Honeywell – FMM-1-AUS Flashscan Intelligent Addressable Monitor Module
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Honeywell Fire Alarm Panels & Modules |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can FMM-1-AUS be shipped?
FMM-1-AUS is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up FMM-1-AUS in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for FMM-1-AUS and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for FMM-1-AUS, subject to availability and destination.
FMM-1 Monitor Module is a standard-sized module (typically mounts to a 10.16 cm square box) that supervises a circuit of dry-contact input devices.
Features & Benefits:
The FMM-1 Monitor Module is intended for use in intelligent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Device Circuit (IDC) for normally-open-contact fire alarm and supervisory devices. The module has a panel-controlled LED indicator. The FMM-1 can be used to replace MMX-1 modules.
FMM-1 is used to monitor a zone of four-wire smoke detectors, manual normally open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an typical 2-wire initiating circuit configuration or 4-wire fault tolerant initiating circuit configuration. A 47K Ohm End-of-Line Resistor (provided) terminates the circuit. No resistor is required for supervision of the circuit.
Note: The listings and approvals below apply to the module specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.
Certifications:
SAI Global : License SMKH25312
New Zealand Equipment Register. Listing #NI/609
Honeywell NOTIFIER FMM-1-AUS — Addressable Monitor Module. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Active |
| Brand line | NOTIFIER |
Others
| Brand | NOTIFIER |
Ordering codes
| Part numbers on this product page | FMM-1-AUS, FMM-1-AUS/N |
More Honeywell parts
Available on requestFML-E3 Fiber Loop Module, Fibre-Optic Multi Mode
Available on requestFMM-4-20 FMM-4-20 Analog Input Module
Available on requestFOLC-9C Fiber Optic Lens CARTR/COUPLR (9 Degr)