Available on request

Honeywell – DACM-DYNET Network Integration

MPN: DACM-DYNET · Brand: Honeywell
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryHoneywell Building Management Systems (BMS)
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can DACM-DYNET be shipped?

DACM-DYNET is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up DACM-DYNET in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for DACM-DYNET and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for DACM-DYNET, subject to availability and destination.

DDNG485 - RS-485/DMX512 Gateway

The Scene Select II DDNG485 is a flexible network communications bridge designed for RS-485 networks. The two opto-isolated RS-485 ports enable the DDNG485 to implement a trunk and spur topology on large project sites, with the bridge providing a high-speed backbone opto-coupled to many lower speed spurs.

Route Scene Select II to third-party systems – Such as audio-visual, Modbus meters, and building automation systems, providing an integrated approach to total building control and energy management.

DMX512 mode – Transmit or receive up to 512 channels of DMX with automatic Scene Select II conversion and task triggering. Provides temporary control of house lights from the DMX console in an auditorium scenario.

Electrical fault isolation – Faults can be isolated to individual network spurs.

Internal controls – Programmable logic controller capable of comprehensive conditional and sequential logic and arithmetic function processing, packet filtering, and Scene Select II to Scene Select II 2 translation.

Flexible mounting solution – DIN rail mountable, designed to be installed into a distribution board or other electrical enclosure.

PDEG - Ethernet Gateway

The Scene Select II PDEG provides a multipurpose Ethernet connection to a Philips lighting control system. It supports access to the lighting system via a dedicated Philips app as well as providing a web interface delivering access to the inbuilt timeclock and schedule editor functions. It provides bridging functionality between Ethernet backbone and the Scene Select II fieldbus devices.

Large storage capacity - The device stores large project files internally, which apps use to automatically configure their settings. This saves configuration time and ensures accuracy for phone and tablet control.

Built-in web server - Allows the user to edit and check system settings via the Network Hardware Checker and System Roll Call tools.

No technical skills needed - Inbuilt timeclock and schedule manager allow the user to manage operation and task scheduling without advanced technical knowledge.

Powerful custom task engine - Allows users or third-party systems to run macros, such as ‘After Hours’, ‘Shut Down’, ‘Welcome’ and more.

Advanced interoperability - Supports management of Scene Select II and Philips PoE fittings on a single system.

PDDEG-S - Ethernet Gateway - Supervisor

Secure remote connection to the Dynalite System The Scene Select II PDDEG-S provides gateway services between Ethernet and Scene Select II devices, enabling secure online access to the Philips lighting control system. The gateway enables lighting control via a dedicated Philips app, and access to the timeclock, schedule editor and diagnostic functions via an inbuilt web server.

The Scene Select II PDDEG-S provides gateway services between Ethernet and Scene Select II devices, enabling secure online access to the Philips lighting control system.

The gateway enables lighting control via a dedicated Philips app, and access to the timeclock, schedule editor and diagnostic functions via an inbuilt web server.

System supervisory functions – Includes online/offline status reporting for connected devices, network traffic logging, secure remote firmware update and lighting control metrics. Inbuilt timeclock and schedule manager allow the user to manage automated operations and task scheduling.

Multiple integration options – Supports TCP/UDP, IPv4/IPv6, unicast/multicast/broadcast, Scene Select II1, Scene Select II2, Fidelio, BACnet*, and ‘Text and Binary Integration’ protocols. Capable of supporting hundreds of socket connections concurrently.

Flexible connectivity options – provides secure cloud connectivity to the building with user configurable routing and a choice of RS-485 and Ethernet bridging functions.

Powerful custom task engine – Allows users or third-party systems to run macros such as ‘After Hours’, ‘Shut Down’, ‘Welcome’ and more.

Web server and app access – Enables remote access for lighting control, schedule editing and device configuration.

Secure connection to Dynalite controllers – Each PDDEG-S supports encrypted communication with up to 25 Ethernet-equipped controllers. including the DDBC320-DALI and DDRC-GRMS-E.

* BACnet integration requires additional license, see specification sheet for ordering codes.

Honeywell Honeywell Lighting Controls DACM-DYNET — Bringing all the different devices together, Scene Select II supports a range of network devices that are useful in creating a problem-free installation. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.

Specifications

Product

LifecycleActive
Brand lineHoneywell Lighting Controls

Others

BrandHoneywell Lighting Controls

Ordering codes

Part numbers on this product pageDACM-DYNET, DDNG485, PDDEG-S, PDDEG-S 10K LICENC, PDDEG-S 1K LICENCE, PDDEG-S 5K LICENCE, PDEG, PDTS
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Honeywell parts

DA2-60 60W Building Occupant Warning SystemAvailable on requestDA2-60 60W Building Occupant Warning System
MPN: DA2-60 · Honeywell
Price on request
Request a quote
DA74C-1A Rotatable Connector PieceAvailable on requestDA74C-1A Rotatable Connector Piece
MPN: DA74C-1A · Honeywell
Price on request
Request a quote
DAA2-5025 DAA2 Series Digital Audio AmplifierAvailable on requestDAA2-5025 DAA2 Series Digital Audio Amplifier
MPN: DAA2-5025 · Honeywell
Price on request
Request a quote
DABC Dual Action CoverAvailable on requestDABC Dual Action Cover
MPN: DABC · Honeywell
Price on request
Request a quote
DACT-UD2 DACT-UD2 Digital Alarm TransmitterAvailable on requestDACT-UD2 DACT-UD2 Digital Alarm Transmitter
MPN: DACT-UD2 · Honeywell
Price on request
Request a quote
DAGS3000 Selective General Alarm DiffuserAvailable on requestDAGS3000 Selective General Alarm Diffuser
MPN: DAGS3000 · Honeywell
Price on request
Request a quote
DALI EXPANDER Bus DevicesAvailable on requestDALI EXPANDER Bus Devices
MPN: DALI EXPANDER · Honeywell
Price on request
Request a quote
DALI PS2 DALI64 PSUAvailable on requestDALI PS2 DALI64 PSU
MPN: DALI PS2 · Honeywell
Price on request
Request a quote