Honeywell – SL-DA4R-P SL-DA4R Series Smoke Duct Detector
Discontinued by Honeywell — we can still source the original SL-DA4R-P (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Honeywell Building Sensors & Detectors |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
Can I still buy the SL-DA4R-P now that it is discontinued?
Yes. Honeywell has discontinued the SL-DA4R-P, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can SL-DA4R-P be shipped?
SL-DA4R-P is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up SL-DA4R-P in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for SL-DA4R-P and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for SL-DA4R-P, subject to availability and destination.
The SL-DA4R Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications. The unit is designed to prevent the recirculation or spread of smoke by air handling systems, fans, and blowers. Complete systems may be shut down via the unit’s on-board alarm contact in the event of smoke detection. The SL-DA4R is designed and built to meet all local code requirements, as well as the NFPA and ICC standards regarding HVAC supply and return duct smoke detectors. Output terminals are provided for a wide range of remote accessories such as horns, strobes, remote status indicators and test key switches or push buttons. The SL-DA4R includes many features that represent true innovations from current generation duct smoke detectors. Our traditional installer/servicer-friendly approach has been closely followed and expanded throughout the SLDA4R. This philosophy provides a new level of efficiency in after-purchase value to both the installer/servicer and end user. Our attention to detail has yielded a host of “No-Tools Required” features, as well as a multi-application performance level as yet unmatched in the industry. The key features below detail many of the customer-driven innovations incorporated in the SL-DA4R Series. Innovative product combined with unsurpassed customer service equals the right combination for all of your projects.
Engineers & Architects Specifications
Air duct smoke detectors shall be Air Products and Controls Inc. SL-DA4R Series.
For photoelectric detectors the model number is SLDA4R-P. The detectors shall be listed by Underwriters Laboratories per UL 268A.
The detectors shall operate at air velocities from 100 feet per minute to 4,000 feet per minute and at temperatures of no greater than 140°F (60°C).
Visual indication of alarm must be provided on the detector front. A manual alarm relay/test switch located on the front of the device shall be provided.
Detector head shall not require additional filters or screens which must be maintained, and control board shall include both a standby and alarm visual indications
The housing shall contain a detector base which will accept photoelectric or ionization detector heads as well as a means of detector addressing.
Terminal connections shall be of the screw type, a minimum of #6 screw (#12 to #22 AWG compatible). Terminals shall be provided for remote pilot, remote alarm indications, strobe/horn, and remote test switch. All wiring must comply with local codes and regulations.
A method of smoke testing the detector without removing the cover must be provided
All unit and remote accessory connection designations must be permanently affixed to the unit.
Cover and sampling/exhaust tube installation or removal must not require the use of tools.
Sample and exhaust tubes shall be capable of removal/ installation from the front and/or rear of the detector for inspection/maintenance. Features & Benefits:
Low-Flow Technology: Both Ionization and Photoelectric models Listed for velocities between 100-4000 ft./min
Both Ionization and Photoelectric models listed for high temperature applications
Operating voltages: 24VAC or 24VDC
Units supplied with slide-in XPERT Card for easy device addressing
Patent pending “No-Tools Required” front or rear loading and removing sampling/exhaust tubes
Patent pending ”Test Port Valve” allows for aerosol smoke testing without cover removal
Clear cover fitted with four captive “No-Tools Required” thumbscrews
Instantaneous cover removal trouble indication
In-line terminal block for easier wiring
Steady red LED on detector head indicates alarm operation
More wiring space than competitive models
Footprint allows easy retrofit in many applications without additional drilling
Over 15 remote accessories available
Duct wall gaskets on back of enclosure are pre-installed
Compatible with the WP-2000 weatherproof enclosure
Built-in alarm relay test switch
Unit includes green pilot and red alarm visual indicators
External mounting tabs do not require cover removal to install
Colored cover gasket indicates proper cover seal
Compact, lightweight size means easy handling, lower shipping costs
One set of 15A form “C” alarm contacts
Large terminal connection screws
XP95A interchangeable “plug-in” UL268 photoelectric or ionization heads
Advanced detector head design yields internal dust filtering
No additional screens or filters to clean
Compatible with fire alarm systems utilizing Apollo XP95 and/or Discovery protocol
Ionization and Photoelectric versions available
Complete wiring details permanently attached to unit
Honeywell SL-DA4R-P — The SL-DA4R Series Smoke Duct Detector is the latest analog addressable innovation for early detection of smoke and products of combustion present in air moving through HVAC ducts in Commercial, Industrial, and Residential applications. Discontinued by Honeywell — no longer in the current range. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Discontinued by Honeywell |
More Honeywell parts
Available on requestSKE-MIC SKE-Series Microphone
Available on requestSKE-V70 SKE-V70 Speaker Circuit Voltage Converter
Available on requestSKF-SRD SKF System Record Document Cabinet
Available on requestSL-DAA-P SL-DAA Series Duct Smoke Detector