B&R X90AISG0.02-00
I/O module, 2 full-bridge strain gauge inputs
- MPN
- X90AISG0.02-00
- Category
- Analog inputs
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
- 100% positive eBay feedback
What is the B&R X90AISG0.02-00?
9 to 32 VDC
2 full-bridge strain gauge inputs
Data output rate configurable from 2.5 Hz to 7.5 kHz
Special operating modes (synchronous mode and multisampling)
Configurable filter level
This module is equipped with 2 inputs for evaluating full-bridge strain gauges and works with 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature. Communication to the mainboard is made possible via X2X Link.
Specifications
Short description
| I/O module | 2 full-bridge strain gauge inputs |
General information
| Certifications – UN ECE-R10 | Yes |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| B&R ID code | 0xF79D |
| Status indicators | - |
Multi-function inputs
| Multifunction analog inputs (MF-AI) – Quantity | 2 |
| Multifunction analog inputs (MF-AI) – Functions | Analog input, 24-bit digital converter resolution |
Full-bridge strain gauge
| Input filter – Cutoff frequency | 5 kHz |
| Input filter – Order | 3 |
| Input filter – Slope | 60 dB |
| Output of digital value – Broken bridge supply line | Value approaching 0 |
| Output of digital value – Broken sensor line | Value approaching ±end value (status bit "Line monitoring" is set in register "Module status") |
| Output of digital value – Valid range of values | 0xFF800001 to 0x007FFFFF (-8,388,607 to 8,388,607) |
| Strain gauge supply – Voltage | 5.5 VDC / Max. 65 mA |
| Strain gauge supply – Short-circuit and overload-proof | Yes |
| Strain gauge supply – Voltage drop for short-circuit protection | Max. 0.2 VDC at 65 mA and 25°C |
| Quantization – 2 mV/V | 336 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 4 mV/V | 671 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 8 mV/V | 1.343 μV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 16 mV/V | 2.686 μV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 32 mV/V | 5.371 μV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 64 mV/V | 10.74 μV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 128 mV/V | 21.48 μV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 256 mV/V | 42.97 μV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 2 mV/V | 1.31 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 4 mV/V | 2.62 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 8 mV/V | 5.25 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 16 mV/V | 10.49 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 32 mV/V | 20.98 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 64 mV/V | 41.96 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 128 mV/V | 83.92 nV (note: Quantization depends on the strain gauge factor.) |
| Quantization – 256 mV/V | 167.85 nV (note: Quantization depends on the strain gauge factor.) |
| Strain gauge factor | 2 to 256 mV/V, configurable using software |
| Connection | 4- or 6-wire connectionsConnection examples")."> (note: With 6-wire connections, line compensation does not function (see section) |
| Input type | Differential, used to evaluate a full-bridge strain gauge |
| Digital converter resolution | 24-bit |
| Conversion time | Depends on the configured data output rate |
| Data output rate | 2.5 to 7,500 samples per second, configurable using software (f DATA ) |
| ADC filter characteristics | Sigma-delta, see section "Filter characteristics of the sigma-delta A/D converter" |
| Operating range / Measurement sensor | 85 to 5,000 Ω |
| Influence of cable length | See section "Calculation example", sensor cable length: Max. 30 m |
| Input protection | RC protection |
| Common-mode range | 0 to 3 VDC; Permissible input voltage range (with regard to the electric potential strain gauge GND) on inputs "Input +" and "Input -" |
| Conversion procedure | Sigma-delta |
| Max. gain drift | 12 ppm/°C (note: Based on the current measured value.) |
| Max. offset drift | 2 ppm/°C (note: Based on the entire measurement range.) |
| Nonlinearity | <10 ppm (note: Based on the entire measurement range.) |
Operating conditions
| Mounting orientation – Any | Yes |
| Chemical resistance | Not guaranteedStandards and certifications - Requirements for vehicles - Chemical resistance" in the X90 user's manual."> (note: Chemical resistance per ISO 15003 has not been tested. See section) |
| Degree of protection per EN 60529 | Up to IP66 (note: Depends on the mainboard. For additional details, see the data sheet for the mainboard.) |
Ambient conditions
| Temperature – Horizontal mounting orientation | -40 to 85°C housing surface (note: Depends on the mainboard. For additional details, see the data sheet for the mainboard.) |
| Temperature – Vertical mounting orientation | -40 to 85°C housing surface (note: Depends on the mainboard. For additional details, see the data sheet for the mainboard.) |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 100%, condensing |
| Relative humidity – Storage | 5 to 100%, condensing |
| Relative humidity – Transport | 5 to 100%, condensing |
| Shock – Operation | For shock test 50 g, 11 ms analog values out of toleranceX90 user's manual - International and national certifications - Vehicle requirements - Mechanical conditions - Shock"."> (note: Shock (50 g, 11 ms) testing performed per EN 60068-2-27 type I per ISO 15003 level 3. See) |
Mechanical properties
| Dimensions – Width | 47 mm |
| Dimensions – Length | 95 mm |
| Torque for connections – M12 | 0.6 Nm |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
X90AISG0.02-00: frequently asked questions
When can X90AISG0.02-00 be shipped?
X90AISG0.02-00 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X90AISG0.02-00 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X90AISG0.02-00 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X90AISG0.02-00, subject to availability and destination.
More B&R parts