What is the IFM II5983?

Long sensing range for use in conveying

Flexible use thanks to large operating temperature range

Reliable transmission of the distance as linearised process value via IO-Link

Normally closed / normally open and PNP/NPN adjustable via IO-Link

Specifications

Product characteristics

Electrical designPNP/NPN; (parameterisable)
Output functionnormally open / normally closed; (parameterisable)
Communication interfaceIO-Link
Housingthreaded type
Dimensions[mm] [mm]M30 x 1.5 / L = 65

Electrical data

Operating voltage[V] [V]10...30 DC
Current consumption[mA] [mA]< 15
Protection classIII
Reverse polarity protectionyes

Outputs

Electrical designPNP/NPN; (parameterisable)
Output functionnormally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V] [V]2.5
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]100
Short-circuit protectionyes
Overload protectionyes

Detection zone

Switch point IO-Link[mm] [mm]2.4...12.1; (parameterisable)
Measuring range IO-Link[mm] [mm]1.3...13

Accuracy / deviations

Correction factorsteel: 1 / stainless steel: 0.7 / brass: 0.5 / aluminium: 0.5 / copper: 0.4
Hysteresis[% of Sr] [% of Sr]3...15
Note on hysteresisparameterisable
Linearity error IO-Link[%] [%]± 2; (of the final value of the measuring range)
Repeatability analogue output[%] [%]± 1; (of the final value of the measuring range)
Temperature coefficient[%/K vom MEW] [%/K vom MEW]± 0,3
Temperature drift± 10 %; (of the final value of the measuring range)

Interfaces

Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
ProfilesSmart Sensor - SSP 0; Generic Profiled Sensor; Common - I&D; Identification and Diagnosis; Function; Multiple switching signal; Function; Teach channel
Smart Sensor - SSP 0Generic Profiled Sensor
Common - I&DIdentification and Diagnosis
FunctionTeach channel
SIO modeyes
Required master port typeA
Min. process cycle time[ms] [ms]3.2
IO-Link process data (cyclical)process value; 16; device status; 4; binary switching information; 2
process value16
device status4
binary switching information2
IO-Link functions (acyclical)switching cycles counter; switch-on cycle counter; operating hours counter; internal temperature; application specific tag
Supported DeviceIDsdefault; 1344
default1344
NoteFor further information please see the IODD PDF file under "Downloads"

Operating conditions

Ambient temperature[°C] [°C]-40...85
ProtectionIP 65; IP 66; IP 67; IP 68; IP 69K

Tests / approvals

EMCEN 61000-4-2 ESD; 4 kV CD / 8 kV AD; EN 61000-4-3 HF radiated; 10 V/m; EN 61000-4-4 Burst; 2 kV; EN 61000-4-6 HF conducted; 10 V; EN 55011; class B
EN 61000-4-2 ESD4 kV CD / 8 kV AD
EN 61000-4-3 HF radiated10 V/m
EN 61000-4-4 Burst2 kV
EN 61000-4-6 HF conducted10 V
EN 55011class B
Vibration resistanceEN 60068-2-6 Fc; 20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes
EN 60068-2-6 Fc20 g (10...3000 Hz) / 50 sweep cycles, 1 octave per minute, in 3 axes
Shock resistanceEN 60068-2-27 Ea; 100 g 11 ms half-sine; 3 shocks each in every direction of the 3 coordinate axes
EN 60068-2-27 Ea40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Continuous shock resistanceEN 60068-2-27 Ea; 40 g 6 ms; 4000 shocks each in every direction of the 3 coordinate axes
Fast temperature changeEN 60068-2-14 Na; TA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
EN 60068-2-14 NaTA = -40 °C; TB = 85 °C; t1 = 30 min; t2 = < 10 s; 50 cycles
MTTF[years] [years]599
Embedded software includedyes
UL approvalTa; -25...70 °C; Enclosure type; Type 1; power supply; Limited Voltage/Current; UL approval no.; A034; File number UL; E174191
Ta-25...70 °C
Enclosure typeType 1
power supplyLimited Voltage/Current
UL approval no.A034
File number ULE174191

Mechanical data

Weight[g] [g]120.9
Housingthreaded type
Mountingflush mountable
Dimensions[mm] [mm]M30 x 1.5 / L = 65
Thread designationM30 x 1.5
Materialshousing: brass white bronze coated; sensing face: PBT orange; LED window: PEI; lock nuts: brass white bronze coated

Displays / operating elements

Displayswitching status; 4 x LED, yellow lights
switching status4 x LED, yellow lights

Accessories

Items suppliedlock nuts: 2

Remarks

Pack quantity1 pcs.

Electrical connection - plug

Connector1 x M12; coding: A

II5983: frequently asked questions

When can II5983 be shipped?

II5983 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up II5983 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for II5983 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for II5983, subject to availability and destination.

More IFM parts

IFM II5983Price and lead time confirmed within 1 business day
Request a Quote