Honeywell – 033-1102-002 RAEGuard 2 PID Gas Detector
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Honeywell Fire Detectors & Manual Call Points |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 033-1102-002 be shipped?
033-1102-002 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 033-1102-002 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 033-1102-002 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 033-1102-002, subject to availability and destination.
RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs)
Product Overview:
RAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a broad range of volatile organic compounds (VOCs). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output and RS-485 Modbus digital signal output. Calibration and maintenance have been greatly simplified as the digital PID module can be easily removed in hazardous locations for calibration or maintenance.
The RAEGuard 2 PID has a graphic display and local sound alarm and LED light status indicator. In addition, Low, High, and Fault relays can be configured to trigger external alarms or process controls. A magnetic key interface enables the detector to be calibrated and operational parameters adjusted with the explosion-proof enclosure in place.
Features & Benefits:
Faster response time - Thanks to the sample flow-through design
Reduce maintenance cost - Easy to remove sensor module in hazardous locations without using of tools
No false alarms - Large UV lamp and better sealing allows greater sensitivity, faster speed of response and better resolution
Quick Specs:
Digital Smart Sensor Technology
Detection range 0.01 to 100 ppm, 0.1 to 1000 ppm, or 1 to 1000 ppm
Operates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output
Graphic display and LED light status indicator for fault and alarm conditions
Fire and Gas Consultancy Services
Even the best products deserve expert maintenance!
Elevate your gas detectors’ potential with Honeywell's expert maintenance services! Maximize uptime, eliminate costs, and ensure on-time, on-budget project completion.
Explore our fixed, portable, and high-tech support services now!
Honeywell RAE 033-1102-002 — A fixed gas detector using photoionization (PID) that monitors a broad range of volatile organic compounds. PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Active |
| Brand line | RAE |
Overview
| Brand | RAE |
| Warranty | 1 Year for the Pump, 2 Years for the Housing and Electronics |
Features
| Sub-Category | Gas Detection Sensors & Transmitters, Gas Detection Sensors & Transmitters |
| Alarm Included | Yes |
| Display Type | LCD |
| Display Included | Yes |
| Features & Benefits | Accurate Readings, Continuous VOC Monitoring in Hazardous and Non-Hazardous Locations, Easy to Remove Sensor Module in Hazardous Locations without Use of Tools, Fast Speed of Response Provides Earliest Warning, Reduced Life Cost |
| Filter Included | Yes |
| Sampling Pump Included | Yes |
| Wireless Technology | Mesh |
| Replacement Parts | DigiPID Sensor Module, Lamp |
| Vibration | Meets or Exceeds MIL Spec 810C Method 514.2, Curve AW12 |
Dimensions & Weight
| Weight range | 3.5 Kg |
| Inlet Connector Thread | 0.75 in |
| Dimension | L: 10.1 in W: 7.9 in H: 4.2 in |
Technical Specifications
| Humidity Range | 0 to 95% RH (Non-Condensing) |
| Number of Analog Outputs | 1 |
| Analog Outputs | 4 to 20 mA |
| Analog Output Connection | 3-Wire |
| Calibration Procedures | Zero and Span Low, Zero, Span Low and Span High |
| Calibration Points | 2 |
| Calibration Gas | Isobutylene |
| Calibration | Automatic, Fresh Air |
| Display Viewing Area | 128 x 64 |
| Filter Type | Coalescing |
| Filter Required | Yes |
| Number of Digital Communication Ports | 1 |
| Relay Rated Load | 30 VDC, 2A |
| Relay Circuit Resting Configuration | NO, NC |
| Sampling Pump Location | Internal |
| Sensor Mechanism | PID |
| Sensing Method | PID |
| Operating Life | 2 |
| Number of Signal Outputs | 1 |
| Number of Relay Outputs | 3 |
| Number of Contacts | 3 |
| Mounting | Wall |
| Maximum Pressure | 110 kPa |
| Drift | 10 |
| Default Relay Activation | Low, High, Fault |
| Spectral Sensitivity | Infrared: 0.7 to 3.5 Micrometers (SS4-A and SS4-AS Only), Ultraviolet: 185 to 260 Nanometers Wide Band, Visible: 400 to 700 Nanometers (SS4-A and SS4-AS only) |
| Signal Output | 3-Wire Signal Output |
| Sensitivity | Adjustable Between 60 ft, 45 ft, 30 ft, and 15 ft to a 1 sq.ft Gasoline Fire |
| Mounting Thread | 3/4 in NPT |
| Field of View | 120° Cone of Vision |
Operating Characteristics
| Minimum Temperature | -20°C |
Electrical Specifications
| Analog Output Signal Current | 4 to 20 mA |
| Maximum Operating Current | 210 mA |
| Maximum Analog Input Supply Current | 110 |
| Analog Output Signal Voltage | 0.5 to 2.5 V |
| Power Requirement | 24 VDC |
| Power Consumption | < 5W |
| Operating Voltage | 10 to 28 VDC |
Material Specifications
| Material | 316 Stainless Steel |
| Filter Insert Material | PTFE |
Standards & Certifications
| Ingress Protection | IP65 |
Applications & Compatibility
| Application | Acetone, Xylene, Phenol in Medical, Pathology, Histology Lab, Air Quality, Ammonia in Industry, Benzene in Refinery Analyser Shelters, Heat Transfer Fluids, Methyl Ethyl Ketone in Paint Spray Booths, Solvent and Chemicals Storage, Toluene in Printing, Toluene or Ammonia in Semi-Conductor Plants, Vinyl Chloride in Chemical Manufacturing |
Others
| Industry | Energy |
Ordering codes
| Part numbers on this product page | 033-1102-002, 033-1217-100, 033-2066-000, 033-3003-100, 033-3032-000, 033-3033-000, 033-3034-000, 033-3035-000, 036-0005-000, 050-0000-003, 050-0000-005, 050-0061-001, 081-0017-000, 081-0018-000, 081-0018-C00, 081-018-C00, 3005-9595-004, 3006-6744-001, 411-0024-026, 430-0009-025, 430-0314-000, 430-B076-060, 430-B082-0H0, 430-B083-0H0, 490-0011-000, 490-0011-005, 490-0130-000, 490-0163-000, 490-0164-010, 490-0804-000, 490-3010-000, 490-3039-000, 600-0001-000, 600-0002-000, 600-0002-001, 600-0024-000, 600-0051-000, 600-0052-000, 600-0053-000, 600-0061-000 |
More Honeywell parts
Available on request032238.17 IDENTLOC Slimline glass breakage sensor
Available on request032245.17 Locking sensor with magnetic contact
Available on request032268 Glue Gauge For Passive Glass Breakage Sensor
Available on request032272.17 Mini Glass Breakage Sensor
Available on request033-2004-000 Splash Guard for stainless steel mounting bracket