Honeywell GWCZI-95
Conventional Zone Interface Device
- MPN
- GWCZI-95
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Honeywell GWCZI-95?
Conventional zone interface devices are designed as the interface between the 600 Series and ILI95-E3 Series® fire alarm control panel's (FACPs) analog circuits and normally open contact devices or conventional smoke detectors. Conventional zone interface devices monitor up to 25 conventional detectors. You can use conventional zone interface devices with Style B, C, D, or E wiring.
Conventional zone interface devices can monitor up to 25 conventional smoke detectors via a 3-wire circuit. Conventional zone interface devices act as a remotely located conventional zone. They provide a supervised circuit to connect to conventional-type devices such as smoke detectors or contact devices. If any detector on the device's circuit goes into alarm, it will report its own address to the main control panel via the analog circuit, and the FACP will initiate the programmed response. The LEDs on the conventional detector and conventional zone interface devices will both light, indicating that the devices are in alarm.
If trouble is detected on the monitored circuit, the conventional zone interface devices will report the trouble condition to the FACP. Conventional zone interface devices will detect trouble from either the field wiring or a connected device. Conventional zone interface devices can be either surface- or flush-mounted and include an LED for annunciation. Conventional zone interface devices mount in a standard 4x4.688 inch (10.16x11.908 cm) or double-gang electrical backbox. They should be mounted in an easily accessible location, so that the built-in LED indicators may be easily seen and display the proper connection and device activation. Features & Benefits:
Provides an LED for alarm annunciation
Uses either surface- or flush-mounted
Field-programmable
Contains screw terminals for field-wiring connectionsCertifications:
UL Listed: S521
FM Approved
FDNY: Approved
CSFM: 7300-1703:0135
ISO 9001 Certification
Honeywell Gamewell-FCI GWCZI-95 — Conventional zone interface devices are designed as the interface between the 600 Series and ILI95-E3 Series® fire alarm control panel's (FACPs) analog circuits and normally open contact devices or conventional smoke detectors. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Active |
| Brand line | Gamewell-FCI |
Others
| Brand | Gamewell-FCI |
No matching specifications
GWCZI-95: frequently asked questions
When can GWCZI-95 be shipped?
GWCZI-95 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up GWCZI-95 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for GWCZI-95 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for GWCZI-95, subject to availability and destination.