Keyence NR-CA04

Acceleration measurement unit. . Series: Multi-input Data Logger. Series code: NR-X series

MPN
NR-CA04
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare Keyence parts? We buy surplus →

What is the Keyence NR-CA04?

Acceleration measurement unit. NR-CA04. Series: Multi-input Data Logger. Series code: NR-X series

Specifications

Specifications

Model NameAcceleration measurement unit
Model CodeNR-CA04
Series TitleMulti-input Data Logger
Series CodeNR-X series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57362&dlModelId=PM_117CA04&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=cd&modelId=PM_117CA04
Manuals URLhttps://www.keyence.com/products/daq/data-loggers/nr-x/downloads/?mode=ma&modelId=PM_117CA04
ModelNR-CA04 *1
TypeAcceleration measurement unit
Input methodCharge output sensor input / Single-end input, channels not insulated from each other; input channels switchable between insulated and not insulated from other units (PC)
Number of channels4 ch*2
Measurement cycleMaximum sampling cycle: 10 µs (100 kHz) to 60 s
A/D converting systemDelta-sigma method, simultaneous sampling of all channels
A/D resolution24 bit
Low pass filterPASS, 100 Hz, 1 kHz, 10 kHz (−12 dB/oct)
Maximum input rating±25 V
Withstand voltage300 VAC (50/60 Hz) for 1 minute
Connector formatCharge output sensor input: Miniature (10-32UNF); Voltage input/output (built-in pre-amplifier)Sensor input: Non-insulated BNC connector
Input impedance100 kΩ ±1%, approx. 38 pF
Input type - Sensor input±50000 m/s2 ±164042.0 ft/s2, ±20000 m/s2 ±65616.8 ft/s2, ±10000 m/s2 ±32808.4 ft/s2, ±5000 m/s2 ±16404.2 ft/s2,±2000 m/s2 ±6561.7 ft/s2, ±1000 m/s2 ±3280.8 ft/s2, ±500 m/s2 ±1640.4 ft/s2, ±200 m/s2 ±656.2 ft/s2,±100 m/s2 ±328.1 ft/s2, ±50.0 m/s2 ±164.0 ft/s2, ±20.0 m/s2 ±65.6 ft/s2, ±10.0 m/s2 ±32.8 ft/s2, ±5.00 m/s2 ±16.4 ft/s2,±2.00 m/s2 ±6.6 ft/s2, ±1.00 m/s2 ±3.3 ft/s2 (with acceleration (unit setting: m/s2 ft/s2))
Input type - Voltage input±10 V, ±5 V, ±2 V, ±1 V, ±500 mV, ±200 mV, ±100 mV, ±50 mV
Input coupling - Sensor inputCharge output / Voltage output (built-in pre-amplifier) / Charge output - RMS /Voltage output (built-in pre-amplifier) - RMS
Input coupling - Voltage inputAC/DC/AC-RMS/DC-RMS
Input frequency band - Electric charge output type1.5 Hz (−3 dB typ.) to 45 kHz (±0.5 dB)
Input frequency band - Voltage output type (with built-in preamplifier) AC/AC-RMS1.0 Hz (−3 dB typ.) to 45 kHz (±0.5 dB)
Input frequency band - DC/DC-RMS45 kHz DC max. (±0.5 dB)
Measurement accuracy - Electric charge output type±0.9% of F.S. at [Sensor sensitivity] × [Setting range] ≥ 20 pC
Measurement accuracy - Voltage output type (with built-in preamplifier)±0.25% of F.S. at [Sensor sensitivity] × [Setting range] ≥ 200 mV
Measurement accuracy - Voltage±10 V to ±100 mV range: ±0.1% of F.S.±50 mV range: ±0.15% of F.S., LPF: 100 Hz
Measurement range - ±10 VMeasurable range: −11.0000 to +11.0000 V, Display resolution: 0.5 mV*3
Measurement range - ±5 VMeasurable range: −5.5000 to +5.5000 V, Display resolution: 0.2 mV*3
Measurement range - ±2 VMeasurable range: −2.2000 to +2.2000 V, Display resolution: 100 μV*3
Measurement range - ±1 VMeasurable range: −1.1000 to +1.1000 V, Display resolution: 50 μV*3
Measurement range - ±500 mVMeasurable range: −550.00 to +550.00 mV, Display resolution: 20 μV*3
Measurement range - ±200 mVMeasurable range: −220.00 to +220.00 mV, Display resolution: 10 μV*3
Measurement range - ±100 mVMeasurable range: −110.000 to +110.000 mV, Display resolution: 5 μV*3
Measurement range - ±50 mVMeasurable range: −55.000 to +55.000 mV, Display resolution: 2 μV*3
Measurement range - ±50000 m/s2 ±164042.0 ft/s2Measurable range: −55000 to +55000 m/s2 -180446.2 ft/s2 to +180446.2 ft/s2, Display resolution: 2 m/s2 6.6 ft/s2*3
Measurement range - ±20000 m/s2 ±65616.8 ft/s2Measurable range: −22000 to +22000 m/s2 -72178.5 ft/s2 to +72178.5 ft/s2, Display resolution: 1 m/s2 3.3 ft/s2*3
Measurement range - ±10000 m/s2 ±32808.4 ft/s2Measurable range: −11000 to +11000 m/s2 -36089.2 ft/s2 to +36089.2 ft/s2, Display resolution: 0.5 m/s2 1.6 ft/s2*3
Measurement range - ±5000 m/s2 ±16404.2 ft/s2Measurable range: −5500 to +5500 m/s2 -18044.6 ft/s2 to +18044.6 ft/s2, Display resolution: 0.2 m/s2 0.7 ft/s2*3
Measurement range - ±2000 m/s2 ±6561.7 ft/s2Measurable range: −2200 to +2200 m/s2 -7217.8 ft/s2 to +7217.8 ft/s2, Display resolution: 0.1 m/s2 0.3 ft/s2*3
Measurement range - ±1000 m/s2 ±3280.8 ft/s2Measurable range: −1100 to +1100 m/s2 -3608.9 ft/s2 to +3608.9 ft/s2, Display resolution: 0.05 m/s2 0.16 ft/s2*3
Measurement range - ±500 m/s2 ±1640.4 ft/s2Measurable range: −550 to +550 m/s2 -1804.5 ft/s2 to +1804.5 ft/s2, Display resolution: 0.02 m/s2 0.07 ft/s2*3
Measurement range - ±200 m/s2 ±656.2 ft/s2Measurable range: −220 to +220 m/s2 -728.1 ft/s2 to +728.1 ft/s2, Display resolution: 0.01 m/s2 0.03 ft/s2*3
Measurement range - ±100 m/s2 ±328.1 ft/s2Measurable range: −110 to +110 m/s2 -360.9 ft/s2 to +360.9 ft/s2, Display resolution: 0.005 m/s2 0.0164 ft/s2*3
Measurement range - ±50 m/s2 ±164.0 ft/s2Measurable range: −55 to +55 m/s2 -180.4 ft/s2 to +180.4 ft/s2, Display resolution: 0.002 m/s2 0.0066 ft/s2*3
Measurement range - ±20 m/s2 ±65.6 ft/s2Measurable range: −22 to +22 m/s2 -72.2 ft/s2 to +72.2 ft/s2, Display resolution: 0.001 m/s2 0.0033 ft/s2*3
Measurement range - ±10 m/s2 ±32.8 ft/s2Measurable range: −11 to +11 m/s2 -36.1 ft/s2 to +36.1 ft/s2, Display resolution: 0.0005 m/s2 0.0016 ft/s2*3
Measurement range - ±5 m/s2 ±16.4 ft/s2Measurable range: −5.5 to +5.5 m/s2 -18.0 ft/s2 to +18.0 ft/s2, Display resolution: 0.0002 m/s2 0.0007 ft/s2*3
Measurement range - ±2 m/s2 ±6.6 ft/s2Measurable range: −2.2 to +2.2 m/s2 -7.2 ft/s2 to +7.2 ft/s2, Display resolution: 0.0001 m/s2 0.0003 ft/s2*3
Measurement range - ±1 m/s2 ±3.3 ft/s2Measurable range: −1.1 to +1.1 m/s2 -3.6 ft/s2 to +3.6 ft/s2, Display resolution: 0.00005 m/s2 0.000164 ft/s2*3
Buffer memory16M data*4
Warm up time30 minutes or more*5
CalculationfunctionSingle integration (velocity conversion), Double integration (displacement conversion)
Sensor input sensitivity setting range - Electric charge output type0.01000 to 999.9 pC/(m/s2)
Sensor input sensitivity setting range - Voltage output type (with built-in preamplifier)0.01000 to 999.9 mV/(m/s2)
Anti-aliasing filterfc = Sampling frequency × 49%, −100 dB at sampling frequency* With a sampling frequency of 1 kS/s or more
Common mode noise reduction ratio80 dB or more (at max. 60 Hz DC) (typ.)
Crosstalk noise reduction ratio100 dB or more (typ.)
High pass filterPASS, 10 Hz (−12 dB/oct)
Disconnection detection functionAvailable (voltage output (built-in pre-amplifier) models only)
Disconnection detection cycleApprox. 200 ms
RMS amplitude accuracySine wave: 20 Hz to 1 kHz, ±0.5% of F.S.Crest factor: 4 or less; Response time: 2600 ms
Residual noise level - Electric charge output type±0.01% of F.S. (typ.) at [Sensor sensitivity] × [Setting range] ≥ 50 pCWith low-pass filter of 1 kHz
Residual noise level - Voltage output type (with built-in preamplifier)±0.05% of F.S. (typ.) at [Sensor sensitivity] × [Setting range] ≥ 200 mVWith low-pass filter of 1 kHz
Residual noise level - Voltage10 to 200 mV range: ±0.01% of F.S. (typ.)100 mV/50 mV range: ±0.02% of F.S. (typ.), with low-pass filter of 1 kHz
Sensor power supply22 V ±10% / 4 mA ±20%
TEDS informationRead sensor information
Rating3.8 W or less
Environmental resistance - Ambient temperature0 to +40°C 32°F to 104°F
Environmental resistance - Relative humidity10 to 85% RH (no condensation)
WeightApprox. 270 g 9.53 oz

NR-CA04: frequently asked questions

When can NR-CA04 be shipped?

NR-CA04 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up NR-CA04 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for NR-CA04 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for NR-CA04, subject to availability and destination.

More Keyence parts

Keyence NQ-P8C10 – M12 female - M12 male power supply cable 10 m. . Series: Network Communication Module. Series code: NQ series
Keyence
NQ-P8C10

M12 female - M12 male power supply cable 10 m.

Keyence NQ-P8C2 – M12 female - M12 male power supply cable 2 m. . Series: Network Communication Module. Series code: NQ series
Keyence
NQ-P8C2

M12 female - M12 male power supply cable 2 m.

Keyence NR-500 – PC direct interface unit. . Series: Multi-input Data Logger. Series code: NR-500 series
Keyence
NR-500

PC direct interface unit.

Keyence NR-C512 – CAN data collection unit. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-C512

CAN data collection unit.

Keyence NR-CF512 – CAN/CAN FD data collection unit. . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-CF512

CAN/CAN FD data collection unit.

Keyence NR-CM01 – Data-Synced Camera (Standard model). . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-CM01

Data-Synced Camera (Standard model).

Keyence NR-CM01L – Data-Synced Camera (Long-range model). . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-CM01L

Data-Synced Camera (Long-range model).

Keyence NR-CM01W – Data-Synced Camera (Wide field of view model). . Series: Multi-input Data Logger. Series code: NR-X series
Keyence
NR-CM01W

Data-Synced Camera (Wide field of view model).

Keyence NR-CA04Price and lead time confirmed within 1 business day