Honeywell – AR001-R00A 301IRF Refrigerant Gas Detector
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Honeywell Fire Detectors & Manual Call Points |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can AR001-R00A be shipped?
AR001-R00A is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up AR001-R00A in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for AR001-R00A and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for AR001-R00A, subject to availability and destination.
Install Honeywell 301IRF sensor at low levels in chiller room for reliable detection of a variety of refrigerant gasses. Requires installation with a 301EM-20 controller.
Product Overview:
Discreet design and rugged ABS-Polycarbonate housing for the 301IRFS set the standard for “at the source” gas detection in a chiller room. Mount directly to the chiller pad or low on the wall in close proximity to achieve early notifications in the event of a refrigerant leak.
ASHRAE No 15-2001 Mechanical Standard and B-52 Code Compliance. The ASHRAE and B-52 security standards have been established to minimize risk and protect the safety of mechanical room personnel and the environment at large. Honeywell’s 301IRF, together with the 301EM mechanical room controller, provides a complete solution that meets and even exceeds these rigorous standards. The 301EM can be configured to offer automatic fan, horn and strobe activation in addition to manual fan activation when the 301IRF detects a refrigerant.
Additional Features and Benefits:
User Friendly:
State-of-the-art infrared sensor technology
LED indicator
Low-profile and rugged construction for low mounting in chiller/mechanical roomEconomical Solution:
Cost-effective answer for installation in areas where refrigeration gas hazards may be presentDetectable Gasses:
R11, R22, R123, R125, R134A, R404A, R407C, R410A, R448A, R449A, R507A, R513A, R514A, R4310, 1233ZD, 1234ZE.Features & Benefits:
Infrared sensing technology responds promptly
Low-profile design suited for mounting directly to chiller pad or low on nearby wall
Low maintenanceQuick Specs:
Power requirement operates on 12 VDC power only
Dimensions 4” H x 11” W x 2.5” D (10.2 x 28 x 6.3 m)
Weight 2.33 lbs (0.603 kg)
Honeywell AR001-R00A — An infrared refrigerant gas detector used with the 301EM-20. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Active |
| Brand line | Honeywell |
Overview
| Brand | Honeywell |
Features
| Sub-Category | Gas Detection Sensors & Transmitters |
| Alarm Type | Audible and Visual |
| Alarm Included | Yes |
| Display Included | No |
| Features & Benefits | Infrared Sensing Technology Responds Promptly, Low Maintenance, Low-Profile Design Suited for Mounting Directly to Chiller Pad or Low on Nearby Wall |
| Relay Included | Yes |
| Sampling Pump Included | No |
| Sensors Included | 1 |
| Warnings & Restrictions | Black Engraved Letters on White Bond, Signs Should be 12 to 16 in (30 to 40 cm) Square, They must Designate and Identify the Meaning of All System Status from Visual and Audible Alarm Devices, They should be Located Close to Every Warning Device |
| Visual Indicators | Failure Indication: LED will Remain ON, Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20, Normal Operation: LED Blinks According to the Sensor Addresses on the 301EM-20 |
| Measuring Principle | 3-Electrode Electrochemical |
Dimensions & Weight
| Weight range | 2.33 lbs |
| Overall Width | 11 in |
| Overall Height | 4 in |
| Overall Depth | 2.5 in |
Technical Specifications
| Sensor Range | 0 to 1000 ppm |
| Humidity Range | 0 to 95% RH (Non-Condensing) |
| Number of Analog Outputs | 1 |
| Sensing Method | Infrared |
| Operating Life | 5 |
| Accuracy | ± 40 ppm @500 ppm |
| Number of Relay Outputs | 4 |
| Mounting | Rack, Wall |
| Warm Up Time | 15 min |
Operating Characteristics
| Minimum Temperature | 0°C |
Battery & Charging
| Batteries Required | No |
| Batteries Included | No |
Material Specifications
| Material | ABS Polycarbonate |
Applications & Compatibility
| For Use With | 301EM-20 |
Electrical Specifications
| Maximum Analog Input Supply Voltage | 12 |
| Maximum Analog Input Supply Current | 2 A |
Others
| Industry | Energy |
Ordering codes
| Part numbers on this product page | AR001-R00A, AT404-J00, AT704-400M, AV707-400, B001-L5, B006-L5, B009-L5, B017-L5, B020-L5, B028-L5, B030-L5, B031-L5, B100-L5, B100-MRU-L5, B120-L5, B401-L5, B402-L5, B505-L5, S301-IRF-1233ZD, S301-IRF-1233ZD-NL, S301-IRF-1234ZE, S301-IRF-1234ZE-NL, S301-IRF-R11, S301-IRF-R11-8X, S301-IRF-R11-K, S301-IRF-R11-NL, S301-IRF-R123, S301-IRF-R123-8X, S301-IRF-R123-K, S301-IRF-R123-NL, S301-IRF-R1233ZD-K, S301-IRF-R1234ZE-K, S301-IRF-R125, S301-IRF-R125-8X, S301-IRF-R125-K, S301-IRF-R134A-NL, S301-IRF-R22, S301-IRF-R22-8X, S301-IRF-R22-K, S301-IRF-R22-NL |