Keyence FI-T8

Temperature Sensors 6A/8A. . Series: Clamp-On Flow Sensor. Series code: FD-H series

MPN
FI-T8
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Keyence FI-T8?

Temperature Sensors 6A/8A. FI-T8. Series: Clamp-On Flow Sensor. Series code: FD-H series

Specifications

Specifications

Model NameTemperature Sensors 6A/8A
Model CodeFI-T8
Series TitleClamp-On Flow Sensor
Series CodeFD-H series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157135&dlModelId=PM_273T8&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-h/downloads/?mode=cd&modelId=PM_273T8
Manuals URLhttps://www.keyence.com/products/process/flow/fd-h/downloads/?mode=ma&modelId=PM_273T8
ModelFI-T8
Supported pipe diameter1/8", 1/4"(6 A, 8 A)ø8–14 ø0.31"–0.55"
Supported pipe materialsMetal piping
Supported temperature range−20 to +180°C –4 to +356°F*1
Display methodOrganic EL, status indicator light
Display resolution0.1°C 32.18°F
Response time5 s (50% response), 15 s (90% response)*2
Display amplifier averaging time0.1 s / 10.0 s / 20.0 s / 30.0 s / 60.0 s / 120.0 s / 300.0 s
Measurement accuracy±0.5°C ±0.9°F (pipe temperature −20 to +80°C –4 to 176°F) (ambient temperature of 25°C 77°F)*2*3±1.0°C ±1.8°F (pipe temperature 80–180°C 176–356°F) (ambient temperature of 25°C 77°F)*2*3
HysteresisVariable
Measurement principlePt100 4-wire type
Power I/O connectorM8 4-pin connector
Power supply20 mA or less (excluding load current)*4
When used standalone - I/O (switchable)Control output: switching NPN/PNP settingOpen collector output: 30 VDC or less, maximum 100 mA/ch or less, residual voltage 2.5 V or less*5
When used standalone4–20 mA / 0–20 mA (switchable), load resistance 260 Ω or less*5
When used standalone - Power voltage20–30 VDC, ripple (P-P) 10% included; Class2/LPS*5
When used standalone - Protection circuitProtection against reverse power connection, power supply surges, output short circuits, and output surges*5
When used standalone - Network compatibilityIO-Link*6*5
Environmental resistance - Enclosure ratingIP65/IP67 (IEC60529)
Environmental resistance - Ambient temperature–10 to +60°C -14 to +140°F (no freezing)
Environmental resistance - Relative humidity35–85% RH (no condensation)
Environmental resistance - Vibration resistance10–500 Hz; power spectral density: 0.816 G2/Hz; X, Y and Z directions
Environmental resistance - Shock resistance100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions
Material - Display amplifierPBT / PAR / POM / SUS303
Material - Sensor headHead: PPS / SUS303 / Sn; Pipe clamp unit: SUS304; Cable: fluororesin
Material - Display amplifier mounting bracketSUS304
WeightApprox. 70 g 2.47 oz

FI-T8: frequently asked questions

When can FI-T8 be shipped?

FI-T8 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FI-T8 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FI-T8 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FI-T8, subject to availability and destination.

More Keyence parts

Keyence FI-T15 – Temperature Sensors 10A/15A. . Series: Clamp-On Flow Sensor. Series code: FD-H series
Keyence
FI-T15

Temperature Sensors 10A/15A.

Keyence FI-T200 – Temperature Sensors 125A/150A/200A. . Series: Clamp-On Flow Sensor. Series code: FD-H series
Keyence
FI-T200

Temperature Sensors 125A/150A/200A.

Keyence FI-T25 – Temperature Sensors 20A/25A. . Series: Clamp-On Flow Sensor. Series code: FD-H series
Keyence
FI-T25

Temperature Sensors 20A/25A.

Keyence FI-T50 – Temperature Sensors 32A/40A/50A. . Series: Clamp-On Flow Sensor. Series code: FD-H series
Keyence
FI-T50

Temperature Sensors 32A/40A/50A.

Keyence FL-001 – Amplifier Unit, Standard Specification. . Series: Sensing Guide Pulse Level Sensor. Series code: FL series
Keyence
FL-001

Amplifier Unit, Standard Specification.

Keyence FL-C001 – Amplifier Unit, Resin Specification. . Series: Sensing Guide Pulse Level Sensor. Series code: FL series
Keyence
FL-C001

Amplifier Unit, Resin Specification.

Keyence FL-CP100 – Probe, Resin Specification 1000 mm. . Series: Sensing Guide Pulse Level Sensor. Series code: FL series
Keyence
FL-CP100

Probe, Resin Specification 1000 mm.

Keyence FL-CP120 – Probe, Resin Specification 1200 mm. . Series: Sensing Guide Pulse Level Sensor. Series code: FL series
Keyence
FL-CP120

Probe, Resin Specification 1200 mm.

Keyence FI-T8Price and lead time confirmed within 1 business day
Request a Quote