IFM KD001A

MPN
KD001A
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the IFM KD001A?

With combined AC/DC output and two-wire technology

Long sensing range of 60 mm

Easy setting of the sensing range via potentiometer

For applications in hazardous areas

Robust housing for use in harsh industrial environments

Specifications

Product characteristics

Output functionnormally open / normally closed; (selectable)
Sensing range[mm] [mm]60
Housingrectangular
Dimensions[mm] [mm]105 x 80 x 42

Electrical data

Operating voltage[V] [V]20...250 AC/DC
Protection classII
Reverse polarity protectionno
Measuring principlecapacitive

Outputs

Output functionnormally open / normally closed; (selectable)
Max. voltage drop switching output DC[V] [V]8
Max. voltage drop switching output AC[V] [V]10
Minimum load current[mA] [mA]5
Max. leakage current[mA] [mA]2.5 (250 V AC) / 1.7 (110 V AC) / 1.3 (24 V DC)
Permanent current rating of switching output AC[mA] [mA]130; (250 (...40 °C))
Permanent current rating of switching output DC[mA] [mA]130; (250 (...40 °C))
Short-time current rating of switching output[mA] [mA]1500; (20 ms / 0,5 Hz)
Switching frequency AC[Hz] [Hz]4
Switching frequency DC[Hz] [Hz]4
Notes on switching frequency[Hz] [Hz]only for resistive loads; 2 Hz for utilisation category AC-140
Short-circuit proofno
Overload protectionno

Detection zone

Sensing range[mm] [mm]60
Sensing range adjustableyes
Factory setting sensing range[mm] [mm]60
Real sensing range Sr[mm] [mm]60 ± 10 %

Accuracy / deviations

Correction factorglass: 0.4 / water: 1 / ceramics: 0.2 / PVC: 0.2
Hysteresis[% of Sr] [% of Sr]1...15
Switch point drift[% of Sr] [% of Sr]-15...15

Operating conditions

Ambient temperature[°C] [°C]-20...60
ProtectionIP 65
Increased immunityyes

Tests / approvals

ATEX markingII 3D Ex tc IIIC T90°C Dc X IP65
EMCEN 60947-5-2
MTTF[years] [years]270

Mechanical data

Weight[g] [g]281.5
Housingrectangular
Mountingnon-flush mountable
Dimensions[mm] [mm]105 x 80 x 42
MaterialsPPE modified; PA
Tightening torque[Nm] [Nm]housing screws: 0,9 Nm; screws: 4 Nm

Displays / operating elements

Displayswitching status; 1 x LED, yellow
switching status1 x LED, yellow

Electrical connection

Required protectionminiature fuse to IEC60127-2 sheet 1; ≤ 2 A; fast acting; Place the fuse outside the hazardous area.

Remarks

RemarksRecommendation: Check the safe functioning of the unit after a short circuit.
Pack quantity1 pcs.

Electrical connection

terminals0.34...2.5 mm²; Cable sheath: Ø 5...9 mm; Cable gland: M20 X 1.5

KD001A: frequently asked questions

When can KD001A be shipped?

KD001A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KD001A in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KD001A and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KD001A, subject to availability and destination.

More IFM parts

IFM KD001APrice and lead time confirmed within 1 business day
Request a Quote