What is the IFM SD2001?

Precise measurement of flow, consumption and medium temperature

High accuracy, repeatability and measurement dynamics

For detecting compressed air in industrial use

With switching output, analogue output and pulse output

Clearly visible 4-digit LED display

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range90...24720 scfh; 1.4...412 scfm
90...24720 scfh1.4...412 scfm
Process connectionthreaded connection 2" NPT external thread DN50

Application

Applicationfor industrial applications
Mediacompressed air
Note on mediaair quality ISO 8573-1; class 141; class 344
Medium temperature[°F] [°F]32...140
Pressure rating16 bar; 232 psi; 1.6 MPa
16 bar232 psi
MAWP for applications according to CRN[bar] [bar]16

Electrical data

Operating voltage[V] [V]19...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]0.5

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range90...24720 scfh; 1.4...412 scfm
90...24720 scfh1.4...412 scfm
Display range0...29670 scfh; 0...494.4 scfm
0...29670 scfh0...494.4 scfm
Set point SP220...24720 scfh; 3.7...412 scfm
220...24720 scfh3.7...412 scfm
Reset point rP100...24600 scfh; 1.6...409.9 scfm
100...24600 scfh1.6...409.9 scfm
Analogue start point ASP0...18540 scfh; 0...309 scfm
0...18540 scfh0...309 scfm
Analogue end point AEP6180...24720 scfh; 103...412 scfm
6180...24720 scfh103...412 scfm
In steps of0.020...1000 scf
10 scfh0.1 scfm
Pulse value0.400...4 000 000 scf
Pulse length[s] [s]0,049... 2
Measuring range[°F] [°F]32...140
Display range[°F] [°F]32...140

Accuracy / deviations

Repeatability[% of the measured value] [% of the measured value]± 1,5
Accuracy (in the measuring range)± (3 % MW + 0,3 % MEW) / ± (6 % MW + 0,6 % MEW); (class 141 /; class 344; conditions: installation to DIN ISO 2533; installation in pipes: DN50)
Accuracy[K] [K]± 2; (medium flow in the limit area of the flow measurement range)

Response times

Response time[s] [s]0.1; (dAP = 0)
Damping process value dAP in steps[s] [s]0 - 0,2 - 0,4 - 0,6 - 0,8 - 1

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit

Operating conditions

Ambient temperature[°F] [°F]32...140
Storage temperature[°F] [°F]-4...185
Max. relative air humidity[%] [%]90
ProtectionIP 65

Tests / approvals

EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Vibration resistanceDIN EN 68000-2-6; 5 g (55...2000 Hz)
DIN EN 68000-2-65 g (55...2000 Hz)
MTTF[years] [years]227
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]4269.5
Housingrectangular
Dimensions[mm] [mm]475 x 100 x 133
MaterialsPBT-GF20; NBR; PC; stainless steel (304/1.4301); PTFE; brass coated; FKM; aluminium powder-coated
Materials (wetted parts)stainless steel (304/1.4301); FKM; ceramics glass passivated; PEEK GF30; polyester; aluminium
Process connectionthreaded connection 2" NPT external thread DN50

Displays / operating elements

DisplayDisplay unit; 4 x LED, green (scfm, scfh, scf, °F); function display; 1 x LED, yellow; switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit
Display unit4 x LED, green (scfm, scfh, scf, °F)
function display1 x LED, yellow
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

Remarksscf = standard cubic feet; scfh = standard cubic feet per hour; scfm = standard cubic feet per minute; MW = measured value; MEW = Final value of the measuring range; Measuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; For information about installation and operation please see the operating instructions.
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

SD2001: frequently asked questions

When can SD2001 be shipped?

SD2001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SD2001 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SD2001 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD2001, subject to availability and destination.

More IFM parts

IFM SD2001Price and lead time confirmed within 1 business day
Request a Quote