What is the IFM SM6604?

Precise measurement of flow, consumption and medium temperature

High accuracy, repeatability and measurement dynamics

For use in water cooling circuits

With two precise analogue outputs

Clearly visible 4-digit LED display

Specifications

Product characteristics

Number of inputs and outputsNumber of analogue outputs: 2
Measuring range0.1...25 l/min; 0.03...6.6 gpm
0.1...25 l/min0.03...6.6 gpm
Process connectionthreaded connection 1/2" NPT internal thread DN15

Application

Special featureGold-plated contacts
Applicationfor industrial applications
Mediaconductive liquids; water; hydrous media
Note on mediaconductivity: ≥ 20 µS/cm; viscosity: < 70 mm²/s (40 °C)
Medium temperature[°C] [°C]-10...70
Pressure rating16 bar; 1.6 MPa
16 bar1.6 MPa
MAWP for applications according to CRN15.3 bar; 1.53 MPa
15.3 bar1.53 MPa

Electrical data

Operating voltage[V] [V]20...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]120; (24 V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]5
Measuring principlemagnetic-inductive

Inputs / outputs

Number of inputs and outputsNumber of analogue outputs: 2

Outputs

Total number of outputs2
Output signalanalogue signal
Number of analogue outputs2
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Overload protectionyes

Measuring/setting range

Measuring range0.1...25 l/min; 0.03...6.6 gpm
0.1...25 l/min0.03...6.6 gpm
Display range-30...30 l/min; -7.92...7.92 gpm
-30...30 l/min-7.92...7.92 gpm
Resolution0.05 l/min; 0.01 gpm
0.05 l/min0.01 gpm
Analogue start point ASP0...20 l/min; 0...5.28 gpm
0...20 l/min0...5.28 gpm
Analogue end point AEP5...25 l/min; 1.32...6.6 gpm
5...25 l/min1.32...6.6 gpm
In steps of0.02 l/min; 0.01 gpm
0.02 l/min0.01 gpm
Measuring range[°C] [°C]-20...80
Resolution[°C] [°C]0.2
Analogue start point[°C] [°C]-20...60
Analogue end point[°C] [°C]0...80
In steps of[°C] [°C]0.2

Accuracy / deviations

Accuracy (in the measuring range)± (2 % MW + 0,5 % MEW)
Repeatability± 0,2% MEW
Accuracy[K] [K]± 2,5 (Q > 1 l/min)

Response times

Response time[s] [s]0.15; (dAP = 0, T19)
Damping process value dAP[s] [s]0...3
Dynamic response T05 / T09[s] [s]T09 = 20 (Q > 1 l/min)

Operating conditions

Ambient temperature[°C] [°C]-10...60
Storage temperature[°C] [°C]-25...80
ProtectionIP 67

Tests / approvals

EMCDIN EN 60947-5-9; 500 V withstand voltage (V DC)
DIN EN 60947-5-9500 V withstand voltage (V DC)
CPA approvalmodel number; 008MI; accuracy class; -; maximum allowable error; ± 2,5 % FS; Q (min); 0,005 m³/h; Q (t); -; Q (max); 1,5 m³/h
model number008MI
accuracy class-
maximum allowable error± 2,5 % FS
Q (min)0,005 m³/h
Q (t)-
Q (max)1,5 m³/h
Shock resistanceDIN EN 60068-2-27; 20 g (11 ms)
DIN EN 60068-2-2720 g (11 ms)
Vibration resistanceDIN EN 68000-2-6; 5 g (10...2000 Hz)
DIN EN 68000-2-65 g (10...2000 Hz)
MTTF[years] [years]175
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]523.15
Housingcylindrical
Inlet pipe length3 x DN
Outlet pipe length1 x DN
Dimensions[mm] [mm]Ø 54 / L = 110
Materialsstainless steel (316L/1.4404); PBT-GF20; PC; FKM; TPE
Materials (wetted parts)stainless steel (316L/1.4404); PEEK; FKM
Process connectionthreaded connection 1/2" NPT internal thread DN15

Displays / operating elements

DisplayDisplay unit; 6 x LED, green (l/min, m³/h, gpm, gph, °C, °F); measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit
Display unitl/min; m³/h; gpm; gph; °C; °F
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

SM6604: frequently asked questions

When can SM6604 be shipped?

SM6604 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SM6604 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SM6604 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SM6604, subject to availability and destination.

More IFM parts

IFM SM6604Price and lead time confirmed within 1 business day
Request a Quote