IFM SD8600

MPN
SD8600
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the IFM SD8600?

Precise measurement of flow, consumption, pressure and medium temperature

High accuracy, repeatability and measurement dynamics

For detecting argon (Ar), carbon dioxide (CO2), nitrogen (N2) and compressed air

Red/green display for clear identification of the acceptable range

Display can be rotated for optimum alignment

Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range14...3750 l/min; 0.4...103.7 m/s; 0.8...225 m³/h
14...3750 l/min0.4...103.7 m/s
Process connectionthreaded connection R 1 external thread DN25

Application

Applicationfor industrial applications
MediaArgon (Ar); carbon dioxide (CO2); nitrogen (N2); compressed air
Medium temperature[°C] [°C]-10...60
Min. burst pressure64 bar; 6.4 MPa
64 bar6.4 MPa
Pressure rating16 bar; 1.6 MPa
16 bar1.6 MPa
MAWP for applications according to CRN[bar] [bar]10.5

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 80
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Inputs

Inputscounter reset

Outputs

Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]150; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-10...60 °C; 14...140 °F
14...3750 l/min0.4...103.7 m/s
Display range-24...74 °C; -11.2...165.2 °F
0...4500 l/min0...124.4 m/s
Resolution0.2 °C; 0.5 °F
2 l/min0.1 m/s
Set point SP-9.7...60 °C; 14.6...140 °F
32...3749 l/min0.9...103.7 m/s
Reset point rP-10...59.7 °C; 14...139.4 °F
14...3730 l/min0.4...103.2 m/s
Analogue start point ASP0...3000 l/min; 0...83 m/s; 0...180 m³/h
0...3000 l/min0...83 m/s
Analogue end point AEP750...3750 l/min; 20.7...103.7 m/s; 45...225 m³/h
750...3750 l/min20.7...103.7 m/s
Low flow cut-off LFC4...40 l/min; 0.1...1.1 m/s; 0.3...2.4 m³/h
4...40 l/min0.1...1.1 m/s
In steps of0.1 °C; 0.1 °F
1 l/min0.1 m/s
Measuring range[bar] [bar]-1...16
Display range[bar] [bar]-1...20
Resolution[bar] [bar]0.05
Set point SP[bar] [bar]-0.92...16
Reset point rP[bar] [bar]-1...15.92
Analogue start point[bar] [bar]-1...12.8
Analogue end point[bar] [bar]2.2...16
In steps of[bar] [bar]0.01
0...100000000 m³0...353146667.2 scf
0.001...10000000 m³0.05...353146667.2 scf
Pulse value0.001...10000000 m³; 0.05...353146667.2 scf
0.0001 m³0.005 scf
Pulse length[s] [s]0.007...2
-10...60 °C14...140 °F
-24...74 °C-11.2...165.2 °F
0.2 °C0.5 °F
-9.7...60 °C14.6...140 °F
-10...59.7 °C14...139.4 °F
Analogue start point-10...46 °C; 14...114.8 °F
-10...46 °C14...114.8 °F
Analogue end point4...60 °C; 39.2...140 °F
4...60 °C39.2...140 °F
0.1 °C0.1 °F

Accuracy / deviations

Temperature coefficient[1/K] [1/K]± 0,07 % MW
Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); at medium temperature 23 °C
Repeatability± (0,4 % MW + 0,1 % MEW)
Repeatability[% of the final value] [% of the final value]± 0,2
Characteristics deviation[% of the final value] [% of the final value]< ± 0,5; (BFSL = Best Fit Straight Line)
Greatest TEMPCO of the span[% MEW / 10 K] [% MEW / 10 K]± 0,3
Greatest TEMPCO of the zero point[% MEW / 10 K] [% MEW / 10 K]± 0,1
Accuracy[K] [K]± 0,5; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.05
Damping process value dAP[s] [s]0...5
Dynamic response T05 / T09[s] [s]T09 = 0,5

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 CDV
ProfilesCommon - I&D; Identification and Diagnosis; Function; Measurement data, standard resolution
Common - I&DIdentification and Diagnosis
FunctionMeasurement data, standard resolution
SIO modeyes
Required master port typeA
Process data analogue8
Process data binary2
Min. process cycle time[ms] [ms]7.2
Supported DeviceIDsdefault; 868
default868

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90
ProtectionIP 65; IP 67

Tests / approvals

EMCDIN EN 60947-5-9
CPA approvalmodel number; 003TG; accuracy class; -; maximum allowable error; ± 7 % FS; Q (min); 0,8 m³/h; Q (t); -; Q (max); 225 m³/h
model number003TG
accuracy class-
maximum allowable error± 7 % FS
Q (min)0,8 m³/h
Q (t)-
Q (max)225 m³/h
Vibration resistanceDIN EN 68000-2-6; 5 g (10...2000 Hz)
DIN EN 68000-2-65 g (10...2000 Hz)
MTTF[years] [years]183
UL approvalUL approval no.; I012; File number UL; E174189
UL approval no.I012
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for stable gases fluid group 2

Mechanical data

Weight[g] [g]1530
Housingrectangular
Dimensions[mm] [mm]475 x 45.4 x 83.1
MaterialsPBT+PC-GF30; PPS GF40; stainless steel (304/1.4301); stainless steel (303/1.4305); steel (1.5523) galvanised; 2.0401 (brass / CW614N); FKM
Materials (wetted parts)stainless steel (304/1.4301); stainless steel (303/1.4305); FKM; ceramics glass passivated; PPS GF40; Al2O3 (ceramics); acrylate
Process connectionthreaded connection R 1 external thread DN25

Displays / operating elements

Displaycolour display 1,44", 128 x 128 pixels; 2 x LED, yellow

Remarks

RemarksMW = measured value; MEW = Final value of the measuring range; Standard conditions: 1013.25 mbar / 15 °C / 0 % relative humidity; For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

SD8600: frequently asked questions

When can SD8600 be shipped?

SD8600 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SD8600 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SD8600 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD8600, subject to availability and destination.

More IFM parts

IFM SD8600Price and lead time confirmed within 1 business day
Request a Quote