Quick facts

AvailabilityConfirmed on request
CategoryClamp-On Gas Flow Meter
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)
Weight2.7 kg

Shipping & availability

When can FD-G50L be shipped?

FD-G50L is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FD-G50L in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FD-G50L and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FD-G50L, subject to availability and destination.

Clamp-On Gas Flow Meter DN 32A/40A/50A. FD-G50L. Series: Clamp-On Gas Flow Meter. Series code: FD-G series

Specifications

Specifications

Model NameClamp-On Gas Flow Meter DN 32A/40A/50A
Model CodeFD-G50L
Series TitleClamp-On Gas Flow Meter
Series CodeFD-G series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_SR57345&dlModelId=PM_160G50L&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-g/downloads/?mode=cd&modelId=PM_160G50L
Manuals URLhttps://www.keyence.com/products/process/flow/fd-g/downloads/?mode=ma&modelId=PM_160G50L
ModelFD-G50L
Pipe size - DN (Diameter Nominal)32 A, 40 A, 50 A
Pipe size - NPS (Nominal Pipe Size)1 1/4", 1 1/2", 2"
Pipe size - Outer diameter of pipeø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44"
Pipe size - Pipe thickness1.65 to 3.5 mm 0.06" to 0.138"
Supported pipe materialsIron, steel, stainless steel
Supported fluidsAir, Nitrogen, other gases*1
Fluid temperature0 to 60ºC 32 to 140 °F
Recommended pressure0.4 MPa or greater (58 PSI or greater)
Rated velocity of flow rangeUp to 15 m/s
Actual flow rate range (typical) - m3/hPipe size 32 A: 54.00Pipe size 40 A: 72.00Pipe size 50 A: 120.00
Actual flow rate range (typical) - L/minPipe size 32 A: 900.0Pipe size 40 A: 1200.0Pipe size 50 A: 2000.0
Actual flow rate range (typical) - CFMPipe size 32 A: 32.00Pipe size 40 A: 42.00Pipe size 50 A: 70.00
Standard flow rate range (typical) [CFM] - 20°C 68°F 60 psi 0.41 MPaPipe size 32 A: 151.58Pipe size 40 A: 198.95Pipe size 50 A: 331.58
Standard flow rate range (typical) [CFM] - 20°C 68°F 80 psi 0.55 MPaPipe size 32 A: 192.17Pipe size 40 A: 252.22Pipe size 50 A: 420.37
Standard flow rate range (typical) [CFM] - 20°C 68°F 100 psi 0.69 MPaPipe size 32 A: 232.76Pipe size 40 A: 305.49Pipe size 50 A: 509.16
Standard flow rate range (typical) [CFM] - 20°C 68°F 120 psi 0.83 MPaPipe size 32 A: 273.35Pipe size 40 A: 358.77Pipe size 50 A: 597.95
DisplayQVGA 2.2" LCD color monitor
Display update cycleApprox. 3 Hz
Display resolution - Instantaneous flow rate0.01 m3/h, 0.1 L/min, 0.01 CFM
Display resolution - Consumption/leakage amount0.01 m3, 1 L, 0.1 CF
Response time1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)
Measurement accuracy - Between 10 and 100% of F.S.±2.0% of RD*2*3*4*5
Measurement accuracy - Between 1 and 10% of F.S.±1.0% of F.S.*2*3*4*5
Zero point error±0.15% of F.S.*2*6
Static leakage repeatability±1.0% of RD*4*7
HysteresisVariable
Flow unitsCFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min
I/O wiring connection portM12 4-pin connector (male)
Detection mode (switchable) - ch.1Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8
Detection mode (switchable) - ch.2Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8
Standard I/O (switchable) - Control output (ch.1/ch.2)NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less
Standard I/O (switchable) - Analog output (ch.2)4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less
Standard I/O (switchable) - External input (ch.2)Short-circuit current: 1.5 mA or less, input time: 20 ms or more
Protection circuitPower supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output
Analog input (for volume conversion)M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less
Power supplied to pressure sensorSupply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)
Communication interface - USBUSB 2.0
Communication interface - EthernetIEEE 802.3u (100BASE-TX)
Communication interface100 Mbps
Network functionModbus TCP, EtherNet/IP™, IO-Link*9
Recording capacity - Consumption amount/ leakage amountApprox. 5 years
Recording capacity - Events100
Power supply - Power voltage20 to 30 VDC including 10% ripple (P-P), Class 2
Power supply - Power consumption350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)
Environmental resistance - Enclosure ratingIP65/67 (IEC 60529)*10
Environmental resistance - Ambient temperatureDetection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)
Environmental resistance - Relative humidity5 to 85%RH (no condensation)
Environmental resistance - Vibration resistance10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes
Environmental resistance - Shock resistance100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis
Material - Display unitBody: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating
Material - Detection headBody: PPS/SUS304, rear surface: rubber
Material - Mounting/damping bracketSUS304
WeightApprox. 2.7 kg
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Keyence parts

Keyence LR-ZH490CB UsedUsedKeyence LR-ZH490CB Used
MPN: LR-ZH490CB · Keyence
€200.34
View details
Keyence RK-10IYCAvailable on requestKeyence RK-10IYC
MPN: RK-10IYC · Keyence
Price on request
Request a quote
Keyence RK-10IYAvailable on requestKeyence RK-10IY
MPN: RK-10IY · Keyence
Price on request
Request a quote
Keyence RK-10IMCAvailable on requestKeyence RK-10IMC
MPN: RK-10IMC · Keyence
Price on request
Request a quote