B&R X20cDS1119
I/O module, 3 digital 5 V (symmetrical) channels…
- MPN
- X20cDS1119
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the B&R X20cDS1119?
3 digital 5 V channels, configurable as inputs or outputs
2 digital 24 V input channels
1 universal counter pair (2 event counters, AB counters or up/down counters)
Linear motion generator (A/B, direction/frequency) with one reference pulse
SSI absolute encoder
NetTime timestamp: Input data, target position, position change, edge change, counter change
Specifications
Short description
| I/O module | 3 digital 5 V (symmetrical) channels configurable as inputs or outputs, 2 digital 24 V (asymmetrical) input channels, 1 universal counter pair (2 event counters, AB counter or up/down counter), linear motion generator (A/B, direction/frequency) with 1 reference pulse, SSI absolute encoder, relative or absolute moments of input edges with microsecond resolution, time-triggered I/O, I/O oversampling |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – Inputs/Outputs | Yes, using LED status indicator |
| Power consumption – Bus | 0.01 W |
| Power consumption – Internal I/O | 1.5 W |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – HazLoc | cCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5 |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| B&R ID code | 0xE20D |
| Status indicators | I/O function per channel, operating state, module status |
| Additional power dissipation caused by actuators (resistive) [W] | - |
| Type of signal lines | Shielded lines must be used for all signal lines. |
Linear motion generator
| Quantity | 1 |
| Encoder outputs | 5 V, symmetrical (A/B, direction/frequency) |
| Counter size | 16/32-bit |
SSI absolute encoder
| Encoder power supply – 5 VDC | ±5%, module-internal, max. 300 mA |
| Encoder power supply – 24 VDC | Module-internal, max. 300 mA |
| Quantity | 1 |
| Counter size | Up to 32-bit depending on encoder |
| Max. transfer rate | 1 Mbit/s |
| Encoder signal | 5 V, symmetrical |
Digital inputs 5 VDC
| Input filter – Hardware | ≤200 ns |
| Input filter – Software | - |
| Quantity | Up to 3, configuration as input or output using software |
| Nominal voltage | 5 VDC differential signal, EiA RS485 standard |
| Input characteristics per EN 61131-2 | Type 1 |
| Input frequency | 600 kHz |
| Common-mode range | -7 V ≤ V CM ≤ +12 V |
| Insulation voltage between encoder and bus | 500 V eff |
| Overload characteristics of encoder power supply | Short-circuit proof, overload-proof |
| Additional functions | SSI absolute encoder, universal counter pair |
Digital inputs 24 VDC
| Input filter – Hardware | ≤2 µs |
| Input filter – Software | - |
| Switching threshold – Low | <5 VDC |
| Switching threshold – High | >15 VDC |
| Quantity | 2 |
| Nominal voltage | 24 VDC |
| Input characteristics per EN 61131-2 | Type 1 |
| Input circuit | Sink |
| Input voltage | 24 VDC -15% / +20% |
| Input current at 24 VDC | Approx. 3.4 mA |
| Input resistance | Approx. 7.19 kΩ |
| Input frequency | 100 kHz |
| Insulation voltage between channel and bus | 500 V eff |
| Additional functions | Latch function for universal counter pair |
Universal counter pair
| Evaluation – AB counter | 4xCounter"."> (note: Problems may occur during evaluation due to the system at an input frequency greater than 500 kHz. For additional information, see section) |
| Evaluation – Event counters | 2x |
| Evaluation – Up/Down counter | 2x |
| Encoder power supply – 5 VDC | ±5%, module-internal, max. 300 mA |
| Encoder power supply – 24 VDC | Module-internal, max. 300 mA |
| Quantity | 1 |
| Operating modes | 2x event counter, up/down counter, AB counter |
| Encoder inputs | 5 V, symmetrical |
| Counter size | 16/32-bit |
| Input frequency | Max. 600 kHz |
Digital outputs 5 VDC
| Quantity | Up to 3, configuration as input or output using software |
| Type | 5 VDC differential signal, EiA RS485 standard |
| Output circuit | Sink and/or source |
| Output protection | Short-circuit protection |
| Variant | Push/Pull/Push-Pull |
| Nominal voltage | 5 VDC |
| Output current | Max. 65 mA |
| Diagnostic status | Output is readable. |
| Switching frequency | Max. 500 kHz |
| Insulation voltage between channel and bus | 500 V eff |
| Switching voltage | 5 VDC differential signal, EiA RS485 standard |
| Additional functions | SSI absolute encoder, linear motion generator |
Electrical properties
| Electrical isolation | Channel isolated from bus; Channel not isolated from channel |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | - |
| Temperature – Starting temperature | Yes, -40°C |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | Up to 100%, condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x bus module X20cBM11 separately. |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20cBM11 | Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (12)
- 2226379 CSA Certificate of Compliance X20 X67
- ABS Certificate of Product Design Assessment - X20 IO Series
- E115267 UL Certificate of Compliance X20
- EU Data Act - X20 IO - Connected Product Information Notice
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- FTZU 09 ATEX 0083X
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- TAA00000BJ DNV Type Approval Certificate X20
- UK Declaration PLC X20
X20cDS1119: frequently asked questions
When can X20cDS1119 be shipped?
X20cDS1119 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20cDS1119 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20cDS1119 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20cDS1119, subject to availability and destination.
More B&R parts