General
| Description | 2010 Digital Output Module, 16 relay outputs 240 VAC / 30 VDC, 4 A, single channel isolated outputs, Order terminal blocks separately! |
| C-UL-US Listed | Yes |
| B&R ID Code | $27 |
| Base Plate Module | BP200, BP201, BP210 |
Static Characteristics
| Module Type | B&R 2010 I/O module single width |
| Number and Type of Outputs | 8 change-over 8 normally open Single channel isolation |
| Maximum Switching Voltage | 125 VDC / 264 VAC |
| Maximum Peak Voltage | Externally limited to max. 460 V |
| Rated Voltage | 30 VDC / 240 VAC |
| Switching Voltage Range | Min. 5 VDC @ 1 mA |
| Rated Frequency | DC or 45 - 63 Hz |
| Rated Current (1-Signal) Ie | 4 A (resistive load) |
| (continually at maximum voltage) – DC | 1 mA - 4 A (resistive load) |
| (continually at maximum voltage) – AC | 100 mA - 8 A (resistive load) |
| Switching Power | 2000 VA; 120 W @ 30 VDC (resistive load) |
| Contact Resistance (DC) | Max. 100 mΩ @ 6 VDC / 100 mA |
| Power Loss on Contact (AC) | Typ. 1 W (max. 5 W) |
| Fuse-R | External fuse |
| Connection | 8 change-over / 8 normally open |
| Power Consumption – Internal | Max. 7 W |
| Power Consumption – External | Max. 8 W |
Additional Characteristics
| Status Display | 1 yellow LED per channel |
Protective Characteristics
| Short Circuit Protection – AC | Fuse 8 A slow-blow (required externally) |
| Short Circuit Protection – DC | Fuse 4 A slow-blow (required externally) |
| Overvoltage Protection for Contacts | Limited to 460 V (required externally) |
| For DC Connection | Spark suppression if necessary (connected externally) |
Dynamic Characteristics
| Signal Change from log 0 - log 1 log 1 - log 0 | Max. 13 msec (incl. chatter time) Max. 13 msec (incl. chatter time) |
Operating Characteristics
| Effect of Incorrectly Connecting the Outputs | No implications for the module |
| Behaviour of Outputs by Controller | Outputs are reset in the event of malfunction |
| Failure through the Main Processing | (note normally closed contacts) |
| Total Output Current | max. 64 A |
| Following Conditions must be Fulfilled | Σ In² ≤ 400 see section "Total Output Current" |
| Wire Cross Section | 2.5 mm², for currents≥4 A or one of the recommended values is reached |
| Channel and – Bus | 1 Minute 2800 VAC or 4 kV @ 1.2 x 50 µsec pulse |
| Channel and – Other Channel | 1 Minute 1000 VAC or 1.4 kV @ 1.2 x 50 µsec pulse |
| Isolation between Open | 1 Minute 1000 VAC or 1.4 kV @ 1.2 x 50 µsec pulse |
| Different Phases Possible | Yes, but only for 110 VAC |
| Starting Point of LED for a Channel | Control signal from relay coil |
| Method of Operation | Latches set on bus using transistor relay drivers |
| Typical Example for External | Standard connection of normally open and change-over contacts, |
| Connections | Sink and source connections possible |
Mechanical Characteristics
| Dimensions | B&R 2010 single width |
Accessories
Optional accessories (1)
| 2TB140.9 | Undefined — 2010 terminal block, 40 pin Screw clamp |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
2DO710.6: frequently asked questions
When can 2DO710.6 be shipped?
2DO710.6 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 2DO710.6 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 2DO710.6 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 2DO710.6, subject to availability and destination.