Keyence FD-EPH9

Sensor head Outer diameter of pipe 3/8”.

MPN
FD-EPH9
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Keyence FD-EPH9?

Sensor head Outer diameter of pipe 3/8”. FD-EPH9. Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series

Specifications

Specifications

Model NameSensor head Outer diameter of pipe 3/8”
Model CodeFD-EPH9
Series TitleAir Flow and Pressure Dual Sensor
Series CodeFD-EP series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157152&dlModelId=PM_160EPH9&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-ep/downloads/?mode=cd&modelId=PM_160EPH9
Manuals URLhttps://www.keyence.com/products/process/flow/fd-ep/downloads/?mode=ma&modelId=PM_160EPH9
ModelFD-EPH9
Pipe size - Outer diameter of pipe3/8” (Approx.9.53 mm 0.38") *1
Pipe size - Compatible outer diameter range9.53 ±0.15 mm0.38" ±0.006"
Pipe size9.53 ±0.1 mm0.38" ±0.004"
Pipe size - Pipe materialsResin pipe connectible to a one-touch coupling
Supported gasesAir, nitrogen, argon, and non-corrosive gases*2
Supported gas temperature−10°C to +60°C 14 to 140°F
Pressure resistance1 MPa
Flow rate detection principleUltrasonic transmission time difference method
Flow rate specifications - Rated flow rate150 L/min 5.30 CFM
Flow rate specifications450 L/min 15.9 CFM
Flow rate specifications - Measurement accuracy±(2.0% of RD+1.0% of F.S.)*3*4
Flow rate specifications - RepeatabilityResponse time of 250 ms: ±2.5% of F.S.*3*5
Pressure specifications - Rated pressure−100 kPa to +0.75 MPa * However, the flow rate cannot be measured in the range of −100 to −30 kPa.
Pressure specifications - Overall accuracy±2.0% of F.S.*3
Pressure specifications - RepeatabilityResponse time of 2.5 ms: ±0.4% of F.S.
Display resolution - Instantaneous flow0.1/1 L/min
Display resolution - Accumulated flow0.1/1/10/100/1000 L
Display resolution - Pressure0.1/1 kPa
Environmental resistance - Enclosure ratingIP65 (IEC60529)
Environmental resistance - Ambient temperature−10°C to +60°C 14 to 140°F (no freezing)
Environmental resistance - Relative humidity35%RH to 85%RH (no condensation)
Environmental resistance - Vibration resistance10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes
Environmental resistance - Shock resistance100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis
Material - Sensor unit (parts that do not contact the gas)PBT/PAR/iron/Brass electroless nickel plating/POM/NBR/stainless steel
Material - Flow channel (parts that contact the gas)PBT/Brass electroless nickel plating/NBR/nylon
WeightApprox. 193 g 6.81 oz

FD-EPH9: frequently asked questions

When can FD-EPH9 be shipped?

FD-EPH9 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FD-EPH9 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FD-EPH9 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FD-EPH9, subject to availability and destination.

More Keyence parts

Keyence FD-EPH5 – Sensor head Outer diameter of pipe 3/16”.
Keyence
FD-EPH5

Sensor head Outer diameter of pipe 3/16”.

Keyence FD-EPH6 – Sensor head Outer diameter of pipe ø6. . Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series
Keyence
FD-EPH6

Sensor head Outer diameter of pipe ø6.

Keyence FD-EPH7 – Sensor head Outer diameter of pipe 1/4”.
Keyence
FD-EPH7

Sensor head Outer diameter of pipe 1/4”.

Keyence FD-EPH8 – Sensor head Outer diameter of pipe ø8. . Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series
Keyence
FD-EPH8

Sensor head Outer diameter of pipe ø8.

Keyence FD-G125 – Clamp-On Gas Flow Meter DN 100A/125A. . Series: Clamp-On Gas Flow Meter. Series code: FD-G series
Keyence
FD-G125

Clamp-On Gas Flow Meter DN 100A/125A.

Keyence FD-G125L – Clamp-On Gas Flow Meter DN 100A/125A. . Series: Clamp-On Gas Flow Meter. Series code: FD-G series
Keyence
FD-G125L

Clamp-On Gas Flow Meter DN 100A/125A.

Keyence FD-G200 – Clamp-On Gas Flow Meter DN 150A/200A. . Series: Clamp-On Gas Flow Meter. Series code: FD-G series
Keyence
FD-G200

Clamp-On Gas Flow Meter DN 150A/200A.

Keyence FD-G200L – Clamp-On Gas Flow Meter DN 150A/200A. . Series: Clamp-On Gas Flow Meter. Series code: FD-G series
Keyence
FD-G200L

Clamp-On Gas Flow Meter DN 150A/200A.

Keyence FD-EPH9Price and lead time confirmed within 1 business day
Request a Quote