Specifications
Short description
| Potential distributor module with supply | 6x 24 VDC on the terminals, 6x ground on the terminals |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Fuse monitoring | Yes, using LED status indicator and software |
| Power consumptionMechanical and electrical configuration" in the X20 system user's manual."> – Bus | 0.12 W (note: The specified values are maximum values. For examples of the exact calculation, see section) |
| Power consumptionMechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 1.15 W (note: The specified values are maximum values. For examples of the exact calculation, see section) |
| Power consumptionMechanical and electrical configuration" in the X20 system user's manual."> – External I/O | 1.15 W (note: The specified values are maximum values. For examples of the exact calculation, see section) |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| B&R ID code | 0xE23B |
| Status indicators | Operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
Input power supply with feed
| Nominal input voltage | 24 VDC -15% / +20% external, ground external |
| Input current | Max. 6 A |
| Fuse | Integrated 6.3 A, slow-blow, can be replaced |
| Behavior on short circuit | No protection available ; Use an external fuse. |
| Reverse polarity protection | No |
Output I/O power supply
| Behavior on short circuit – On 24 VDC power supply | Integrated fuse |
| Behavior on short circuit – On GND power supply | No protection available |
| Nominal output voltage | 24 VDC, ground |
| Permissible contact load | 6 A |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | Up to 100%, condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately. ; Order 1x bus module X20cBM01 or X20cBM11 separately. |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20cBM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. |
| X20cBM01 | Bus modules — Basis for all power supply modules; For creating potential groups; The internal I/O power supply is interrupted to the left. |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (9)
- 2226379 CSA Certificate of Compliance X20 X67
- ABS Certificate of Product Design Assessment - X20 IO Series
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- TAA00000BJ DNV Type Approval Certificate X20
X20cPD2113: frequently asked questions
When can X20cPD2113 be shipped?
X20cPD2113 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20cPD2113 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20cPD2113 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20cPD2113, subject to availability and destination.
More B&R parts