High-accuracy temperature/voltage measurement unit. NR-TH08. Series: Multi-input Data Logger. Series code: NR-X series

Specifications

Specifications

Model NameHigh-accuracy temperature/voltage measurement unit
Model CodeNR-TH08
Series TitleMulti-input Data Logger
Series CodeNR-X series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117TH08&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117TH08
Manuals URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117TH08
ModelNR-TH08 *1
TypeHigh-accuracy temperature/voltage measurement unit
Input methodFloating unbalanced input, channels insulated from each other, CH inputs insulated from other units (PC),channels not insulated from each other for resistance thermometers
Number of channelsInput: 8 *2
Measurement cycleFastest sampling cycle: 100 ms (A/D integration time: 2 ms) to 1 h
A/D converting systemDelta-sigma method
A/D resolution24 bit
A/D integration time2 ms, 16.7 ms, 20 ms
Input typeVoltage: ±50 V, ±10 V, ±5 V, ±1 V, ±0.5 V, ±0.1 V; Thermocouple; K, J, E, T, R, S, B, N, C;Resistance thermometer: Pt100, JPt100 3-line type; Specified current: 1 mA
Measurement range - ±50 VMeasurable range: −55.00 to +55.00 VMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digitsDisplay resolution: 10 mV
Measurement range - ±10 VMeasurable range: −11.000 to +11.000 VMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digitsDisplay resolution: 1 mV
Measurement range - ±5 VMeasurable range: −5.500 to +5.500 VMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digitsDisplay resolution: 1 mV
Measurement range - ±1 VMeasurable range: −1.1000 to +1.1000 VMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digitsDisplay resolution: 0.1 mV
Measurement range - ±500 mVMeasurable range: −550.0 to +550.0 mVMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digitsDisplay resolution: 0.1 mV
Measurement range - ±100 mVMeasurable range: −110.00 to +110.00 mVMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±2 digitsDisplay resolution: 0.01 mV
Measurement range - KMeasurable range: −100 to +1372°C -148°F to +2501.6°F, −200 to −100°C -328°F to -148°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F, ±0.05% of rdg ±0.9°C ±1.6°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - JMeasurable range: −100 to +1200°C -148°F to +2192°F, −200 to −100°C -328°F to -148°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F, ±0.05% of rdg ±0.8°C ±1.4°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - EMeasurable range: −100 to +1000°C -148°F to +1832°F, −200 to −100°C -328°F to -148°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°F, ±0.05% of rdg ±0.8°C ±1.4°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - TMeasurable range: −100 to +400°C -148°F to +752°F, −200 to −100°C -328°F to -148°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.5°C ±0.9°F, ±0.05% of rdg ±0.8°C ±1.4°FDisplay resolution: 0.01°C 0.02°F*3
Measurement range - NMeasurable range: 0 to 1300°C 32°F to 2372°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.6°C ±1.1°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - CMeasurable range: 1500 to 2315°C 2732°F to 4199°F, 0 to 1500°C 32°F to 2732°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±1.1°C ±2.0°F, ±0.05% of rdg ±0.8°C ±1.4°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - RMeasurable range: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.8°C ±1.4°F, ±0.05% of rdg ±1.6°C ±2.9°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - SMeasurable range: 300 to 1768°C 572°F to 3214.4°F, 0 to 300°C 32°F to 572°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±0.9°C ±1.6°F, ±0.05% of rdg ±1.6°C ±2.9°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - BMeasurable range: 400 to 600°C 752°F to 1112°F, 600 to 1820°C 1112°F to 3308°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.05% of rdg ±1.7°C ±3.1°F, ±0.05% of rdg ±1.0°C ±1.8°FDisplay resolution: 0.05°C 0.09°F*3
Measurement range - Pt100Measurable range: −200 to +660°C -328°F to +1220°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.1% of rdg ±0.3°C ±0.5°FDisplay resolution: 0.02°C 0.04°F*4
Measurement range - JPt100Measurable range: −200 to +510°C -328°F to +950°FMeasurement accuracy (A/D integration time: 16.7 ms, 20 ms): ±0.1% of rdg ±0.3°C ±0.5°FDisplay resolution: 0.02°C 0.04°F*4
Reference contact compensationSwitchable between internal and external (individual unit setting, 0°C 32°F for external)
Reference contact compensation accuracy±0.7°C ±1.3°F (23°C ±2°C 73.4°F ±3.6°F, at input terminal temperature equilibrium)
Maximum input voltage±60 V (rated)
Input impedance - Thermocouple, Voltage: 5 V range or lower10 MΩ or more
Input impedance - Voltage: 50 V, 10 V rangeApprox. 1 MΩ
Withstand voltage - Measurement input terminal - System bus1500 VAC (50/60 Hz) for 1 minute
Withstand voltage - Mutually between measurement input terminals120 Vp-p AC/DC
Input signal source resistance - Voltage/thermocouple2 kΩ or less
Input signal source resistance - Resistance thermometer10 Ω or less per line (three lines must be equal)
Thermocouple burnoutWire breakage detected in the thermocouple range by applying 1 μA of current
Burnout detection frequencyDetected in the measurement cycle
Buffer memory200k data
Warm up time30 minutes or more*5
Rating1.2 W or less
Environmental resistance - Ambient temperature0 to +40°C 32°F to 104°F
Environmental resistance - Relative humidity10 to 85% RH (no condensation)
WeightApprox. 230 g 8.12 oz (including approx. 100 g 3.53 oz for the OP-51582 (NR-TH08 terminal block))

NR-TH08: frequently asked questions

When can NR-TH08 be shipped?

NR-TH08 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NR-TH08 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NR-TH08 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NR-TH08, subject to availability and destination.

More Keyence parts

Keyence NR-PM01 – Power Monitor. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-PM01

Power Monitor. . Series: Multi-input Data Logger. Series…

Keyence NR-PMC10 – Power Monitor. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-PMC10

Power Monitor. . Series: Multi-input Data Logger. Series…

Keyence NR-ST04 – Strain measurement unit. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-ST04

Strain measurement unit.

Keyence NR-U5 – AC adapter. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-U5

AC adapter. . Series: Multi-input Data Logger. Series code…

Keyence NR-X100W – Master data collection unit. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-X100W

Master data collection unit.

Keyence NR-XB1A – Lithium Ion Battery. . Series: Wide Area CMM. Series code: WM-6000 series
Keyence
NR-XB1A

Lithium Ion Battery. . Series: Wide Area CMM. Series code…

Keyence NR-TH08Price and lead time confirmed within 1 business day
Request a Quote