Keyence IX-1050

Sensor Amplifier Expansion unit. . Series: Image-Based Laser Sensor. Series code: IX series

MPN
IX-1050
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Keyence IX-1050?

Sensor Amplifier Expansion unit. IX-1050. Series: Image-Based Laser Sensor. Series code: IX series

Specifications

Specifications

Model NameSensor Amplifier Expansion unit
Model CodeIX-1050
Series TitleImage-Based Laser Sensor
Series CodeIX series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57336&dlModelId=PM_2631050&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/sensor/laser/ix/downloads/?mode=cd&modelId=PM_2631050
Manuals URLhttps://www.keyence.com/products/sensor/laser/ix/downloads/?mode=ma&modelId=PM_2631050
ModelIX-1050
Main unit / expansion unitExpansion unit
Display - Min. display unit10 µm*1
Display - Display range±999.99 to ±999 mm (with 4 selectable steps)*1
Tools - Scan modeHeight, Height difference, Max./Min., Height difference calculation, Thickness calculation, Height detection, Monochromatic detection, Position adjustment(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool*2
Tools - Line modeHeight (Ave./Max./Min.) , Height difference (Ave./Max./Min.) , Height difference calculation, Thickness calculation, Position adjustment, Tilt correction(Max. number of settings) Detection: 16 tools, Position adjustment: 1 tool, Alignment adjustment: 1 tool*2
Other functions - CommonZERO/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement,Zero/offset recording,Capture mode (HDR) Sensor date/time Information addition, N.O./N.C. switching, I/O monitor,Automatic brightness adjustment, Lighting (ON/OFF) , Total judgment conditions,NPN/PNP switching, Simultaneous main unit/expansion unit input, Light interference prevention, Security
Other functions - Scan modeMeasurement range, Measurement position (small/standard/large) , Measurement mode, Measurement noise elimination, Imaging mode (high gain) , Tilt correction (fixed or real-time correction) , Glare removal, Trigger input (internal/external) ,Trigger interval, Trigger delay, Trigger error, Monochrome histogram, Fixed reference area, Mask outline, Rotation range
Other functions - Line modeAverage count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, HOLD function, Alarm setting, Measurement method (Ave./Max./Min.)
Input - InputNon-voltage input/voltage input is switchableFor non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)For voltage input: Maximum input rating 26.4 V, ON voltage 18 V or higher, OFF current 0.2 mA or lower, ON current 2 mA (for 24 V)
Input - Number of inputs8 (IN1 to IN8)
Input - FunctionIN1: External trigger up/down timing, IN2 to IN8: Enable by assigning optional functionsAssignable functions: Program switching, Laser emission stop, Zero/offset (batch) , Reset (error only) , Reset (judgment value only) Reset (judgment value and error)
Output - OutputOpen collector output; NPN/PNP switchable, N.O./N.C. switchableFor open collector NPN output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 1.5 V or lessFor open collector PNP output: Maximum rating of 26.4 V, 50 mA (20 mA when linked to an expansion unit) , residual voltage of 2 V or less
Output - Number of inputs10 (OUT1 to OUT10)
Output - FunctionEnable by assigning the optional functionsAssignable functions: Total judgment result (All OK, Any OK/NG) , run, busy, error, position adjustment result, tilt correction result,Monochromatic detection/Height detection tool result (OK/NG) , Height/height difference/Max./Min./calculation tool result (OK/NG/HIGH/LO) , Alarm
Analog voltage outputNot available
Number of programs32
Statistical informationScan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)Line mode: Measured value / Degree of similarity (Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)*1*3
Detection record - Number of storage80 images (FTP/SFTP Client function: Enable)100 images (FTP/SFTP Client function: Disable) *4
Detection record400 images (FTP/SFTP Client function: Enable)500 images (FTP/SFTP Client function: Disable) *4
Detection historyNG only/All is selectable*4
FTP/SFTP data transfer (FTP/SFTP client function) - Transfer DestinationFTP/SFTP server
FTP/SFTP data transfer (FTP/SFTP client function) - Transfer formatbmp/jpeg/txt is selectable
FTP/SFTP data transfer (FTP/SFTP client function) - Transfer Condition4 conditionsAll / Total status result (OK/NG) / Result for each tool (OK/(NG and ALM)) is selectable
Ethernet - StandardNot available
Interface compatibilityCC-Link / DeviceNet® / EtherNet/IP™ / EtherCATⓇ / RS-232C / BCD / PROFINET / PROFIBUS / TCP/IP output*5
Number of connectible unitsMain units: 1, Expansion units: 1, Communication units (DL) : 1
Ratings - Power voltageSupplied from main unit
Ratings - Current consumptionMax. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load)*6
Environmental resistance - Ambient temperature0 to +50°C 32 to 122°F (No freezing)
Environmental resistance - Relative humidity35 to 85 % RH (No condensation)
MaterialMain unit case: PC/Power connector: PA, POM/Analog output connector: PA, POM/I/O connector: PA/Head connector: Zinc + Ni plating, PA/Ethernet connector: Copper alloy + Ni plating/Rear heat sink: Aluminum/Main unit rear DIN rail fixing tab: POM/Nameplate: PC
WeightApprox. 190 g

IX-1050: frequently asked questions

When can IX-1050 be shipped?

IX-1050 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up IX-1050 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for IX-1050 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IX-1050, subject to availability and destination.

More Keyence parts

Keyence IX-055 – Sensor Head 55 mm. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-055

Sensor Head 55 mm. . Series: Image-Based Laser Sensor.…

Keyence IX-080 – Sensor Head 80 mm. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-080

Sensor Head 80 mm. . Series: Image-Based Laser Sensor.…

Keyence IX-1000 – Sensor Amplifier Main unit. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-1000

Sensor Amplifier Main unit.

Keyence IX-150 – Sensor Head 150 mm. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-150

Sensor Head 150 mm. . Series: Image-Based Laser Sensor.…

Keyence IX-360 – Sensor Head 360 mm. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-360

Sensor Head 360 mm. . Series: Image-Based Laser Sensor.…

Keyence IX-360W – Sensor Head 360 mm. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-360W

Sensor Head 360 mm. . Series: Image-Based Laser Sensor.…

Keyence IX-CP50 – IX Series Control Panel. . Series: Image-Based Laser Sensor. Series code: IX series
Keyence
IX-CP50

IX Series Control Panel.

Keyence IX-1050Price and lead time confirmed within 1 business day
Request a Quote