Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi FREQROL inverter – Option |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FR-A842-10940-2-60(Converter) be shipped?
FR-A842-10940-2-60(Converter) is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FR-A842-10940-2-60(Converter) in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FR-A842-10940-2-60(Converter) and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-A842-10940-2-60(Converter), subject to availability and destination.
The Mitsubishi Electric FR-A842-10940-2-60(Converter) is a braking option in the FREQROL inverter. high power factor converter (FR-A842). Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | FREQROL inverter |
| Category | Braking option |
| Outline | high power factor converter (FR-A842) |
Specifications
| Series | Option |
| Category | high power factor converter unit |
| Type | Three-phase 400 V class Standard type |
| Model name | FR-A842-10940-2-60(Converter) |
| Applicable inverter capacity (kW) | 450.0 |
| Rated output capacity (kW) *1 | 536.0 |
| Rated voltage *2 *3 | Three-phase 380 to 500 V, 50/60 Hz *6 *7 |
| Rated voltage | 806.0 |
| Overload current rating *4 | 150 % 60 s |
| Rated input AC voltage/ frequency | 323 to 506 V, 50/60 Hz |
| Permissible frequency fluctuation | ±5 % |
| Input power factor | 0.99 or more (when load ratio is 100 %) |
| Power supply capacity (kVA) | 652.0 |
| Protective structure *5 | IP00 |
| Cooling system | Forced air |
| Approx. mass (kg) | 243.0 |
| Control specifications: Control method | PWM control |
| Control specifications: Power supply frequency range | 50 to 60 Hz |
| Control specifications: Current limit level | Current limit value selectable (0 to 220 % variable) |
| Operation specifications: Number of input signal (Contact input) | 12 |
| Operation specifications: Input terminal function selectable signal | The following signals can be assigned to Pr.178 to Pr.189 (Input terminal function selection): Converter stop, External thermal relay input, Reactor overheat protection, Inrush current limit resistor overheat detection, and Reset. |
| Operation specifications: Number of output signal (Open collector output) | 4 |
| Operation specifications: Number of output signal (Relay output) | 1 |
| Operation specifications: Output terminal function selectable signal | The following signals can be assigned to Pr.192 to Pr.194 or Pr.196 (Output terminal function selection): Inverter run enable, Converter reset, Instantaneous power failure, Overload warning, Converter running, Output voltage match, Power supply phase detection, Electronic thermal O/L relay pre-alarm, Instantaneous power failure detection hold, Fan fault output, Heat sink overheat pre-alarm, Regene |
| Operation specifications: Status monitoring | The following signals can be assigned to Pr.192 to Pr.194 or Pr.196 (Output terminal function selection): Inverter run enable, Converter reset, Instantaneous power failure, Overload warning, Converter running, Output voltage match, Power supply phase detection, Electronic thermal O/L relay pre-alarm, Instantaneous power failure detection hold, Fan fault output, Heat sink overheat pre-alarm, Regene |
| Operation specifications: For indication on external meters: Number of output signal for indication on external meters | 2 |
| Operation specifications: For indication on external meters: Pulse train output (FM type inverter) | Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection. |
| Operation specifications: For indication on external meters: Current output (CA type inverter) | Max. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection. |
| Operation specifications: For indication on external meters: Voltage output | Max. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection. |
| Operation panel (FR-DU08) Parameter unit (FR-PU07): Status monitoring | Power supply frequency, input current, input voltage, bus voltage, fault display, electronic thermal relay function load factor, input power, input power (with regenerative display), cumulative energization time, cumulative energy, input terminal status *8 , output terminal status *8 , and control circuit temperature. |
| Operation panel (FR-DU08) Parameter unit (FR-PU07): Fault monitoring | When a protective function is activated, a fault indication is displayed, and the latest monitored value of input voltage, input current, bus voltage, cumulative energization time are recorded. The last eight fault records are stored. |
| Operation panel (FR-DU08) Parameter unit (FR-PU07): Interactive guidance | Help function for operation guide *9 . |
| Protective/warning function: Protective function | Overcurrent trip, Overvoltage trip, Overload trip (electronic thermal relay function), Heat sink overheat, Instantaneous power failure, Undervoltage, Input phase loss, Input power supply fault, External thermal relay operation *11 , Parameter storage device fault, PU disconnection *11 , Retry count excess *11 , Inverter/converter switching fault, CPU fault, Operation panel power supply short circu |
| Protective/warning function: Warning function | Fan alarm, Overload signal detection, Electronic thermal O/L relay pre-alarm, PU stop, Maintenance timer 1 to 3 *11 , Parameter write error, Copy operation fault, Operation panel lock, Power supply not detected,24 V external power supply operation |
| Environment: Surrounding air temperature | -20 °C to +50 °C (non-freezing) |
| Environment: Surrounding air humidity | With circuit board coating: 95 % RH or less (non-condensing) Without circuit board coating: 90 % RH or less (non-condensing) |
| Environment: Storage temperature *10 | -20 °C to +65 °C |
| Environment: Ambience | Indoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.) |
| Environment: Altitude/vibration | 2500 m or less *12 , 2.9 m / s 2 or less at 10 to 55 Hz (directions of X, Y, Z axes) |
More Mitsubishi Electric (Factory Automation) parts
Available on requestFR-A842-09620-E2-60 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A842-10940-1-60 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A842-10940-1-U6 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A842-10940-2-60 Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A842-10940-2-60CRN Mitsubishi FREQROL inverter FR-A800 Plus
Available on requestFR-A842-10940-2-60P Mitsubishi FREQROL inverter FR-A800
Available on requestFR-A842-10940-2-60R2R Mitsubishi FREQROL inverter FR-A800 Plus
Available on requestFR-A842-10940-E1-60 Mitsubishi FREQROL inverter FR-A800