Keyence FD-EPA1C

Amplifier Units M12 connector type. . Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series

MPN
FD-EPA1C
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the Keyence FD-EPA1C?

Amplifier Units M12 connector type. FD-EPA1C. Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series

Specifications

Specifications

Model NameAmplifier Units M12 connector type
Model CodeFD-EPA1C
Series TitleAir Flow and Pressure Dual Sensor
Series CodeFD-EP series
Data Sheet URLhttps://www.keyence.com/download/download/confirmation/?dlSeriesId=WS_157152&dlModelId=PM_16EPA1C&dlSiteId=1&dlLanguageId=en-US&dlLangType=en-US
CAD URLhttps://www.keyence.com/products/process/flow/fd-ep/downloads/?mode=cd&modelId=PM_16EPA1C
Manuals URLhttps://www.keyence.com/products/process/flow/fd-ep/downloads/?mode=ma&modelId=PM_16EPA1C
ModelFD-EPA1C
TypeM12 connector type*1
Number of control outputs3
Number of analog outputs1
Number of external inputs2
Power supply cablePigtail, 100 mm 3.94", M12 connector, 8 pins
Response time (90% response) - Flow rate50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 250 ms) *2
Response time (90% response) - Pressure2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, initial value: 2.5 ms) *2
I/O - Control outputs 1, 2, and 3Instantaneous flow/Accumulated flow/Pressure/Alarm output/Predictive maintenance output/Seating Confirmation (output 1 only)/Pulse output NPN/PNP setting switchable, 100 mA or less total for three outputs, residual voltage: 2.5 V or less
I/O - Analog outputInstantaneous flow/Pressure 4-20 mA/0-20 mA (switchable), load resistance: 260 Ω or less
I/O - External inputs 1 and 2Zero flow/Origin adjust./Atmospheric pressure correction/Pressure zero shift/Reset total/App. learning/App. reset Short-circuit current: 1.5 mA or less
Network compatibilityIO-Link*3
Number of connectible units─
Protection circuitProtection against reverse power connection, output overcurrent, output surge, reverse output connection, and incorrect head cable wiring
Power supply - Power voltage24 VDC + 20%/− 10% (including ripple), Class2/LPS
Power supply - Power consumption1870 mW excluding load current *4*5
Environmental resistance - Ambient temperature−10°C to +55°C 14 to 131°F (no freezing)*5
Environmental resistance - Relative humidity35%RH to 85%RH (no condensation)
Environmental resistance - Vibration resistance10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes
Environmental resistance - Shock resistance100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis
MaterialMain unit: polycarbonate, FG terminal: copper/iron
WeightApprox. 42 g 1.48 oz

FD-EPA1C: frequently asked questions

When can FD-EPA1C be shipped?

FD-EPA1C is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up FD-EPA1C in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for FD-EPA1C and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FD-EPA1C, subject to availability and destination.

More Keyence parts

Keyence FD-ECH8 – Sensor head ø8. . Series: Clamp-On Air Flow Sensor. Series code: FD-EC series
Keyence
FD-ECH8

Sensor head ø8. . Series: Clamp-On Air Flow Sensor. Series…

Keyence FD-ECH9 – Sensor head 3/8". . Series: Clamp-On Air Flow Sensor. Series code: FD-EC series
Keyence
FD-ECH9

Sensor head 3/8". . Series: Clamp-On Air Flow Sensor.…

Keyence FD-EPA0 – Amplifier Units Zero line type. . Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series
Keyence
FD-EPA0

Amplifier Units Zero line type.

Keyence FD-EPA1 – Amplifier Units Cable type. . Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series
Keyence
FD-EPA1

Amplifier Units Cable type.

Keyence FD-EPB1 – Mounting bracket (For sensor heads compatible with ø4 to 1/4”).
Keyence
FD-EPB1

Mounting bracket

Keyence FD-EPB2 – Mounting bracket (For sensor heads compatible with ø8).
Keyence
FD-EPB2

Mounting bracket (For sensor heads compatible with ø8).

Keyence FD-EPB3 – Mounting bracket (For sensor heads compatible with 3/8” to 1/2”).
Keyence
FD-EPB3

Mounting bracket

Keyence FD-EPH10 – Sensor head Outer diameter of pipe ø10. . Series: Air Flow and Pressure Dual Sensor. Series code: FD-EP series
Keyence
FD-EPH10

Sensor head Outer diameter of pipe ø10.

Keyence FD-EPA1CPrice and lead time confirmed within 1 business day
Request a Quote