What is the B&R 2AT610.6?
2010 analog input module 16 inputs, sensor type L/J/K -200 to +1300 degrees C Order terminal block 1 x TB140 separately!
Specifications
General
| Description | 2010 Analog Input Module, 16 inputs, temperature sensor, Type L/J/K, -200 to +1300 degrees C, Order terminal blocks separately! |
| C-UL-US Listed | Yes |
| B&R ID Code | $25 |
| Base Plate Module | BP200, BP201, BP210 |
| Number of Inputs | 16 differential inputs for thermocouples |
| Distribution | 4 groups |
| Group 1 | Channels 1 - 4 |
| Group 2 | Channels 5 - 8 |
| Group 3 | Channels 9 - 12 |
| Group 4 | Channels 13 - 16 |
| Input Signal – Nominal | -15 to +55 mV |
| Input Signal – Allowed | -20 to +20 V |
| Differential Input Resistance | >1 MΩ |
| Input Filter | Bessel low pass 2nd order, cutoff frequency 8 Hz, Measured using NOTCH characteristic method (according to measurement time) |
| Common Mode Rejection | 80 dB (DC) 75 dB (50 Hz) |
| Max. Modulation – Compared to Ground between 2 Elect. Isolated Groups | ±50 V ±50 V |
| Common Mode Control between | ±9 V |
| Electrical Isolation – Input - PCC | Yes |
| Electrical Isolation – Group 1 - Group 3 | No |
| Electrical Isolation – Group 2 - Group 4 | No |
| Electrical Isolation – Groups 1+3 - Groups 2+4 | Yes |
| Electrical Isolation – Input - Input (same group) | No |
| Measurement Procedure – Conversion Principle | Integrated (voltage / frequency converter) |
| Measurement Procedure – Measurement Time per Channel | Can be set to 20 msec / 16.67 msec / 10 msec / 8.33 msec (AT610 operation) |
| Resolution | Internal >14 Bit (23841 internal ADC converter values at 20 msec) |
| Quantization – Internal | 2.936 µV |
| Quantization – Output | 0.1 °C (temperature measurement) 2.0 µV (scaled voltage raw value) |
| Internal Reference Junction – Temperature Determination | Temperature profile measurement in module with four temperature sensors Reference junction temperature determined for each channel separately |
| Internal Reference Junction – Measurement Precision | Max. ±4 °C over entire environmental temperature range (0 to 60 °C) |
| Internal Reference Junction – ( natural convection) | Typ. +3 °C / -1 °C at 25 °C environmental temperature |
| Internal Reference Junction – Repeat Precision | ±0.1 °C |
| Status Display – Terminal ok | Red |
| Status Display – RUN LED | Green |
| Status Display – 10 Status LEDs | Yellow |
| Operating Modes | AT600 compatible (standard setting) AT610 |
| Power Consumption | Max. 8 W |
| Dimensions (H, W, D) [mm] | 285, 40, 185 |
| Operating Mode | AT610 |
| Sensor – Model | FeCuNi FeCuNi NiCrNi Raw Value Measurement |
| Sensor – Type | L J K ---- |
| Sensor – Standard | DIN 43710 DIN IEC 584 DIN IEC 584 Scaled to 2 µV |
| Sensor – Measurement Voltage Range | -8.15 to 53.14 mV 2) -7.89 to 54.95 mV 2) -5.891 to 52.398 mV 2) -15 to +55 mV |
| Measurement Range in 0.1 °C Steps | -200.0 to +900.0 °C -200.0 to +950.0 °C -200.0 to +1300.0 °C According to sensor |
| Linearization | Yes Yes Yes in CPU |
| Reference Junction Measurement – Internal | -20 to +90 °C Can be read |
| Reference Junction Measurement – External | -100 to +200 °C (can be set) ---- |
| Conversion Time – Measurement Time per Conversion | Can be set to 20 msec / 16.67 msec / 10 msec / 8.33 msec |
| Conversion Time – Calculation Time per Channel Pair | 6 msec |
| Conversion Time – Measurement Time for Internal | 26 msec |
| Maximum Cycle Time | 50 Hz 60 Hz 8 * (meas. time per conversion + calc. time) 8 * (20 + 6) msec 8 * (16.67 + 6) msec Reference junction meas. (if activated) 26 msec 26 msec Results in a cycle time of 234 msec 207.36 msec |
| Basic Precision at 25 °C | ±25 µV (±0.036 %) |
| Offset Drift | ±1.1 µV/°C (±0.0016 %/°C) |
| Gain Drift | ±0.006 %/°C |
| Repeat Precision (meas. time 20 msec) | ±0.008 % |
| Operating Mode | AT600 |
| Sensor – Model | FeCuNi |
| Sensor – Type | L |
| Sensor – Standard | DIN 43710 |
| Measurement Range in 0.1 °C Steps | -50.0 to +750.0 °C |
| Linearization | Yes |
| Terminal Temperature Compensation | -20 to +90 °C from internal reference junction measurement |
| Conversion Time – Measurement Time per Conversion | 20 msec |
| Conversion Time – Maximum Cycle Time | 235 msec |
Accessories
Optional accessories (1)
| 2TB140.9 | Undefined — 2010 terminal block, 40 pin Screw clamp |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
2AT610.6: frequently asked questions
When can 2AT610.6 be shipped?
2AT610.6 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 2AT610.6 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 2AT610.6 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 2AT610.6, subject to availability and destination.