What is the B&R 8CVI155S1HCS0.01-1?

ACOPOSremote ACOPOSmulti65 inverter module, 15.5 A, AS, IP65, integrated cold plate, 1x SinCos encoder interface, cold plate mounting

Specifications

General information

Current-carrying capacity of 15-pin TYCO connector – Power contactsMax. 20 A at 40°C
Support – Dynamic node allocation (DNA)Yes
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – Functional safetyYes
Certifications – ULcULus E225616; Power conversion equipment
Module typeACOPOSremote module with integrated cold plate
B&R ID code0xE9EB
Cooling and mounting typeWall mounting ; Water cooling

DC bus connection

Voltage – Nominal750 VDC
Power dissipation depending on switching frequency – Switching frequency 5 kHzIn preparation
Power dissipation depending on switching frequency – Switching frequency 10 kHzIn preparation
Power dissipation depending on switching frequency – Switching frequency 20 kHzIn preparation
Line length – Maximum30 m
Continuous power consumptionIn preparation (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
DC bus capacitance35 µF
Variant15-pin male TYCO connector (note: It is important to note that the 15-pin male TYCO connector is designed for max. 20 mating cycles.)

24 VDC power supply

Line length – Maximum30 m
Input voltage24 VDC +20% / -25%
Input capacitanceIn preparation
Max. power consumption10 W + P 24 V out + P Holding brake + P Trigger (note: The power consumption P 24 V Out corresponds to the portion of the power that is output on the X31 connector on the module.)
Variant15-pin male TYCO connector (note: It is important to note that the 15-pin male TYCO connector is designed for max. 20 mating cycles.)

24 VDC output

Variant – 24 VDC, COMM8 connector
Quantity1
Output voltageDepends on the 24 VDC power supply
Continuous currentMax. 8 A (max. 4 A per pin)
Fuse protectionElectronic (per pin)

Motor connection

Reduction of continuous current depending on switching frequency – Switching frequency 5 kHzNo reduction (note: Valid under the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.)
Reduction of continuous current depending on switching frequency – Switching frequency 10 kHzIn preparation (note: Valid under the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.)
Reduction of continuous current depending on switching frequency – Switching frequency 20 kHzIn preparation (note: Valid under the following conditions: 750 VDC DC bus voltage. The temperature specifications refer to the ambient temperature.)
Reduction of continuous current depending on installation elevation – Starting at 500 m above sea level1.4 A per 1,000 m
Protective measures – Overload protectionYes
Protective measures – Short-circuit and ground fault protectionYes
Variant – U, V, W, PE8-pin speedtec connector, size 1
Variant – Shield connectionYes (via connector housing)
Max. motor line length depending on switching frequency – Switching frequency 5 kHz10 m
Max. motor line length depending on switching frequency – Switching frequency 10 kHz5 m
Max. motor line length depending on switching frequency – Switching frequency 20 kHz5 m
Quantity1
Continuous power per motor connection7.5 kW (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Continuous current per motor connection15.5 A eff (note: Valid under the following conditions: 750 VDC DC bus voltage, 5 kHz switching frequency, 40°C ambient temperature, installation elevation <500 m above sea level, no derating due to cooling type.)
Peak current40 A
Nominal switching frequency5 kHz
Possible switching frequencies5 / 10 / 20 kHz (note: B&R recommends operating the module at its nominal switching frequency. Operating the module at a higher switching frequency for application-specific reasons reduces the continuous current and increases CPU utilization.)
Insulation stress of the connected motor per IEC TS 60034-25:2004Limit value curve A
Max. output frequency598 HzPower unit: Limit speed exceeded").">

Motor holding brake connection

Protective measures – Overload and short-circuit protectionYes
Protective measures – Open-circuit monitoringYes
Protective measures – Undervoltage monitoringYes
Quantity1
Output voltage24 VDC +5.8% / -0% (note: During configuration, it is necessary to check if the minimum voltage can be maintained on the holding brake with the intended wiring. For the operating voltage range of the holding brake, see the user documentation for the motor being used.)
Continuous current per connection1.1 A
Max. internal resistanceIn preparation
Extinction potentialApprox. 30 V
Max. extinction energy per switching operation1.5 Ws
Max. switching frequency0.5 Hz
Response threshold for open-circuit monitoringApprox. 0.25 A
Response threshold for undervoltage monitoring24 VDC +0% / -4%

Fieldbus

TypePOWERLINK (V1/V2) 100BASE-T (ANSI/IEE 802.3)
VariantInternal 3-port hub, 2x male 15-pin TYCO connector, 1x M12 connector
Line lengthMax. 100 m between two stations (segment length) (note: Limited to 30 m when using hybrid cables.)
Transfer rate100 Mbit/s

Encoder inputs

Electrical isolation – Encoder - ACOPOSremoteNo
Encoder power supply – Overload-proofYes
Encoder power supply – Short-circuit proofYes
Encoder power supply – Output voltage5 V ±5%
Encoder power supply – Load capacity300 mA (note: An additional reserve of 12 mA exists for terminating resistors and limit switch inputs.)
Encoder power supply – Sense lines2, compensation of max. 2 x 0.7 V
Sine/Cosine inputs – Signal transmissionDifferential signals, symmetrical
Sine/Cosine inputs – Signal frequency (-3 dB)DC up to 300 kHz
Sine/Cosine inputs – Signal frequency (-5 dB)DC up to 400 kHz
Sine/Cosine inputs – Differential voltage0.5 to 1.25 V ss
Sine/Cosine inputs – Common-mode voltageMax. ±7 V
Sine/Cosine inputs – Terminating resistor120 Ω
Sine/Cosine inputs – ADC resolution12-bit
Reference input – Signal transmissionDifferential signal, symmetrical
Reference input – Differential voltage for low≤-0.2 V
Reference input – Differential voltage for high≥0.2 V
Reference input – Common-mode voltageMax. ±7 V
Reference input – Terminating resistor120 Ω
Position – Resolution @ 1 V SSNumber of encoder lines * 5700 (note: This value does not correspond to the encoder resolution that must be configured in Automation Studio (16384 * number of encoder lines).)
Position – Accuracy- (note: Limited by the encoder in practice.)
Position – Noise- (note: Limited by the encoder in practice.)
Limit switch inputs – Input - ACOPOSremoteNo (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Input - InputNo (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Minimum-12 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Nominal5 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Maximum20 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Low<0.8 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – High>2 V (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Quantity2 (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – CircuitSource (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Input resistance1470 Ω (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Limit switch inputs – Switching delayMax. 100 µs (note: The measurement system offered by Heidenhain with limit switch outputs LIDA 47x, LIDA 48x and LIF4x1 was tested for compatibility. In practice, the cable length is limited by the encoder.)
Quantity1
TypeSinCos
Module-side connection15-pin female springtec connector
Status indicatorsUP/DN LEDs
Encoder monitoringYes
Max. encoder cable length10 m

Enable inputs

Electrical isolation – Input - Inverter moduleYes
Electrical isolation – Input - InputYes
Input voltage – Nominal24 VDC
Input voltage – Maximum30 VDC
Switching threshold – Low<5 V
Switching threshold – High>15 V
Switching delay at nominal input voltage – Enable 1 → 0, PWM offMax. 20.5 ms
Switching delay at nominal input voltage – Enable 0 → 1, ready for PWMMax. 100 µs
Quantity2
CircuitSink
Input current at nominal voltageApprox. 30 mA
Modulation compared to ground potentialMax. ±38 V
OSSD signal connectionsPermitted ; Max. test pulse length: 500 µs (note: Output signal switching device (OSSD) signals are used for monitoring signal lines for short circuits and cross faults.)
Variant15-pin male TYCO connector (note: It is important to note that the 15-pin male TYCO connector is designed for max. 20 mating cycles.)

Trigger inputs

Electrical isolation – Input - Inverter moduleNo
Electrical isolation – Input - InputNo
Input voltage – Nominal24 VDC
Input voltage – Maximum30 VDC
Switching threshold – Low<5 V
Switching threshold – High>15 V
Switching delay – Rising edgeIn preparation
Switching delay – Falling edgeIn preparation
Sensor/Actuator power supply – Voltage24 VDC
Sensor/Actuator power supply – Summation currentMax. 250 mA (note: The summation current corresponds to the current that is output on the X23A and X24A connectors on the module.)
Quantity2
CircuitSink
Input current at nominal voltageIn preparation
Modulation compared to ground potentialIn preparation
Max. line length30 m
VariantM8 connector

Temperature sensor connection

Quantity1
Resistance range500 Ω to 5 kΩ

Support

Software – ACP10V2.35.1 and higher

Electrical properties

Energy efficiency (IE classification) – Power dissipation relative to continuous apparent powerIE2 (10,25) 1.3% ; IE2 (50,25) 1.3% ; IE2 (10,50) 1.6% ; IE2 (50,50) 1.6% ; IE2 (90,50) 1.6% ; IE2 (10,100) 2.2% ; IE2 (50,100) 2.2% ; IE2 (90,100) 2.2%
Energy efficiency (IE classification) – Nominal losses in standby mode6.5 W
Discharge capacitance0.1 µF

Operating conditions

Permissible mounting orientations – Hanging verticallyYes
Permissible mounting orientations – Horizontal, face upYes
Permissible mounting orientations – Standing horizontallyYes
Installation elevation above sea level – Nominal0 to 500 m
Installation elevation above sea level – Maximum4000 m (note: Continuous operation at an installation elevation of 500 m to 4,000 m above sea level is possible taking the specified reduction of continuous current into account. Requirements that go beyond this must be arranged with B&R.)
Flow rate – Minimum3 l/min (note: Valid under the following conditions: Coolant = Tap water. Values vary depending on the coolant and/or connection fitting being used!)
Flow rate – Maximum6 l/min (note: Valid under the following conditions: Coolant = Tap water. Values vary depending on the coolant and/or connection fitting being used!)
Pressure drop depending on flow volume – 3 l/minTyp. 0.3 bar
Pressure drop depending on flow volume – 6 l/minTyp. 0.7 bar
Pollution degree per EN 61800-5-12 (non-conductive pollution)
Overvoltage category per EN 61800-5-1III
Max. continuous pressure5 bar (note: The requirements of the complete system (tubing, heat exchangers, recooling systems, etc.) as well as any necessary application-specific requirements must be taken into account.)
Max. permissible return temperature60°C
Degree of protection per EN 60529IP65

Ambient conditions

Temperature – Nominal5 to 40°C (note: The temperature of the module's mounting surface is not permitted to exceed 60°C.)
Temperature – Maximum60°C
Temperature – Storage-25 to 55°C
Temperature – Transport-25 to 70°C
Relative humidity – Operation5 to 85%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – TransportMax. 95% at 40°C

Mechanical properties

Dimensions – Width137 mm (note: The dimensions refer to the actual device dimensions. Additional spacing above and below the devices must be taken into account for mounting and connection.)
Dimensions – Height287.2 mm (note: The dimensions refer to the actual device dimensions. Additional spacing above and below the devices must be taken into account for mounting and connection.)
Dimensions – Depth131 mm (note: The dimensions refer to the actual device dimensions. Additional spacing above and below the devices must be taken into account for mounting and connection.)
WeightIn preparation

Accessories

Optional accessories (28)
8CCH0010.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8CCH0007.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8CCH0005.11120-18BVE / 8CVI connection cables — Can be used in cable drag chains; Cable for connection of ACOPOSremote / ACOPOSmotor drive systems to ACOPOSmulti 8BVE expansion modules; H…
8CCH0025.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 25 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CCH0020.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 20 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CCH0015.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 15 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CCH0010.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 10 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CCH0007.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 7 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CCH0005.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 5 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CCH0002.11150-18CVI / 8DI connection cables — Hybrid cable for connecting 8EI to 8CVI or 8DI, length 2 m, 2x 2x 0.34 mm² + 4x 0.75 mm² + 5x 2.5 mm², 1x 15-pin female TYCO connector, 1x…
8CXM000.0000-00Accessory sets — ACOPOSremote accessory set: 4x hex socket screw M6x80mm for 8CVI inverter modules
8CXC000.0000-00Accessory sets — Accessory set: 1x slot cover for hybrid connector
8CCH0020.11110-1Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s…
8CCH0015.11110-1Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s…
8CCH0010.11110-1Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s…
8CCH0005.11110-1Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s…
8CCH0003.11130-1Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s…
8CCH0003.11110-1Hybrid cables — Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote/ACOPOSmotor drive systems; Hybrid connector system for s…
8CCM0015.11110-0Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m…
8CCM0010.11110-0Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m…
8CCM0005.11110-0Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m…
8CCM0003.11110-0Motor cables 1.5 mm² — UL/CSA listed; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors with m…
8CCS0015.11110-0SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit…
8CCS0010.11110-0SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit…
8CCS0005.11110-0SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit…
8CCS0003.11110-0SinCos cables — UL/CSA certified; Can be used in cable drag chains; Assembled specifically for use with ACOPOSremote drive systems and B&R servo motors wit…
X67AC0M12Threaded Caps — X67 M12 threaded caps, 50 pcs.
X67AC0M08Threaded caps — X67 M8 threaded caps, 50 pcs.

8CVI155S1HCS0.01-1: frequently asked questions

When can 8CVI155S1HCS0.01-1 be shipped?

8CVI155S1HCS0.01-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 8CVI155S1HCS0.01-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 8CVI155S1HCS0.01-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 8CVI155S1HCS0.01-1, subject to availability and destination.

More B&R parts

B&R 8CVI088E1HCS0.00-1 – ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65
B&R
8CVI088E1HCS0.00-1

ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65

B&R 8CVI088H1HCS0.00-1 – ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65
B&R
8CVI088H1HCS0.00-1

ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65

B&R 8CVI088S1HCS0.00-1 – ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65
B&R
8CVI088S1HCS0.00-1

ACOPOSremote ACOPOSmulti65 inverter module, 8.8 A, AS, IP65

B&R 8CXC000.0000-00 – Accessory set: 1x slot cover for hybrid connector
B&R
8CXC000.0000-00

Accessory set: 1x slot cover for hybrid connector

B&R 8CXC001.0000-00 – ACOPOSremote accessory set: 2x bridge, 2-pin
B&R
8CXC001.0000-00

ACOPOSremote accessory set: 2x bridge, 2-pin

B&R 8CXC001.0002-00 – ACOPOSremote accessory set: 20x bridge, 2-pin
B&R
8CXC001.0002-00

ACOPOSremote accessory set: 20x bridge, 2-pin

B&R 8CXC001.0005-00 – ACOPOSremote accessory set: 50x bridge, 2-pin
B&R
8CXC001.0005-00

ACOPOSremote accessory set: 50x bridge, 2-pin

B&R 8CVI155S1HCS0.01-1Price and lead time confirmed within 1 business day
Request a Quote