What is the IFM PX9524?

Precise linear 0...10 V output signal

High repeatability and low linearity error

With long-term stability thanks to high overload protection

Robust stainless steel housing for use in harsh industrial environments

Wide operating temperature range

Specifications

Product characteristics

Number of inputs and outputsNumber of analogue outputs: 1
Measuring range0...10 bar; 0...145 psi; 0...100 kPa
0...10 bar0...145 psi
Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2)

Application

Special featureGold-plated contacts
Measuring elementceramic-capacitive pressure measuring cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-25...90; (on request: -40...90 °C)
Min. burst pressure150 bar; 2175 psi; 15000 kPa
150 bar2175 psi
Pressure rating75 bar; 1087 psi; 7500 kPa
75 bar1087 psi
Vacuum resistance[mbar] [mbar]-1000
Type of pressurerelative pressure

Electrical data

Operating voltage[V] [V]16...32 DC; (depends on the lubrication, the seal and the pressure load)
Current consumption[mA] [mA]< 18
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes

Inputs / outputs

Number of inputs and outputsNumber of analogue outputs: 1

Outputs

Total number of outputs1
Output signalanalogue signal
Number of analogue outputs1
Analogue voltage output[V] [V]0...10
Min. load resistance[Ω] [Ω]2000
Overload protectionyes

Measuring/setting range

Measuring range0...10 bar; 0...145 psi; 0...100 kPa
0...10 bar0...145 psi

Accuracy / deviations

Repeatability[% of the span] [% of the span]< 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,45; (0...80 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,2; (0...80 °C)

Response times

Step response time analogue output[ms] [ms]3

Operating conditions

Ambient temperature[°C] [°C]-25...80
Storage temperature[°C] [°C]-40...100
ProtectionIP 68; IP 69K

Tests / approvals

EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 30 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; radiation of interference; according to the automotive directive 2004/104/EC; CISPR 25; immunity; according to the automotive directive 2004/104/EC; ISO 11452-2 HF radiated; 100 V/m; ISO 7637-2 pulse; severity level 4
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated30 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
radiation of interferenceaccording to the automotive directive 2004/104/EC
immunityaccording to the automotive directive 2004/104/EC
ISO 11452-2 HF radiated100 V/m
ISO 7637-2 pulseseverity level 4
Shock resistanceDIN EN 60068-2-27; 50 g (11 ms); DIN EN 61373; category 3
DIN EN 60068-2-2750 g (11 ms)
DIN EN 61373category 2
Vibration resistanceDIN EN 60068-2-6; 20 g (10...2000 Hz); DIN EN 61373; category 2
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]550
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]215.5
Housingcylindrical
Dimensions[mm] [mm]Ø 30 / L = 79.5
Materialsstainless steel (316L/1.4404); stainless steel (303/1.4305); PA; EPDM/X; FKM
Materials (wetted parts)stainless steel (303/1.4305); Al2O3 (ceramics); FKM
Min. pressure cycles100 million
Tightening torque[Nm] [Nm]25...35; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/4 external thread (DIN EN ISO 1179-2)
Process connection sealingFKM (DIN EN ISO 1179-2)
Restrictor element integratedno (can be retrofitted)

Remarks

Notescustomer-specific
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

PX9524: frequently asked questions

When can PX9524 be shipped?

PX9524 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PX9524 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PX9524 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PX9524, subject to availability and destination.

More IFM parts

IFM PX9524Price and lead time confirmed within 1 business day
Request a Quote