IFM SD0523

MPN
SD0523
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the IFM SD0523?

Precise measurement of flow, consumption and medium temperature

High accuracy, repeatability and measurement dynamics

For detecting compressed air in industrial use

With switching output, analogue output and pulse output

Adjustable to inside pipe diameters

Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1
Measuring range0.5...143.9 m/s; 8...2110 m³/h; 0.12...35.18 m³/min
0.5...143.9 m/s8...2110 m³/h
Process connectionthreaded connection G 1 internal thread

Application

InstallationAdjustable to inside pipe diameters; (38...254 mm)
Mediacompressed air
Medium temperature[°C] [°C]0...60
Pressure rating16 bar; 232 psi; 1.6 MPa
16 bar232 psi
MAWP for applications according to CRN[bar] [bar]16

Electrical data

Operating voltage[V] [V]18...30 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 110
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]1

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; pulse signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]250; (per output)
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (scalable)
Max. load[Ω] [Ω]500
Pulse outputconsumed quantity meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range0.5...143.9 m/s; 8...2110 m³/h; 0.12...35.18 m³/min
0.5...143.9 m/s8...2110 m³/h
Display range0...172.7 m/s; 0...2532 m³/h; 0...42.22 m³/min
0...172.7 m/s0...2532 m³/h
Resolution0.1 m/s; 2 m³/h; 0.02 m³/min
0.1 m/s2 m³/h
Set point SP1.2...143.9 m/s; 18...2110 m³/h; 0.28...35.18 m³/min
1.2...143.9 m/s18...2110 m³/h
Reset point rP0.5...143.2 m/s; 6...2100 m³/h; 0.12...35 m³/min
0.5...143.2 m/s6...2100 m³/h
Analogue start point ASP0...107.9 m/s; 0...1582 m³/h; 0...26.38 m³/min
0...107.9 m/s0...1582 m³/h
Analogue end point AEP36...143.9 m/s; 528...2110 m³/h; 8.8...35.18 m³/min
36...143.9 m/s528...2110 m³/h
In steps of1 Nm³
Pulse value1...1000 x 10³
Pulse length[s] [s]0,7...2 (D = 72 mm)
Measuring range[°C] [°C]0...60
Display range[°C] [°C]-12...72
Resolution[°C] [°C]0.2
Set point SP[°C] [°C]0.4...60
Reset point rP[°C] [°C]0.2...59.8
Analogue start point[°C] [°C]0...45
Analogue end point[°C] [°C]15...60
In steps of[°C] [°C]0.2

Accuracy / deviations

Repeatability[% of the measured value] [% of the measured value]± 1,5
Accuracy (in the measuring range)± (6 % MW + 0,6 % MEW); (D = 72mm, T = 22 °C; standard volume flow: 50...850 Nm³/h)
Accuracy[K] [K]± 2,5 (Q > 2 Nm³/h)

Response times

Response time[s] [s]0.1; (dAP = 0)
Damping process value dAP in steps[s] [s]0 - 0,2 - 0,4 - 0,6 - 0,8 - 1
Dynamic response T05 / T09[s] [s]30 (Q > 2 Nm³/h)

Software / programming

Parameter setting optionsFlow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; current/pulse output; display can be rotated and switched off; Display unit; totaliser

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
SIO modeyes
Required master port typeA
Process data analogue3
Process data binary2
Min. process cycle time[ms] [ms]4.1
Supported DeviceIDsdefault; 381
default381

Operating conditions

Ambient temperature[°C] [°C]0...60
Storage temperature[°C] [°C]-20...85
Max. relative air humidity[%] [%]90
ProtectionIP 65

Tests / approvals

EMCDIN EN 60947-5-9; DIN EN 61000-6-3
Vibration resistanceDIN EN 60068-2-6; 5 g (55...2000 Hz)
DIN EN 60068-2-65 g (55...2000 Hz)
MTTF[years] [years]213

Mechanical data

Weight[g] [g]539.5
Housingrectangular
Dimensions[mm] [mm]114.1 x 45 x 98.2
MaterialsPBT-GF20; PC; stainless steel (304/1.4301); FKM
Materials (wetted parts)stainless steel (316 / 1.4401); stainless steel (304/1.4301); ceramics glass passivated; PEEK; polyester; FKM
Process connectionthreaded connection G 1 internal thread
Probe diameter[mm] [mm]12
Installation length EL[mm] [mm]35.5

Displays / operating elements

DisplayDisplay unit; 4 x LED, green (Nm³/min, Nm³/h, Nm³, °C); function display; 1 x LED, green; switching status; 2 x LED, yellow; measured values; alphanumeric display, 4-digit; programming; alphanumeric display, 4-digit
Display unit4 x LED, green (Nm³/min, Nm³/h, Nm³, °C)
function display1 x LED, green
switching status2 x LED, yellow
measured valuesalphanumeric display, 4-digit
programmingalphanumeric display, 4-digit

Remarks

RemarksMeasuring, display and setting ranges refer to the standard volume flow according to DIN ISO 2533.; D = inside pipe diameter
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

SD0523: frequently asked questions

When can SD0523 be shipped?

SD0523 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SD0523 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SD0523 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SD0523, subject to availability and destination.

More IFM parts

IFM SD0523Price and lead time confirmed within 1 business day
Request a Quote