What is the Honeywell PUB1012S-ILC/U?

\Spyder® BACnet® PUB programmable controllers are designed to control HVAC equipment. These controllers provide many options and advanced system features that allow state-of-the-art commercial building control. Each controller is programmable and configurable through software. These controllers are for use in Variable Air Volume (VAV), Unitary, and advanced HVAC applications. Each controller has flexible, universal inputs for external sensors, digital inputs, and a combination of analog and digital Triac outputs. Features & Benefits:

Each controller communicates via an EIA-485 BACnet MS/TP network communications network, capable of baud rates between 9.6 and 115.2 kilobits

Controllers are field-mountable to either a panel or a DIN rail

Rated Voltage: 20–30V AC; 50/60 Hz

LED provides status for normal operation, controller download process, alarms, manual mode, and error conditionsCertifications:

UL/cUL (E87741) listed under UL916 (Standard for Open

Energy Management Equipment) with plenum rating.

CSA (LR95329-3) listed.

Meets FCC Part 15, Subpart B, Class B (radiated

emissions) requirements.

Meets Canadian standard C108.8 (radiated emissions).

EMC Directive: 2014/30/EU:

Standards Applied:

— IEC 61000-4-8:2009

— IEC 61000-4-11:2004

— EN 61000-6-1: 2007; EN 61000-6-3:2007/A1:2011;

EN 61000-6-3:2007/A1:2011/AC: 2012

— EN 60730-2-9: 2010, EN 60730-2-14: 1997 +

EN60730-2-14/A1: 2001.

— In conjunction with EN 60730-2-9:2010 and in

conjunction with EN 60730-2-14:1997 and

amendments: EN 60730-1: 2000 + A1: 2004 + A16:

2007 + A2: 2008 -Annex H.26.

RoHS Directive: 2011/65/EU

Standards Applied:

— EN 50581: 2012

BTL B-ASC (BACnet Testing Laboratories, BACnet

Application Specific Controller)

Honeywell PUB1012S-ILC/U — Spyder® BACnet® PUB programmable controllers are designed to control HVAC equipment. These controllers provide many options and advanced system features that allow state-of-the-art commercial building control. Discontinued by Honeywell — no longer in the current range. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.

Specifications

Product

LifecycleDiscontinued by Honeywell

Ordering codes

Part numbers on this product pagePUB1012S-ILC/U, PUB1012S/U, PUB4024S-ILC/U, PUB4024S/U, PUB6438S-ILC/U, PUB6438S/U, PUB6438SR-ILC/U, PUB6438SR/U

PUB1012S-ILC/U: frequently asked questions

Can I still buy the PUB1012S-ILC/U now that it is discontinued?

Yes. Honeywell has discontinued the PUB1012S-ILC/U, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can PUB1012S-ILC/U be shipped?

PUB1012S-ILC/U is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up PUB1012S-ILC/U in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for PUB1012S-ILC/U and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for PUB1012S-ILC/U, subject to availability and destination.

More Honeywell parts

Honeywell PU-A0005-1 – PU AC/DC Converter Power Supply
Honeywell
PU-A0005-1

PU AC/DC Converter Power Supply

Honeywell PU-U002-2 – Power Supply Set
Honeywell
PU-U002-2

Power Supply Set

Honeywell PUB0C2A0A1 – S100 Ssv, 2" Ansi 150 RF Flg, LP, 1-2#
Honeywell
PUB0C2A0A1

S100 Ssv, 2" Ansi 150 RF Flg, LP, 1-2#

Honeywell PUB4024S – PUB/PVB Series BACnet MS/TP Controller
Honeywell
PUB4024S

PUB/PVB Series BACnet MS/TP Controller

Honeywell PUC00016-EM2 – PUC - I/O Expansion Module
Honeywell
PUC00016-EM2

PUC - I/O Expansion Module

Honeywell PUC5533-PB2 – PUC...PB2 Series BACnet MS/TP Controller
Honeywell
PUC5533-PB2

PUC...PB2 Series BACnet MS/TP Controller

Honeywell PUB1012S-ILC/UPrice and lead time confirmed within 1 business day
Request a Quote