Honeywell SPXCDULNG1

XCD Gas Detector, includes hydrogen EC sensor cartridge 0 to 1000ppm

MPN
SPXCDULNG1
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Honeywell parts? We buy surplus →

What is the Honeywell SPXCDULNG1?

Part of Honeywell's Sensepoint XCD Gas Detector range. Transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres - indoors and outdoors.

Product Overiew:

Sensepoint XCD now has remote monitoring capabilities for its toxic and Oxygen sensors. Its remote capability is designed to offer excellent flexibility of use and is an ideal solution for hard-to-reach locations or areas where the transmitter needs to be separate from the sensor. With remote toxic and Oxygen sensor mounting of up to 100 feet (30m) away from the transmitter, Sensepoint XCD provides a robust monitoring solution even in challenging environments where detection is difficult, including applications where the point of detection is in an area that is not easily accessible or where the detector would not be visible, like in high or low level concealed areas or outside a room being monitored.

Sensepoint XCD is easy to use. The sensor simply plugs into the bottom of the transmitter and the transmitter automatically configures itself accordingly. Users can modify detector operation using the LCD and magnet switches without ever needing to open the unit. This enables one-man, non-intrusive operation and reduces routine maintenance time and costs.

A tri-color backlit LCD clearly indicates the unit’s status at a glance, even from a distance. A steady green backlight indicates normal operation, flashing yellow indicates fault and flashing red indicates an alarm.

All detectors are supplied pre-configured and include two programmable alarm relays, one programmable fault relay as well as an industry standard 4-20mA output (sink or source selectable) and MODBUS communication. The scale, range, relay operation, alarm set point and electronic tag number of the detector can be adjusted using the transmitter's LCD and non-intrusive magnetic switches. Outputs are automatically inhibited during adjustment, thereby reducing the risk of false alarm at the control panel during maintenance.

Additional Features and Benefits:

All-In-One Gas Monitoring Solution:

Flammable (catalytic or infrared), toxic and oxygen versions available

Serves new/retrofit, indoor/outdoor applications

Stainless steel or aluminum explosion-proof housing options

IP66 as standard

Proven and Reliable Sensor Technology:

SurecellTM electrochemical sensors

Poison immune infrared sensors

Poison resistant catalytic bead sensors

Long life sensors

Global Approvals:

US and Latin America, European, Canadian and Asian

Compliant with UL, INMETRO, ATEX, IECEx, CSA, KTL, PA, GB and CCCF standards

Easy to Use:

User friendly and intuitive tri-color backlit display with digits, bar graph and icons

Fully configurable via magnetic switches

Optional remote sensor mounting

Selectable sink or source 4-20mA output

Auto-inhibit during maintenance

MODBUS communications for remote diagnostics/configuration

Cost Effective:

Common transmitter platform

Minimal training required

Reduced spares

Non-intrusive, one-man operation

Plug-in sensor replacement

MODBUS multi drop option offers cabling savings

Simple Installation:

Plug-in display module removes to give access to terminal area

Integral mounting bracket

2 x M20 or ¾” NPT cable/conduit entries

Removable plug/socket type terminal blocks for

Sink/source switch to suit preferred wiring topology

Integral mounting plate attaches to surface, horizontal or vertical piping

Features & Benefits:

All-in-one gas monitoring solution

Proven SurecellTM electrochemical sensors

Global approvals

Quick Specs:

Input voltage range: 16 to 32 VDC (24 VDC nominal)

Communication: RS485, MODBUS RTU

Certified temperature range: 40° to +149°F (-40° to +65°C)

Fire and Gas Consultancy Services

Even the best products deserve expert maintenance!

Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.

Explore our fixed, portable, and high-tech support services now!

Honeywell SPXCDULNG1 — XCD Gas Detector, includes hydrogen EC sensor cartridge 0 to 1000ppm (Sensepoint XCD Gas Detector). PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.

Specifications

Product

LifecycleActive
DescriptionXCD Gas Detector, includes hydrogen EC sensor cartridge 0 to 1000ppm
Product seriesSensepoint XCD Gas Detector

SPXCDULNG1: frequently asked questions

When can SPXCDULNG1 be shipped?

SPXCDULNG1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up SPXCDULNG1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for SPXCDULNG1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SPXCDULNG1, subject to availability and destination.

More Honeywell parts

Honeywell SPXCDULNA2R – XCD DIV2 cCSAus LM25 NH3 0-50PPM JB
Honeywell
SPXCDULNA2R

XCD DIV2 cCSAus LM25 NH3 0-50PPM JB

Honeywell SPXCDULNA2RM – Explosion Proof Transmitter (EC), 4-20mA, 3 Relays, Modbus, Sensepoint Toxic Sensor, Ammonia (NH3) 0-50 ppm Aluminum Enclosure, Class I, Div 2 w Junction Box
Honeywell
SPXCDULNA2RM

Explosion Proof Transmitter (EC), 4-20mA, 3 Relays, Modbus, Sensepoint Toxic Sensor, Ammonia (NH3) 0-50 ppm Aluminum Enclosure, Class I, Div 2 w Junction Box

Honeywell SPXCDULNB1M – ULcULINMETRO approved SP XCD Carbon dioxide (CO2) IR 0-2% Vol. with LM25, 34NPT Entry with Modbus
Honeywell
SPXCDULNB1M

ULcULINMETRO approved SP XCD Carbon dioxide (CO2) IR 0-2% Vol. with LM25, 34NPT Entry with Modbus

Honeywell SPXCDULNC2 – XCD DIV2 cCSAus LM25 CO 0-200PPM
Honeywell
SPXCDULNC2

XCD DIV2 cCSAus LM25 CO 0-200PPM

Honeywell SPXCDULNPX – XCD Gas Detector, includes infrared propane sensor cartridge 0 to 100%LEL
Honeywell
SPXCDULNPX

XCD Gas Detector, includes infrared propane sensor cartridge 0 to 100%LEL

Honeywell SPXCDULNRFD – XCD RFD Transmitter, 4 to 20 mA output, cCSAusINMETRO, 3 x 34 NPT entries, painted LM25
Honeywell
SPXCDULNRFD

XCD RFD Transmitter, 4 to 20 mA output, cCSAusINMETRO, 3 x 34 NPT entries, painted LM25

Honeywell SPXCDULNRFDM – XCD RFD Transmitter: 4 to 20 mA and Modbus output: cCSAusINMETRO: 3 x 34' NPT entries: painted LM25
Honeywell
SPXCDULNRFDM

XCD RFD Transmitter: 4 to 20 mA and Modbus output: cCSAusINMETRO: 3 x 34' NPT entries: painted LM25

Honeywell SPXCDULNRXM – ULINMETRO approved SP XCD Flammable Methane (CH4) IR 0-100% LEL (20 to 100% LEL, 10% LEL) with LM25, 34NPT with Modbus
Honeywell
SPXCDULNRXM

ULINMETRO approved SP XCD Flammable Methane (CH4) IR 0-100% LEL (20 to 100% LEL, 10% LEL) with LM25, 34NPT with Modbus

Honeywell SPXCDULNG1Price and lead time confirmed within 1 business day
Request a Quote