IFM E40581

Replacement electronics SM Foodmag series

MPN
E40581
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare IFM parts? We buy surplus →

What is the IFM E40581?

Hygienic design for the requirements of the food and beverage industry

Reduces costs and effort when replacing defective display units

Specifications

Application

Special featureGold-plated contacts
Applicationfood and beverage industry

Electrical data

Operating voltage[V] [V]18...32 DC
Current consumption[mA] [mA]250; (24V)
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s] [s]< 5

Inputs / outputs

Total number of inputs and outputs2

Inputs

InputsOUT2; external totaliser reset
OUT2external totaliser reset

Outputs

Total number of outputs2
Output signalOUT1; pulse signal; totaliser switching signal; diagnostic signal; IO-Link; OUT2; analogue signal; pulse signal; totaliser switching signal; diagnostic signal
OUT1pulse signal; totaliser switching signal; diagnostic signal; IO-Link
OUT2analogue signal; pulse signal; totaliser switching signal; diagnostic signal
Electrical designPNP/NPN
Pulse outputflow rate meter
Short-circuit protectionyes
Type of short-circuit protectionpulsed
Overload protectionyes
Number of analogue outputs1
Analogue current output[mA] [mA]4...20; (skalierbar)
Max. load[Ω] [Ω]500
Resolution of analogue output0.38 µA
Number of digital outputs2
Max. voltage drop switching output DC[V] [V]2
Permanent current rating of switching output DC[mA] [mA]100
Switching frequency DC[Hz] [Hz]0...10000

Software / programming

Diagnostic functionsdirection of flow detection; liquid detection

Interfaces

Communication interfaceIO-Link
Transmission typeCOM3 (230,4 kBaud)
IO-Link revision1.1.3
SDCI standardIEC 61131-9
ProfilesCommon - I&D; Identification and Diagnosis; Smart Sensor - SSP 4.3.4; Measuring and Switching Sensor, floating point, 4 channel
Common - I&DIdentification and Diagnosis
Smart Sensor - SSP 4.3.4Measuring and Switching Sensor, floating point, 4 channel
SIO modeyes
Required master port typeA
Process data analogue6
Process data binary8
Min. process cycle time[ms] [ms]1.9
IO-Link process data (cyclical)totaliser; 32; flow; 32; temperature; 32; conductivity; 32; status; 4; binary switching information; 8
totaliser32
flow32
temperature32
conductivity32
status4
binary switching information8
IO-Link functions (acyclical)direction of flow detection; totaliser; memory; operating hours counter; internal temperature; simulation function

Operating conditions

Ambient temperature-20...65 °C; -4...149 °F
-20...65 °C-4...149 °F
Storage temperature-20...80 °C; -4...176 °F
-20...80 °C-4...176 °F
ProtectionIP 67; IP 69

Tests / approvals

EMCDIN 61326-1
Shock resistanceDIN IEC 68-2-27; 20 g (18ms)
DIN IEC 68-2-2720 g (18ms)
Vibration resistanceDIN IEC 68-2-6; 5 g (10...2000Hz)
DIN IEC 68-2-65 g (10...2000Hz)

Mechanical data

Weight[g] [g]922
Housingrectangular
Dimensions[mm] [mm]92.6 x 130.6 x 59
Materialselectronics: stainless steel (316L/1.4404); Display: polysulfone; Display-Sealing: FKM; LED ring: PP

Displays / operating elements

4capacitive pushbuttons
Displayprocess value; full graphics TFT display, multi-colour 3,5" 320 x 240 Pixel; display layouts: 4; display rotation: 4 x 90°; operating status; LED ring, three-colour
process valuefull graphics TFT display, multi-colour 3,5" 320 x 240 Pixel
operating statusLED ring, three-colour
LanguageGerman; English; Spanish; French; Italian; Japanese; Korean; Portuguese; Chinese
Operating elements4; capacitive pushbuttons

Accessories

Items suppliedreplacement electronics: 1 x (92,6 x 130,6 x 59 mm), for SMFx2x; hexagon nuts: 4 x M5

Remarks

Pack quantity1 pcs.

Electrical connection

Connector1 x M12; coding: A; Contacts: gold-plated

E40581: frequently asked questions

When can E40581 be shipped?

E40581 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up E40581 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for E40581 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for E40581, subject to availability and destination.

More IFM parts

IFM E40581Price and lead time confirmed within 1 business day
Request a Quote