Available on request

FR-A842-07700-2-60(Converter) Mitsubishi FREQROL inverter Braking option

MPN: FR-A842-07700-2-60(Converter) · Brand: Mitsubishi Electric (Factory Automation)
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryMitsubishi FREQROL inverter – Option
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can FR-A842-07700-2-60(Converter) be shipped?

FR-A842-07700-2-60(Converter) is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FR-A842-07700-2-60(Converter) in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FR-A842-07700-2-60(Converter) and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FR-A842-07700-2-60(Converter), subject to availability and destination.

The Mitsubishi Electric FR-A842-07700-2-60(Converter) is a braking option in the FREQROL inverter. high power factor converter (FR-A842). Specifications and manuals below are Mitsubishi Electric's own data.

Specifications

Product

SeriesFREQROL inverter
CategoryBraking option
Outlinehigh power factor converter (FR-A842)

Specifications

SeriesOption
Categoryhigh power factor converter unit
TypeThree-phase 400 V class Standard type
Model nameFR-A842-07700-2-60(Converter)
Applicable inverter capacity (kW)315.0
Rated output capacity (kW) *1375.0
Rated voltage *2 *3Three-phase 380 to 500 V, 50/60 Hz *6 *7
Rated voltage564.0
Overload current rating *4150 % 60 s
Rated input AC voltage/ frequency323 to 506 V, 50/60 Hz
Permissible frequency fluctuation±5 %
Input power factor0.99 or more (when load ratio is 100 %)
Power supply capacity (kVA)456.0
Protective structure *5IP00
Cooling systemForced air
Approx. mass (kg)163.0
Control specifications: Control methodPWM control
Control specifications: Power supply frequency range50 to 60 Hz
Control specifications: Current limit levelCurrent limit value selectable (0 to 220 % variable)
Operation specifications: Number of input signal (Contact input)12
Operation specifications: Input terminal function selectable signalThe following signals can be assigned to Pr.178 to Pr.189 (Input terminal function selection): Converter stop, External thermal relay input, Reactor overheat protection, Inrush current limit resistor overheat detection, and Reset.
Operation specifications: Number of output signal (Open collector output)4
Operation specifications: Number of output signal (Relay output)1
Operation specifications: Output terminal function selectable signalThe following signals can be assigned to Pr.192 to Pr.194 or Pr.196 (Output terminal function selection): Inverter run enable, Converter reset, Instantaneous power failure, Overload warning, Converter running, Output voltage match, Power supply phase detection, Electronic thermal O/L relay pre-alarm, Instantaneous power failure detection hold, Fan fault output, Heat sink overheat pre-alarm, Regene
Operation specifications: Status monitoringThe following signals can be assigned to Pr.192 to Pr.194 or Pr.196 (Output terminal function selection): Inverter run enable, Converter reset, Instantaneous power failure, Overload warning, Converter running, Output voltage match, Power supply phase detection, Electronic thermal O/L relay pre-alarm, Instantaneous power failure detection hold, Fan fault output, Heat sink overheat pre-alarm, Regene
Operation specifications: For indication on external meters: Number of output signal for indication on external meters2
Operation specifications: For indication on external meters: Pulse train output (FM type inverter)Max. 2.4 kHz via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection.
Operation specifications: For indication on external meters: Current output (CA type inverter)Max. 20 mA DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.54 FM/CA terminal function selection.
Operation specifications: For indication on external meters: Voltage outputMax. 10 V DC via one terminal (for the indication of inverter output frequency). The item for monitoring can be changed using Pr.158 AM terminal function selection.
Operation panel (FR-DU08) Parameter unit (FR-PU07): Status monitoringPower supply frequency, input current, input voltage, bus voltage, fault display, electronic thermal relay function load factor, input power, input power (with regenerative display), cumulative energization time, cumulative energy, input terminal status *8 , output terminal status *8 , and control circuit temperature.
Operation panel (FR-DU08) Parameter unit (FR-PU07): Fault monitoringWhen a protective function is activated, a fault indication is displayed, and the latest monitored value of input voltage, input current, bus voltage, cumulative energization time are recorded. The last eight fault records are stored.
Operation panel (FR-DU08) Parameter unit (FR-PU07): Interactive guidanceHelp function for operation guide *9 .
Protective/warning function: Protective functionOvercurrent trip, Overvoltage trip, Overload trip (electronic thermal relay function), Heat sink overheat, Instantaneous power failure, Undervoltage, Input phase loss, Input power supply fault, External thermal relay operation *11 , Parameter storage device fault, PU disconnection *11 , Retry count excess *11 , Inverter/converter switching fault, CPU fault, Operation panel power supply short circu
Protective/warning function: Warning functionFan alarm, Overload signal detection, Electronic thermal O/L relay pre-alarm, PU stop, Maintenance timer 1 to 3 *11 , Parameter write error, Copy operation fault, Operation panel lock, Power supply not detected,24 V external power supply operation
Environment: Surrounding air temperature-20 °C to +50 °C (non-freezing)
Environment: Surrounding air humidityWith circuit board coating: 95 % RH or less (non-condensing) Without circuit board coating: 90 % RH or less (non-condensing)
Environment: Storage temperature *10-20 °C to +65 °C
Environment: AmbienceIndoors (without corrosive gas, flammable gas, oil mist, dust and dirt, etc.)
Environment: Altitude/vibration2500 m or less *12 , 2.9 m / s 2 or less at 10 to 55 Hz (directions of X, Y, Z axes)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Mitsubishi Electric (Factory Automation) parts

FR-A840M-04540-E2-60C2 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A840M-04540-E2-60C2 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A840M-04540-E2-60C2 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A842-07700-1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A842-07700-1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-1-U6 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A842-07700-1-U6 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A842-07700-1-U6 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-2-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A842-07700-2-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A842-07700-2-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-2-60CRN Mitsubishi FREQROL inverter FR-A800 PlusAvailable on requestFR-A842-07700-2-60CRN Mitsubishi FREQROL inverter FR-A800 Plus
MPN: FR-A842-07700-2-60CRN · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-2-60R2R Mitsubishi FREQROL inverter FR-A800 PlusAvailable on requestFR-A842-07700-2-60R2R Mitsubishi FREQROL inverter FR-A800 Plus
MPN: FR-A842-07700-2-60R2R · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-E1-60 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A842-07700-E1-60 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A842-07700-E1-60 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote
FR-A842-07700-E1-U6 Mitsubishi FREQROL inverter FR-A800Available on requestFR-A842-07700-E1-U6 Mitsubishi FREQROL inverter FR-A800
MPN: FR-A842-07700-E1-U6 · Mitsubishi Electric (Factory Automation)
Price on request
Request a quote