What is the IFM PV7804?

Particularly compact housing for use where space is restricted

Very high overpressure and vacuum resistance

Robust stainless steel housing with high shock and vibration resistance

Lifespan of more than 60 million pressure cycles

Two programmable switching outputs, one of them with IO-Link communication interface

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 2
Measuring range-1...10 bar; -14.5...145 psi; -100...1000 kPa; -0.1...1 MPa
-1...10 bar-14.5...145 psi
Process connectionthreaded connection G 1/8 external thread DIN EN ISO 1179-2 internal thread:M5

Application

Measuring elementmetallic thin film cell
Applicationfor industrial applications
Medialiquids and gases
Medium temperature[°C] [°C]-40...90
Min. burst pressure300 bar; 4350 psi; 30 MPa
300 bar4350 psi
Pressure rating25 bar; 360 psi; 2.5 MPa
25 bar360 psi
Note on pressure ratingstatic
Vacuum resistance-1000 mbar; -0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure; vacuum

Electrical data

Operating voltage[V] [V]18...30 DC
Current consumption[mA] [mA]< 15
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 0.3

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 2

Outputs

Total number of outputs2
Output signalswitching signal; IO-Link; (configurable)
Electrical designPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]< 170
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes

Measuring/setting range

Measuring range-1...10 bar; -14.5...145 psi; -100...1000 kPa; -0.1...1 MPa
-1...10 bar-14.5...145 psi
Set point SP-0.9...10 bar; -13.1...145 psi; -90...1000 kPa; -0.09...1 MPa
-0.9...10 bar-13.1...145 psi
Reset point rP-0.95...9.95 bar; -13.8...144.3 psi; -95...995 kPa; -0.095...0.995 MPa
-0.95...9.95 bar-13.8...144.3 psi
In steps of0.005 bar; 0.1 psi; 0.5 kPa; 0.0005 MPa
0.005 bar0.1 psi
Factory settingSP1 = 2.5 bar; rP1 = 2.3 bar; ou1 = Hno;; SP2 = 7.5 bar; rP2 = 7.3 bar; ou2 = Hno;; dS1/dS2 = 0 ms; dr1/dr2 = 0 ms; coF = 0 %; P-n = PnP; dAP= 60 ms
SP1 = 2.5 barrP1 = 2.3 bar
SP2 = 7.5 barrP2 = 7.3 bar
dS1/dS2 = 0 msdr1/dr2 = 0 ms
coF = 0 %P-n = PnP

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5 (nach DIN EN 61298-2)
Repeatability[% of the span] [% of the span]< ± 0,05; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,5; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity deviation[% of the span] [% of the span]< ± 0,1 (BFSL) / < ± 0,2 (LS)
Zero-point stabilisation[% of the span] [% of the span]IO-Link,; 0,25; (see operating instructions zero-point behaviour); switching output; 0,5
IO-Link,0,25; (see operating instructions zero-point behaviour)
switching output0,5
Hysteresis deviation[% of the span] [% of the span]< ± 0,2
Long-term stability[% of the span] [% of the span]< ± 0,1; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]< 0,1 (-25...90 °C) / < 0,2 (-40...-25 °C)

Response times

Response time[ms] [ms]< 3

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable; Function; Device diagnosis
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionDevice diagnosis
SIO modeyes
Required master port typeA
Process data analogue2
Process data binary2
Min. process cycle time[ms] [ms]5
Supported DeviceIDsdefault; 727
default727

Operating conditions

Ambient temperature[°C] [°C]-40...90
Storage temperature[°C] [°C]-40...100
ProtectionIP 67; IP 69K

Tests / approvals

EMCDIN EN 61326-1
Shock resistanceDIN EN 60068-2-27; 500 g (1 ms)
DIN EN 60068-2-27500 g (1 ms)
Vibration resistanceDIN EN 60068-2-6; 20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]667
UL approvalUL approval no.; J015; File number UL; E174189
UL approval no.J015
File number ULE174189
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]55
Housingcylindrical
Dimensions[mm] [mm]Ø 19 / L = 66
MaterialsProcess connection , measuring cell: stainless steel (630/1.4542/17-4 PH); M12-plug: stainless steel (316L/1.4404); M12-plug: acrylate, PEI; ventilation diaphragm: PTFE
Materials (wetted parts)Process connection , measuring cell: stainless steel (630/1.4542/17-4 PH); Sealing: FKM
Min. pressure cycles60 million; (at 1.2 times nominal pressure)
Tightening torque[Nm] [Nm]20...25; (recommended tightening torque; depends on the lubrication, the seal and the pressure load)
Process connectionthreaded connection G 1/8 external thread DIN EN ISO 1179-2 internal thread:M5
Process connection sealingFKM (DIN EN ISO 1179-2)
Restrictor element integratedno

Remarks

RemarksBFSL = Best Fit Straight Line; LS = limit value setting
Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A

PV7804: frequently asked questions

When can PV7804 be shipped?

PV7804 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PV7804 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PV7804 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PV7804, subject to availability and destination.