Honeywell 31074330-501

Electrode TIP Slotted

MPN
31074330-501
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Honeywell parts? We buy surplus →

What is the Honeywell 31074330-501?

Part of Honeywell's HB and HBD Series Ruggedized Electrodes range. Designed for applications involving high temperature, high pressure and harsh chemical conditions, Honeywell’s HB Series of pH electrode mountings provide a solution for all pH needs, along with Meridian glass pH electrodes and Durafet® non-glass electrodes. The electrode assembly in the pH electrode mountings is constructed with rugged materials such as CPVC, Polypropylene and Kynar.

HBD Series pH electrodes combine the superior reliability and stability of the Durafet sensor with the unique, long lasting reference electrode design. This combination results in a pH solution for the most demanding and harsh process environments.​

What Is It?

​The HB and HBD Series use a unique reference technology that includes a host of advanced features that deliver long life and facilitate accurate and cost-effective measurement. The HBD Series incorporates the non-glass Durafet sensor with a unique reference design. The non-glass sensor is virtually unbreakable, lowering replacement electrode inventory costs. It is also more stable over time, reducing calibration frequency and time.

Constructed with rugged materials such as CPVC (HB only), Polypropylene (HBD only) and Kynar, the electrode assembly can be customized entirely to fit a wide range of process needs. Ideal for high temperature and high pressure applications, both the series can be used in both low and high pH conditions. The electrodes are compatible with most industrial transmitters and analyzers, and can be retrofitted to existing pH instrumentation.

How Does It Work?

​The reference technology prevents poisoning, internal plugging and internal leakage. Complete filling of reference body allows extreme temperature and pressure tolerance.

The HB and HBD Series is available in three designs which use different threaded connections for easy installation depending on the process. For in-line or submerged operations, the 546 uses a ¾-inch MNPT threaded nose, while the 551 used as a quick change sensor includes a 1-inch MNPT threaded adapter for installation. The 551 sensor comes with a nut-loc retainer for quick removal and replacement.

The 547, used with specified ball valve assemblies, is available with a 1-inch MNPT Wrench-tite, or 1-1/4-inch MNPT Hand-tite compression fittings.

What Problems Does It Solve?

​Honeywell’s HB and HBD Series of pH electrode mountings series is the preferred choice for applications involving high temperature, high pressure and aggressive chemical compositions. Rugged materials such as CPVC, Polypropylene and Kynar make these electrodes strong and virtually unbreakable. These electrodes are easy to clean and can be changed quickly. Designed to last long, they provide significant cost savings through the need for fewer replacement electrodes.

The HBD Series is best suited for the harshest conditions, providing long life as compared to traditional pH electrodes.

Honeywell 31074330-501 — Electrode TIP Slotted (HB and HBD Series Ruggedized Electrodes). PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.

Specifications

Product

LifecycleActive
DescriptionElectrode TIP Slotted
Product seriesHB and HBD Series Ruggedized Electrodes

31074330-501: frequently asked questions

When can 31074330-501 be shipped?

31074330-501 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 31074330-501 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 31074330-501 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 31074330-501, subject to availability and destination.

More Honeywell parts

Honeywell 31063261-501 – Meredian SST Support Tube
Honeywell
31063261-501

Meredian SST Support Tube

Honeywell 310668/U – High Temperature Diaphragm - SIlicone
Honeywell
310668/U

High Temperature Diaphragm - SIlicone

Honeywell 31072925 – Gauge Hydrogen
Honeywell
31072925

Gauge Hydrogen

Honeywell 310808 – SPACER
Honeywell
310808

SPACER

Honeywell 31074330-501Price and lead time confirmed within 1 business day
Request a Quote