Beckhoff – IP1502-B800 Fieldbus Box, 2-channel digital input, RS485, counter, 24 V DC, 100 kHz, M12
Discontinued by Beckhoff — we can still source the original IP1502-B800 (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | I/O service products (discontinued) |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
Can I still buy the IP1502-B800 now that it is discontinued?
Yes. Beckhoff has discontinued the IP1502-B800, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can IP1502-B800 be shipped?
IP1502-B800 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up IP1502-B800 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for IP1502-B800 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for IP1502-B800, subject to availability and destination.
The counter module has two fast counters running at up to 100 kHz. It counts binary pulses, and transmits the counter state to the higher-level automation unit. The up/down input allows the counters to be switched between upwards and downwards counting
Beckhoff IP1502-B800 — Fieldbus Box, 2-channel digital input, RS485, counter, 24 V DC, 100 kHz, M12. Beckhoff service-phase product: no longer in the current range. PartnerPLC sources discontinued and surplus Beckhoff automation parts — request a quote for price, condition and lead time.
Specifications
Technical data
| Lifecycle | Service phase (discontinued, no longer in Beckhoff's product range) |
| Specification | EN 61131-2, type 2 |
| Number of inputs | 2 counter inputs + 2 gate inputs + 2 up/down switches |
| Input connections | M12, screw type |
| Number of counters | 2, each with a depth of 32 bits |
| Counting frequency | 100 kHz (2 kHz for switching between up and down) |
| Nominal input voltage | 24 V DC (-15%/+20%) |
| Input filter | – |
| “0” signal voltage | -3…+5 V (EN 61131-2, type 2) |
| “1” signal voltage | 11…30 V (EN 61131-2, type 2) |
| Number of outputs | 2 x 24 V DC, 0.5 A, individually short-circuit-proof |
| Sensor supply | from control voltage, max. 0.5 A, short-circuit proof in total |
| Power supply connection | feed: 1 x M8 male socket, 4-pin, a-coded; downstream connection: 1 x M8 female socket, 4-pin, a-coded |
| Bit width in the process image | 80 inputs/outputs: 2 x 32 bit data (2 x 8 bit control/status) |
| Current consumption from U S (without sensor current) | see documentation |
| Electrical isolation | channels/control voltage: no, between the channels: no, control voltage/fieldbus: depends on the bus system |
| Extension modules | – |
| Digital peripheral signals | according to I/O type |
| Analog peripheral signals | according to I/O type |
| Protocol | open, documented protocol |
| Configuration | via KS2000 |
| Data transfer rates | 9.6 kbaud, 19.2 kbaud, 38.4 kbaud (default) |
| Bus interface | 1 x M12 socket, 5-pin, B-coded |
| Data transfer medium | shielded copper cable, 2 x 0.25 mm² |
| Power supply | control voltage: 24 V DC (-15%/+20%); load voltage: according to I/O type |
| Box supply current | 45 mA + current consumption of sensors, max. 0.5 A |
| Auxiliary power current | according to I/O type |
| Weight | approx. 210 g |
| Operating temperature | 0…55°C |
| Storage temperature | -25…+85°C |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP65/66/67 (conforms to EN 60529)/variable |
| Approvals/markings | CE, UL |
More Beckhoff parts
Available on requestFieldbus Box, 2-channel digital input, CANopen, counter, 24 V DC, 100 kHz, M12, integrated T-connector
Available on requestFieldbus Box, 2-channel digital input, DeviceNet®, counter, 24 V DC, 100 kHz, M12
Available on requestFieldbus Box, 2-channel digital input, DeviceNet®, counter, 24 V DC, 100 kHz, M12, integrated T-connector
Available on requestIP1502-B730 Fieldbus Box, 2-channel digital input, Modbus, counter, 24 V DC, 100 kHz, M12
Available on requestIP1502-B810 Fieldbus Box, 2-channel digital input, RS232, counter, 24 V DC, 100 kHz, M12
Available on requestFieldbus Box, 2-channel digital input, counter, 24 V DC, 100 kHz, M12
Available on requestIP2000-B200 Fieldbus Box, 8-channel digital output, Lightbus, 24 V DC, 0.5 A, Ø8
Available on requestIP2000-B310 Fieldbus Box, 8-channel digital output, PROFIBUS, 24 V DC, 0.5 A, Ø8