Keyence MP-FG80

Single model G1 (25 A). . Series: Air Quality Multi-Sensor. Series code: MP-F series

MPN
MP-FG80
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Keyence MP-FG80?

Single model G1 (25 A). MP-FG80. Series: Air Quality Multi-Sensor. Series code: MP-F series

Specifications

Specifications

Model NameSingle model G1 (25 A)
Model CodeMP-FG80
Series TitleAir Quality Multi-Sensor
Series CodeMP-F series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157145&dlModelId=PM_276FG80&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/mp-f/downloads/?mode=cd&modelId=PM_276FG80
Manuals URLhttps://www.keyence.com/products/process/flow/mp-f/downloads/?mode=ma&modelId=PM_276FG80
ModelMP-FG80
TypeSingle model
Connection bore diameterG1" (25A)
Supported gasesAir and non-corrosive gases
Supported gas temperature-5 to +50°C, 23 to 122°F
Operating pressure range0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1
Pressure resistance1.5 MPa, 15 bar, 217.5 psi
Flow rate - Detection principleHeat based (mass flow rate)
Flow rate - Rated flow range (normal)12 to 8000 L/min0.7 to 480.0 m3/h 24.72 to 16951.04 ft3/h 0.4 to 282.5 CFM
Flow rate - Zero cut flow rate12 L/min, 0.7 m3/h 24.72 ft3/h, 0.4 CFM
Flow rate - Measurement accuracy±(1.5% of RD + 0.5% of F.S.) *2 *3
Flow rate - Repeatability±1.0% of F.S. (with an averaging time of 1.0 s)
Flow rate - Display resolution1 L/min, 0.1 m3/h 3.53 ft3/h, 0.1 CFM
Flow rate - Response time150 ms (63% response) *4
Flow rate - Averaging timeOFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable)
Pressure (Digital value, gauge pressure) - Rated pressure range0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi
Pressure (Digital value, gauge pressure) - Measurement accuracy±2.0% of F.S.
Pressure (Digital value, gauge pressure) - Repeatability±0.2% of F.S. (with a response time of 50 ms)
Pressure (Digital value, gauge pressure) - Display resolution0.001 MPa, 0.01 bar, 0.1 psi
Pressure (Digital value, gauge pressure) - Response timeSelectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4
Humidity (Dew point) - Rated relative humidity range/ dew point range15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6
Humidity (Dew point) - Measurement accuracy±4°C, ±7°F *5 *6
Humidity (Dew point) - Display resolution5%RH/1°C, 1°F *5 *6
Temperature - Measurement accuracy±2.0°C, ±3.6°F *7
Temperature - Display resolution0.1°C, 0.1°F *7
Shut-off valve - Response time1 s or less (closed → open)
Shut-off valve - Leakage amount50 mL/min 0.002 CFM (N) or less
Filter/regulator (Standard model only) - Pressure adjustment range─
Check valveAvailable
DisplayColor LCD, status indicator
Data accumulation - Accumulation periodAccumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks
Data accumulation - Data readingUSB 2.0/Ethernet
I/O - Control output (Ch.1/2/3/4/5)NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less
I/O - Analog output (Ch.1/2)4 to 20 mA, load resistance: 260 Ω or less *4
I/O - External input (Ch.2/3/6)Short-circuit current: 1.5 mA or less, input time: 20 ms or more
Protection circuitPower supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output
Power supply - Power voltage24 VDC +25%/-20% (including ripple), Class 2 or LPS
Power supply - Power consumption1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current)
Communication interfaceUSB2.0
Network compatibilityWhen using only this unit: IO-Link (Specification v1.1/COM3) *9When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP
Environmental resistance - Enclosure ratingIP67 (IEC60529) *10
Environmental resistance - Ambient temperature−5°C to +50°C 23°F to 122°F (no freezing) *11
Environmental resistance - Relative humidity35%RH to 85%RH (no condensation)
Environmental resistance - Vibration resistance10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions
Environmental resistance - Shock resistance300 m/s2, XYZ axes, 10 times for each axis
MaterialSensor part : PET/PPS/PBT/POM/aluminum/SPHCFilter/regulator : Aluminum/POM/HDPE/NBR/Nylon *12
WeightApprox. 1920 g 67.73 oz

MP-FG80: frequently asked questions

When can MP-FG80 be shipped?

MP-FG80 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up MP-FG80 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for MP-FG80 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MP-FG80, subject to availability and destination.

More Keyence parts

Keyence MP-FG10RM – Spare filter regulator G3/8". . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FG10RM

Spare filter regulator G3/8".

Keyence MP-FG20 – Single model G1/2 (15 A). . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FG20

Single model G1/2 (15 A).

Keyence MP-FG20R – Standard model G1/2 (15 A). . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FG20R

Standard model G1/2 (15 A).

Keyence MP-FG20RM – Spare filter regulator G1/2". . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FG20RM

Spare filter regulator G1/2".

Keyence MP-FN10 – Single model NPT3/8 (10 A). . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FN10

Single model NPT3/8 (10 A).

Keyence MP-FN10R – Standard model NPT3/8 (10 A). . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FN10R

Standard model NPT3/8 (10 A).

Keyence MP-FN10RM – Spare filter regulator NPT3/8". . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FN10RM

Spare filter regulator NPT3/8".

Keyence MP-FN20 – Single model NPT1/2 (15 A). . Series: Air Quality Multi-Sensor. Series code: MP-F series
Keyence
MP-FN20

Single model NPT1/2 (15 A).

Keyence MP-FG80Price and lead time confirmed within 1 business day
Request a Quote