B&R 8I86T404500.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 45 kW

MPN
8I86T404500.00-000
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare B&R parts? We buy surplus →

What is the B&R 8I86T404500.00-000?

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 45 kW, EMC filter and brake chopper.Order number - ACOPOSinverter P86:8I86T404500.0P-200: Inverter with POWERLINK communication card

Specifications

General information

Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ULcULus E225616; Power conversion equipment

Motor power

Specified on nameplate45 kW (60 HP)

Mains connection

Mains current – At 380 VAC81.4 A (note: Additional restrictions result from parameter SVL.)
Mains current – At 480 VAC71.8 A (note: Additional restrictions result from parameter SVL.)
Power dissipation – External cooling776 W
Power dissipation – Natural cooling143 W
Mains input voltage3x 380 VAC -15% to 480 VAC +10%
Frequency50 to 60 Hz ±5%
Apparent power (at 480 VAC)59.7 kVA
Max. assumed short-circuit current (Isc); (short-circuit current at connection point)50 kA
Inrush currentMax. 176 A
Integrated EMC filterYes

Line-conducted and radiated emissions

With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network)-
With integrated filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system)100 m
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C1 environment 1 (public power network)-
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C2 environment 1 (public power network)C2 level at 4 kHz with 150 m cable
With add-on filter – Motor cable length per IEC/EN 61800-3 ; Cat. C3 environment 2 (industrial power system)C3 level at 4 kHz with 300 m cable
With add-on filter8I0FT160.200-1

Motor connection

Derating of continuous output current depending on ambient temperature – At nominal clock frequency (4 kHz or 2.5 kHz with higher inverter power)No derating
Derating of continuous output current depending on ambient temperature – Other clock frequenciesThe derating curves are included in the installation instructions, which can be downloaded from www.br-automation.com.
Derating of continuous output current depending on installation elevation – Starting at 1000 m above sea level1%, per 100 m
Clock frequency – Min.2 kHz
Clock frequency – Max.8 kHz
Max. motor cable length – Shielded cable150 m
Max. motor cable length – Non-shielded cable300 m
Motor control profiles – Induction motorSensorless vector control: ; 1. Voltage controlled with constant torque; → Default mode; 2. Voltage controlled with variable torque; → Energy-saving mode, e.g. for fans and pumps; Vector control with encoder: ; 1. Current-controlled with constant torque; → Default mode; Sensorless slip control: ; 1. With V/f characteristic curve for constant torque; → Default mode; 2. With V/f characteristic curve for constant torque (up to 6 f ranges); → Mode for individual special applications; 3. With V/f characteristic curve for quadratically increasing torque; → Energy-saving mode, e.g. for fans and pumps
Motor control profiles – Synchronous motorSensorless vector control: ; 1. Voltage controlled with constant torque; → Default mode; Vector control with encoder: ; 1. Current-controlled with constant torque; → Default mode
Nominal output current88 A
Max. transient current for 60 s132 A
Max. transient current for 2 s132 A
Output frequency range0.1 to 500 Hz
Nominal clock frequency2.5 kHz
Main protective functions of inverterThermal protection against power stage overheating; Protection against short circuits between motor phases, overcurrent between output phases and ground, overvoltages on the DC bus, exceeding the speed limit. Safety function for: Overvoltage and undervoltage of the mains supply, mains phase failure with 3-phase power supply

Brake chopper

Integrated dynamic brake transistorsYes
Min. resistance value (external)2.5 Ω

24 VDC power supply

Input voltage24 VDC (min. 20.4 VDC, max. 27 VDC)
CurrentMax. 0.8 A

Available internal power supplies

Output voltage 24 VDC – Max. output current at 24 VDCMax. 200 mA
Output voltage 10 VDC – Max. output current at 10 VDCMax. 10 mA
Output voltage 24 VDC24 VDC (min. 20.4 VDC, max. 27 VDC)
Output voltage 10 VDC10.5 VDC ±5%

Interfaces

POWERLINK – TypeType 3Communication / POWERLINK / General information / Hardware - CN" in Automation Help."> (note: For additional information, see section)

Digital inputs

Switching threshold – LowSource: <0.5 V; Sink: >16 V
Switching threshold – HighSource: >11 V ; Sink: <10 V
Electrical isolation – Input - ACOPOSinverterYes
Electrical isolation – Input - InputNo
Quantity8
Nominal voltage24 VDC (max. 30 VDC)
Input circuitSource or sink
Sampling time2 ms ±0.5 ms
Input impedance4.4 kΩ

Safe input - STO (Safe Torque Off)

Switching threshold – Low<5 V
Switching threshold – High>11 V
Electrical isolation – Input - ACOPOSinverterYes
Electrical isolation – Input - InputNo
Quantity2
Nominal voltage24 VDC (max. 30 VDC)
Input impedance2.2 kΩ
Input circuitSource

Event counters

Switching threshold – Low<0.6 V
Switching threshold – High>2.5 V
Quantity2
Nominal voltage24 VDC (max. 30 VDC)
Input frequency0 to 30 kHz
Input circuitSource
Sampling time5 ms ±1 ms

Analog inputs

Electrical isolation – Input - InputNo
Electrical isolation – Input - ACOPOSinverterYes
Input – Voltage0 to 10 VDC
Input – CurrentAI1: 0 to 20 mA
Input impedance – Voltage31.5 kΩ
Input impedance – Current250 Ω
Quantity3
Nonlinearity±0.15%
Basic accuracy±0.6% with temperature fluctuation of 60°C
Resolution12-bit
Sampling time1 ms ±1 ms

Digital outputs

Quantity1
Nominal voltage24 VDC -15%/+20%
Max. voltage30 VDC
Output circuitSource or sink
Max. current100 mA (note: Programmable as event counter: 20 mA.)

Relay outputs

Execution – Relay 11 changeover contact
Execution – Relay 21 normally open contact
Execution – Relay 31 normally open contact
Electrical isolation – Output - ACOPOSinverterYes
Electrical isolation – Output - OutputNo
Quantity3
Nominal voltage30 VDC / 250 VAC
Switching current rangeMin. switching current: 5 mA at 24 VDC; Max. switching current:; R1: At cos φ = 1: Max. 3 A / At cos φ = 0.4: Max. 2 A; R2 and R3: At cos φ = 1: Max. 5 A / At cos φ = 0.4: Max. 2 A
Response time (max.)5 ms ±0.5 ms

Analog outputs

Electrical isolation – Output - ACOPOSinverterYes
Electrical isolation – Output - OutputNo
Max. load impedance – Voltage470 Ω
Max. load impedance – Current500 Ω
Quantity2
Output0 to 10 VDC or 0 to 20 mA
Nonlinearity±0.2%
Basic accuracy±1% with temperature fluctuation of 60°C
Sampling time5 ms ±1 ms
Resolution10-bit

Electrical properties

Energy efficiency (IE classification) – Power dissipation relative to continuous apparent powerIE2 (10, 25): 0.5% (3x 380 VAC), 0.4% (3x 480 VAC); IE2 (50, 25): 0.5% (3x 380 VAC), 0.4% (3x 480 VAC); IE2 (10, 50): 0.7% (3x 380 VAC), 0.6% (3x 480 VAC); IE2 (50, 50): 0.7% (3x 380 VAC), 0.6% (3x 480 VAC); IE2 (90, 50): 0.8% (3x 380 VAC), 0.6% (3x 480 VAC); IE2 (10, 100): 1.3% (3x 380 VAC), 1.1% (3x 480 VAC); IE2 (50, 100): 1.3% (3x 380 VAC), 1% (3x 480 VAC); IE2 (90, 100): 1.5% (3x 380 VAC), 1.2% (3x 480 VAC)
Energy efficiency (IE classification) – Nominal losses in standby mode32 W

Operating conditions

Degree of protection per EN 61800-5-1IP20
Degree of protection per EN 60529IP20
Relative humidity per IEC 60068-2-35 to 95%, non-condensing
Maximum installation elevation≤1000 m without derating; 1000 to 4800 m with Derating
Max. pollution degree per IEC/EN 61800-5-12 (non-conductive pollution)
Ambient conditions per IEC 60721-3-3Class 3C3 and 3S3
Operating positionVertical mounting orientation ±10°

Ambient conditions

Temperature – Operation-15 to 50°C without derating; 50 to 60°C with derating
Temperature – Storage-40 to 70°C
Max. vibration resistance1 g n 13 to 200 Hz EN/IEC 60068-2-6 ; 1.5 mm peak to peak 2 to 13 Hz EN/IEC 60068-2-6
Max. shock resistance15 g n (duration = 11 ms) per EN/IEC 60721-3-3 class 3M3

Mechanical properties

Dimensions – Width271 mm
Dimensions – Height908 mm
Dimensions – Depth309 mm
Weight56.4 kg

Accessories

Optional accessories (15)
8I0XD304.310-1Cable and adapters — RJ45 cable, 10 m, for remote use of the display for the ACOPOSinverter.
8I0XD304.305-1Cable and adapters — RJ45 cable, 5 m, for remote use of the display for the ACOPOSinverter.
8I0XD304.303-1Cable and adapters — RJ45 cable, 3 m, for remote use of the display for the ACOPOSinverter.
8I0XD304.301-1Cable and adapters — RJ45 cable, 1 m, for remote use of the display for the ACOPOSinverter.
8I0XC001.003-1Cable and adapters — USB adapter cable, USB to Modbus, for ACOPOSinverter.
8I0XF086.405-1Fans (spare part) — ACOPOSinverter P86 fan kit for size 5, power output class: 45 to 75 kW (60 to 100 HP)
8I0IFENC.403-1Interface modules — ACOPOSinverter P86 encoder interface (HTL), encoder type / signal: AB (push-pull) supply voltages: 12, 15, 24 VDC
8I0IFENC.402-1Interface modules — ACOPOSinverter P86 encoder interface, encoder type / signal: Resolver
8I0IFENC.401-1Interface modules — ACOPOSinverter P86 encoder interface (analog), encoder type / signal: SinCos supply voltages: 5, 12, 24 VDC encoder type / signal: HIPERFAC…
8I0IFENC.400-1Interface modules — ACOPOSinverter P86 encoder interface (digital), encoder type / signal: AB, SSI supply voltages: 5, 12, 24 VDC encoder type / signal: ENDAT…
8I0FT160.200-1Optional EMC filters — ACOPOSinverter additional EMC input filter 3-phase 160 A, supply voltage: 380 to 480 V, 50/60 Hz
8I0BR008.002-1Optional braking resistors — Braking resistor ohmic value: 8 Ω continuous braking power: 3.80 kW degree of protection (IP): IP20
8I0PT086.402-1Optional push through mounting kit — Pass-through mounting kit for P86 size 5, power output class: 45 to 75 kW (60 to 100 HP)
8I0XD086.400-1Plain text display — Plain text display for ACOPOSinverter P86, backlight, navigation key, IP43 protection
8I0FM086.400-1Plain text display — Female-to-female installation kit for ACOPOSinverter plain text display, IP43 protection

8I86T404500.00-000: frequently asked questions

When can 8I86T404500.00-000 be shipped?

8I86T404500.00-000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8I86T404500.00-000 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8I86T404500.00-000 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8I86T404500.00-000, subject to availability and destination.

More B&R parts

B&R 8I86T402200.00-000 – Base device for ACOPOSinverter P86, 3x 380 to 480 V, 22 kW
B&R
8I86T402200.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 22 kW

B&R 8I86T403000.00-000 – Base device for ACOPOSinverter P86, 3x 380 to 480 V, 30 kW
B&R
8I86T403000.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 30 kW

B&R 8I86T403700.00-000 – Base device for ACOPOSinverter P86, 3x 380 to 480 V, 37 kW
B&R
8I86T403700.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 37 kW

B&R 8I86T405500.00-000 – Base device for ACOPOSinverter P86, 3x 380 to 480 V, 55 kW
B&R
8I86T405500.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 55 kW

B&R 8I86T407500.00-000 – Base device for ACOPOSinverter P86, 3x 380 to 480 V, 75 kW
B&R
8I86T407500.00-000

Base device for ACOPOSinverter P86, 3x 380 to 480 V, 75 kW

B&R 8I86T404500.00-000Price and lead time confirmed within 1 business day
Request a Quote