer.
Data sheets & manuals
More Mitsubishi Electric (Factory Automation) parts
Available on requestFR-A846-00470-2-60L2 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00470-E1-60C3 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00470-E2-60C2 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00470-E2-60L2 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00620-2-60C2 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00620-2-60L2 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00620-E1-60C3 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A846-00620-E2-60C2 Mitsubishi FREQROL inverter FR-A800