Quick facts
| Availability | Confirmed on request |
| Category | PCB solutions |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can AC2709 be shipped?
AC2709 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up AC2709 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for AC2709 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for AC2709, subject to availability and destination.
For installation in small housings, control cabinets and operator panels Simple and fast wiring by means of wire strands Particularly space-saving design For integration of mechanical switches into AS-i networks AS-i connection for four control and signalling devices
Specifications
Application
| Application | For integration of mechanical switches into AS-i networks |
Electrical data
| Operating voltage[V] [V] | 26.5...31.6 DC |
| Max. current consumption from AS-i[mA] [mA] | 250 |
| Max. current load total[A] [A] | 0.2; (total current for all inputs and outputs supplied from AS-i: 200 mA) |
Inputs / outputs
| Number of inputs and outputs | Number of digital inputs: 4; Number of digital outputs: 4 |
Inputs
| Number of digital inputs | 4 |
| Input circuit of digital inputs | PNP |
| Sensor supply of the inputs | AS-i |
| Power supply[V] [V] | 15...30; (DC) |
| Max. total current rating of inputs[mA] [mA] | 200 |
| Input current High[mA] [mA] | > 3 |
| Input current Low[mA] [mA] | < 1.5 |
| Switching level high[V] [V] | > 10 |
| Digital inputs protected against short circuits | yes |
Outputs
| Electrical design | PNP |
| Number of digital outputs | 4 |
| Circuit | PNP |
| Max. current load per output[mA] [mA] | 50 |
| Short-circuit proof | yes |
| Electrically separated | yes |
| Actuator supply outputs | AS-i |
Operating conditions
| Ambient temperature[°C] [°C] | -25...60 |
| Protection | IP 20 |
Tests / approvals
| EMC | EN 50295 |
| MTTF[years] [years] | 322 |
AS-i classification
| AS-i version | 2.1 |
| Extended addressing mode | no |
| AS-i master profile | M2; M3; M4 |
| AS-i profile | S-7.0.F |
| AS-i I/O configuration[hex] [hex] | 7 |
| AS-i ID code[hex] [hex] | 0.F |
Mechanical data
| Weight[g] [g] | 115 |
| Housing | rectangular |
| Type of mounting | for Moeller housing RMQ-Titan: I3M, I4M, I6M |
Displays / operating elements
| Display | operation; LED, green |
| operation | LED, green |
Remarks
| Remarks | The PCB can also be integrated into an RMQ22 housing.; Do not connect any of the following points to an external potential:; O-, I+, I1, I2, I3, I4; The connections are electrically connected with the AS-i cable.; Install the unit so that exposed parts cannot be touched. |
| Pack quantity | 1 pcs. |
Electrical connection
| Cable | 0.2 m |