B&R 8CVI155S1HCS0.01-1
ACOPOSremote ACOPOSmulti65 inverter module, 15.5 A, AS
- MPN
- 8CVI155S1HCS0.01-1
- Category
- ACOPOSmulti65 inverter modules
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the B&R 8CVI155S1HCS0.01-1?
ACOPOSremote ACOPOSmulti65 inverter module, 15.5 A, AS, IP65, integrated cold plate, 1x SinCos encoder interface, cold plate mounting
Specifications
General information
| Current-carrying capacity of 15-pin TYCO connector – Power contacts | Max. 20 A at 40°C |
| Support – Dynamic node allocation (DNA) | Yes |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – Functional safety | Yes |
| Certifications – UL | cULus E225616; Power conversion equipment |
| Module type | ACOPOSremote module with integrated cold plate |
| B&R ID code | 0xE9EB |
| Cooling and mounting type | Wall mounting ; Water cooling |
DC bus connection
| Voltage – Nominal | 750 VDC |
| Power dissipation depending on switching frequency – Switching frequency 5 kHz | In preparation |
| Power dissipation depending on switching frequency – Switching frequency 10 kHz | In preparation |
| Power dissipation depending on switching frequency – Switching frequency 20 kHz | In preparation |
| Line length – Maximum | 30 m |
| Continuous power consumption | In preparation (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.) |
| DC bus capacitance | 35 µF |
| Variant | 15-pin male TYCO connector (note: It is important to note that the 15-pin male TYCO connector is designed for max. 20 mating cycles.) |
24 VDC power supply
| Line length – Maximum | 30 m |
| Input voltage | 24 VDC +20% / -25% |
| Input capacitance | In preparation |
| Max. power consumption | 10 W + P 24 V out + P Holding brake + P Trigger (note: The power consumption P 24 V Out corresponds to the portion of the power that is output on the X31 connector on the module.) |
| Variant | 15-pin male TYCO connector (note: It is important to note that the 15-pin male TYCO connector is designed for max. 20 mating cycles.) |
24 VDC output
| Variant – 24 VDC, COM | M8 connector |
| Quantity | 1 |
| Output voltage | Depends on the 24 VDC power supply |
| Continuous current | Max. 8 A (max. 4 A per pin) |
| Fuse protection | Electronic (per pin) |
Motor connection
| Reduction of continuous current depending on switching frequency – Switching frequency 5 kHz | No reduction (note: Valid under the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.) |
| Reduction of continuous current depending on switching frequency – Switching frequency 10 kHz | In preparation (note: Valid under the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.) |
| Reduction of continuous current depending on switching frequency – Switching frequency 20 kHz | In preparation (note: Valid under the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.) |
| Reduction of continuous current depending on installation elevation – Starting at 500 m above sea level | 1.4 A per 1,000 m |
| Protective measures – Overload protection | Yes |
| Protective measures – Short-circuit and ground fault protection | Yes |
| Variant – U, V, W, PE | 8-pin speedtec connector, size 1 |
| Variant – Shield connection | Yes (via connector housing) |
| Max. motor line length depending on switching frequency – Switching frequency 5 kHz | 10 m |
| Max. motor line length depending on switching frequency – Switching frequency 10 kHz | 5 m |
| Max. motor line length depending on switching frequency – Switching frequency 20 kHz | 5 m |
| Quantity | 1 |
| Continuous power per motor connection | 7.5 kW (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.) |
| Continuous current per motor connection | 15.5 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.) |
| Peak current | 40 A |
| Nominal switching frequency | 5 kHz |
| Possible switching frequencies | 5 / 10 / 20 kHz (note: B&R recommends operating the module at its nominal switching frequency. Operating the module at a higher switching frequency for application-specific reasons reduces the continuous current and increases CPU utilization.) |
| Insulation stress of the connected motor per IEC TS 60034-25:2004 | Limit value curve A |
| Max. output frequency | 598 HzPower unit: Limit speed exceeded")."> |
Motor holding brake connection
| Protective measures – Overload and short-circuit protection | Yes |
| Protective measures – Open-circuit monitoring | Yes |
| Protective measures – Undervoltage monitoring | Yes |
| Quantity | 1 |
| Output voltage | 24 VDC +5.8% / -0% (note: During configuration, it is necessary to check if the minimum voltage can be maintained on the holding brake with the intended wiring. For the operating voltage range of the holding brake, see the user documentation for the motor being used.) |
| Continuous current per connection | 1.1 A |
| Max. internal resistance | In preparation |
| Extinction potential | Approx. 30 V |
| Max. extinction energy per switching operation | 1.5 Ws |
| Max. switching frequency | 0.5 Hz |
| Response threshold for open-circuit monitoring | Approx. 0.25 A |
| Response threshold for undervoltage monitoring | 24 VDC +0% / -4% |
Fieldbus
| Type | POWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3) |
| Variant | Internal 3-port hub, 2x male 15-pin TYCO connector, 1x M12 connector |
| Line length | Max. 100 m between two stations (segment length) (note: Limited to 30 m when using hybrid cables.) |
| Transfer rate | 100 Mbit/s |
Encoder inputs
| Electrical isolation – Encoder - ACOPOSremote | No |
| Encoder power supply – Overload-proof | Yes |
| Encoder power supply – Short-circuit proof | Yes |
| Encoder power supply – Output voltage | 5 V ±5% |
| Encoder power supply – Load capacity | 300 mA (note: An additional reserve of 12 mA exists for terminating resistors and limit switch inputs.) |
| Encoder power supply – Sense lines | 2, compensation of max. 2 x 0.7 V |
| Sine/Cosine inputs – Signal transmission | Differential signals, symmetrical |
| Sine/Cosine inputs – Signal frequency (-3 dB) | DC up to 300 kHz |
| Sine/Cosine inputs – Signal frequency (-5 dB) | DC up to 400 kHz |
| Sine/Cosine inputs – Differential voltage | 0.5 to 1.25 V ss |
| Sine/Cosine inputs – Common-mode voltage | Max. ±7 V |
| Sine/Cosine inputs – Terminating resistor | 120 Ω |
| Sine/Cosine inputs – ADC resolution | 12-bit |
| Reference input – Signal transmission | Differential signal, symmetrical |
| Reference input – Differential voltage for low | ≤-0.2 V |
| Reference input – Differential voltage for high | ≥0.2 V |
| Reference input – Common-mode voltage | Max. ±7 V |
| Reference input – Terminating resistor | 120 Ω |
| Position – Resolution @ 1 V SS | Number of encoder lines * 5700 (note: This value does not correspond to the encoder resolution that must be configured in Automation Studio (16384 * number of encoder lines).) |
| Position – Accuracy | - (note: Limited by the encoder in practice.) |
| Position – Noise | - (note: Limited by the encoder in practice.) |
| Limit switch inputs – Input - ACOPOSremote | No (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Input - Input | No (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Minimum | -12 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Nominal | 5 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Maximum | 20 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Low | <0.8 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – High | >2 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Quantity | 2 (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Circuit | Source (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Input resistance | 1470 Ω (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Limit switch inputs – Switching delay | Max. 100 µs (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.) |
| Quantity | 1 |
| Type | SinCos |
| Module-side connection | 15-pin female springtec connector |
| Status indicators | UP/DN LEDs |
| Encoder monitoring | Yes |
| Max. encoder cable length | 10 m |
Enable inputs
| Electrical isolation – Input - Inverter module | Yes |
| Electrical isolation – Input - Input | Yes |
| Input voltage – Nominal | 24 VDC |
| Input voltage – Maximum | 30 VDC |
| Switching threshold – Low | <5 V |
| Switching threshold – High | >15 V |
| Switching delay at nominal input voltage – Enable 1 → 0, PWM off | Max. 20.5 ms |
| Switching delay at nominal input voltage – Enable 0 → 1, ready for PWM | Max. 100 µs |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | Approx. 30 mA |
| Modulation compared to ground potential | Max. ±38 V |
| OSSD signal connections | Permitted ; Max. test pulse length: 500 µs (note: Output signal switching device (OSSD) signals are used for monitoring signal lines for short circuits and cross faults.) |
| Variant | 15-pin male TYCO connector (note: It is important to note that the 15-pin male TYCO connector is designed for max. 20 mating cycles.) |
Trigger inputs
| Electrical isolation – Input - Inverter module | No |
| Electrical isolation – Input - Input | No |
| Input voltage – Nominal | 24 VDC |
| Input voltage – Maximum | 30 VDC |
| Switching threshold – Low | <5 V |
| Switching threshold – High | >15 V |
| Switching delay – Rising edge | In preparation |
| Switching delay – Falling edge | In preparation |
| Sensor/Actuator power supply – Voltage | 24 VDC |
| Sensor/Actuator power supply – Summation current | Max. 250 mA (note: The summation current corresponds to the current that is output on the X23A and X24A connectors on the module.) |
| Quantity | 2 |
| Circuit | Sink |
| Input current at nominal voltage | In preparation |
| Modulation compared to ground potential | In preparation |
| Max. line length | 30 m |
| Variant | M8 connector |
Temperature sensor connection
| Quantity | 1 |
| Resistance range | 500 Ω to 5 kΩ |
Support
| Software – ACP10 | V2.35.1 and higher |
Electrical properties
| Energy efficiency (IE classification) – Power dissipation relative to continuous apparent power | IE2 (10,25) 1.3% ; IE2 (50,25) 1.3% ; IE2 (10,50) 1.6% ; IE2 (50,50) 1.6% ; IE2 (90,50) 1.6% ; IE2 (10,100) 2.2% ; IE2 (50,100) 2.2% ; IE2 (90,100) 2.2% |
| Energy efficiency (IE classification) – Nominal losses in standby mode | 6.5 W |
| Discharge capacitance | 0.1 µF |
Operating conditions
| Permissible mounting orientations – Hanging vertically | Yes |
| Permissible mounting orientations – Horizontal, face up | Yes |
| Permissible mounting orientations – Standing horizontally | Yes |
| Installation elevation above sea level – Nominal | 0 to 500 m |
| Installation elevation above sea level – Maximum | 4000 m (note: Continuous operation at an installation elevation of 500 m to 4,000 m above sea level is possible taking the specified reduction of continuous current into account. Requirements that go beyond this must be arranged with B&R.) |
| Flow rate – Minimum | 3 l/min (note: Valid under the following conditions: Coolant = Tap water. Values vary depending on the coolant and/or connection fitting being used!) |
| Flow rate – Maximum | 6 l/min (note: Valid under the following conditions: Coolant = Tap water. Values vary depending on the coolant and/or connection fitting being used!) |
| Pressure drop depending on flow volume – 3 l/min | Typ. 0.3 bar |
| Pressure drop depending on flow volume – 6 l/min | Typ. 0.7 bar |
| Pollution degree per EN 61800-5-1 | 2 (non-conductive pollution) |
| Overvoltage category per EN 61800-5-1 | III |
| Max. continuous pressure | 5 bar (note: The requirements of the complete system (tubing, heat exchangers, recooling systems, etc.) as well as any necessary application-specific requirements must be taken into account.) |
| Max. permissible return temperature | 60°C |
| Degree of protection per EN 60529 | IP65 |
Ambient conditions
| Temperature – Nominal | 5 to 40°C (note: The temperature of the module's mounting surface is not permitted to exceed 60°C.) |
| Temperature – Maximum | 60°C |
| Temperature – Storage | -25 to 55°C |
| Temperature – Transport | -25 to 70°C |
| Relative humidity – Operation | 5 to 85%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | Max. 95% at 40°C |
Mechanical properties
| Dimensions – Width | 137 mm (note: The dimensions refer to the actual device dimensions. Additional spacing above and below the devices must be taken into account for mounting and connection.) |
| Dimensions – Height | 287.2 mm (note: The dimensions refer to the actual device dimensions. Additional spacing above and below the devices must be taken into account for mounting and connection.) |
| Dimensions – Depth | 131 mm (note: The dimensions refer to the actual device dimensions. Additional spacing above and below the devices must be taken into account for mounting and connection.) |
| Weight | In preparation |
No matching specifications
Accessories
Optional accessories (28)
| 8CCH0010.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8CCH0007.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8CCH0005.11120-1 | 8BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H… |
| 8CCH0025.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 25 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CCH0020.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 20 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CCH0015.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 15 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CCH0010.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 10 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CCH0007.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 7 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CCH0005.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 5 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CCH0002.11150-1 | 8CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 2 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x… |
| 8CXM000.0000-00 | Accessory sets — ACOPOSremote accessory set: 4x hex socket screw M6x80mm for 8CVI inverter modules |
| 8CXC000.0000-00 | Accessory sets — Accessory set: 1x slot cover for hybrid connector |
| 8CCH0020.11110-1 | Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s… |
| 8CCH0015.11110-1 | Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s… |
| 8CCH0010.11110-1 | Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s… |
| 8CCH0005.11110-1 | Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s… |
| 8CCH0003.11130-1 | Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s… |
| 8CCH0003.11110-1 | Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s… |
| 8CCM0015.11110-0 | Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m… |
| 8CCM0010.11110-0 | Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m… |
| 8CCM0005.11110-0 | Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m… |
| 8CCM0003.11110-0 | Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m… |
| 8CCS0015.11110-0 | SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit… |
| 8CCS0010.11110-0 | SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit… |
| 8CCS0005.11110-0 | SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit… |
| 8CCS0003.11110-0 | SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit… |
| X67AC0M12 | Threaded Caps — X67 M12 threaded caps, 50 pcs. |
| X67AC0M08 | Threaded caps — X67 M8 threaded caps, 50 pcs. |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
8CVI155S1HCS0.01-1: frequently asked questions
When can 8CVI155S1HCS0.01-1 be shipped?
8CVI155S1HCS0.01-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 8CVI155S1HCS0.01-1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 8CVI155S1HCS0.01-1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8CVI155S1HCS0.01-1, subject to availability and destination.
More B&R parts