What is the IFM PQ3809?

Reliable monitoring of the system pressure in pneumatics and in compressed air systems

Very high overpressure and vacuum resistance

Clearly visible slanted LED display

Red/green display for clear identification of the acceptable range

With programmable switching output and analogue output

Convenient operation via buttons or parameter setting via IO-Link

Specifications

Product characteristics

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1
Measuring range-1...1 bar; -1000...1000 mbar; -14.6...14.6 psi; -29.4...29.4 inHg; -100...100 kPa
-1...1 bar-1000...1000 mbar
Process connectionthreaded connection G 1/8 internal thread internal thread:M5

Application

Special featureGold-plated contacts
Applicationfor industrial applications
Conditionally suitable forother media on request
Medium temperature[°C] [°C]0...60
Min. burst pressure30 bar; 435 psi; 886 inHg; 3000 kPa
30 bar435 psi
Note on min. burst pressuremax. overpressure on second pressure connection: 12 bar / 1200 kPa / 174 PSI / 354,4 inHg / 1,2 MPa
Pressure rating20 bar; 290 psi; 591 inHg; 2000 kPa
20 bar290 psi
Vacuum resistance-1000 mbar; -0.1 MPa
-1000 mbar-0.1 MPa
Type of pressurerelative pressure; differential pressure; vacuum

Electrical data

Operating voltage[V] [V]18...32 DC; (to SELV/PELV)
Current consumption[mA] [mA]< 50
Min. insulation resistance[MΩ] [MΩ]100; (500 V DC)
Protection classIII
Reverse polarity protectionyes
Overvoltage protectionyes; (< 40 V)
Power-on delay time[s] [s]0.5
Integrated watchdogyes

Inputs / outputs

Number of inputs and outputsNumber of digital outputs: 1; Number of analogue outputs: 1

Outputs

Total number of outputs2
Output signalswitching signal; analogue signal; IO-Link; (configurable)
Electrical designPNP
Number of digital outputs1
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]< 100
Number of analogue outputs1
Analogue current output[mA] [mA]4...20
Max. load[Ω] [Ω]500
Short-circuit protectionyes
Type of short-circuit protectionpulsed

Measuring/setting range

Measuring range-1...1 bar; -1000...1000 mbar; -14.6...14.6 psi; -29.4...29.4 inHg; -100...100 kPa
-1...1 bar-1000...1000 mbar
Set point SP-0.98...1 bar; -14.2...14.6 psi; -28.8...29.4 inHg; -98...100 kPa
-0.98...1 bar-14.2...14.6 psi
Reset point rP-0.99...0.99 bar; -14.4...14.4 psi; -29.1...29.1 inHg; -99...99 kPa
-0.99...0.99 bar-14.4...14.4 psi
In steps of0.01 bar; 0.2 psi; 0.3 inHg; 1 kPa
0.01 bar0.2 psi

Accuracy / deviations

Switch point accuracy[% of the span] [% of the span]< ± 0,5
Repeatability[% of the span] [% of the span]< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span] [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span] [% of the span]< ± 0,25
Long-term stability[% of the span] [% of the span]< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K] [% of the span / 10 K]0,2; (0...60 °C)
Temperature coefficient span[% of the span / 10 K] [% of the span / 10 K]0,2; (0...60 °C)

Response times

Response time[ms] [ms]< 6
Delay time programmable dS, dr[s] [s]0; 0,002...5
Step response time analogue output[ms] [ms]6

Software / programming

Parameter setting optionshysteresis / window; normally open / normally closed; analogue output; IO-Link; switching logic; switch-on/switch-off delay; Damping; Display unit

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9 FDIS
ProfilesSmart Sensor - SSP 0; Generic Profiled Sensor; Function; Device identification; Function; Process data variable
Smart Sensor - SSP 0Generic Profiled Sensor
FunctionProcess data variable
SIO modeyes
Required master port typeA
Process data analogue1
Process data binary2
Min. process cycle time[ms] [ms]2.3
Supported DeviceIDsdefault; 366
default366

Operating conditions

Ambient temperature[°C] [°C]0...70
Storage temperature[°C] [°C]-25...85
ProtectionIP 65

Tests / approvals

EMCDIN EN 61000-6-2; DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-27; 50 g (11 ms)
DIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-6; 20 g (10...2000 Hz)
DIN EN 60068-2-620 g (10...2000 Hz)
MTTF[years] [years]437
Pressure Equipment DirectiveSound engineering practice; can be used for group 2 fluids; group 1 fluids on request

Mechanical data

Weight[g] [g]87
Housingrectangular
Dimensions[mm] [mm]42 x 30 x 32
MaterialsPBT; FKM; polyester
Materials (wetted parts)brass; FKM; silicon (coated); PBT
Min. pressure cycles50 million
Process connectionthreaded connection G 1/8 internal thread internal thread:M5

Displays / operating elements

DisplayDisplay unit; 4 x LED, green; switching status; 1 x LED, yellow; function display; alphanumeric display, 4-digit; measured values; alphanumeric display, 4-digit
Display unitbar; kPa; psi; inHg
switching status1 x LED, yellow
function displayalphanumeric display, 4-digit
measured valuesalphanumeric display, 4-digit

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M8; coding: A; Contacts: gold-plated

PQ3809: frequently asked questions

When can PQ3809 be shipped?

PQ3809 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PQ3809 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PQ3809 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PQ3809, subject to availability and destination.