Allen-Bradley – 284D-FVD6P0S-25-CR-DB1-SB ArmorStart VFD Safety RP CM
Discontinued by Rockwell Automation / Allen-Bradley — we can still source the original 284D-FVD6P0S-25-CR-DB1-SB (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ArmorStart Distributed Motor Controllers |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
Can I still buy the 284D-FVD6P0S-25-CR-DB1-SB now that it is discontinued?
Yes. Rockwell Automation / Allen-Bradley has discontinued the 284D-FVD6P0S-25-CR-DB1-SB, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can 284D-FVD6P0S-25-CR-DB1-SB be shipped?
284D-FVD6P0S-25-CR-DB1-SB is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 284D-FVD6P0S-25-CR-DB1-SB in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 284D-FVD6P0S-25-CR-DB1-SB and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 284D-FVD6P0S-25-CR-DB1-SB, subject to availability and destination.
Allen-Bradley 284D-FVD6P0S-25-CR-DB1-SB — ArmorStart VFD Safety RP CM. Discontinued by Rockwell Automation on October 08, 2024. PartnerPLC supplies new, surplus and discontinued Allen-Bradley parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Discontinued |
| Discontinued date | October 08, 2024 |
| Replacement category (Rockwell) | Engineering Replacement |
| Repair options available | Yes |
Specifications
| Communications | DeviceNet |
| Option 2 | Source Brake Contactor |
| Option 3 | No Selection for |
| Torque Performance | Sensorless Vect Ctrl and V/Hz |
| 3-phase power/motor cable connection | Conduit entrance with motor cable |
| Altitude | 1000 m |
| Application in industrial area permitted | true |
| Application in industrial area permitted (SCPD list) | Size per NFPA 70 (NEC) or NFPA 79 for group motor applications |
| Baud rates | 125, 250, 500 kbps |
| Communication | DeviceNet |
| Conducted radio frequency emissions | Class A |
| Connection type | Quick disconnects |
| Conventional thermal current (Ith) | Output rating- sourced from control circuit: total of both outputs ≤2 A |
| Current available | Sensor source: 50 mA maximum per input, 200 mA total |
| Degree of protection (IP) | IP67 |
| Degree of protection (NEMA) | 4 |
| Depth, approx | 266.9 mm @ 460V AC, conduit entrance, 3 Hp and above |
| DeviceNet input current | 364mA @ 11V DC - 4.0 W |
| DeviceNet input current surge | 15 A for 250 µs |
| DeviceNet supply voltage rating | Range 11...25V DC @ 24V DC nominal |
| Dielectric withstand | Power circuit: 2500V AC per IEC |
| Disconnect | Motor disconnect |
| Disconnect lock out | Recommend 8 mm (5/16 in) lock shackle or hasp. The hasp should not exceed 8 mm (5/16 in) when closed. |
| Distance, max | 500 m (1630 ft) @ 125 kbps |
| Drive input current ratings | 9.00A @ 380V, 2.2 kW, 3-phase, 50 Hz |
| Electrostatic discharge | 4 kV contact and 8 kV Air |
| Enclosure type | IP67/NEMA 4 |
| External devices powered by DeviceNet | 50 mA - total 200 mA |
| Fast transient | 2 kV |
| Height, approx | 287.5 mm @ 460V AC, conduit entrance, 3 Hp and above |
| Humidity | 5...95% on-condensing |
| Input compatibility | IEC 1133 Type 1+ |
| Input filter - software selectable | ON to OFF: Settable from 0…64 ms in 1 ms increments |
| Input OFF-state current | <1.5 mA |
| Input OFF-state voltage | 0...5V DC |
| Input ON-state current | 7.2mA @ 24V DC |
| Input ON-state voltage | 10...26V DC |
| Insulation voltage | Power circuit: rated 600V AC |
| Kind of current | Output rating- sourced from control circuit: AC/DC |
| Mains frequency | 50/60 Hz |
| Max. output frequency | 400 Hz |
| Nominal control power (hold in) | External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor |
| Nominal control power (pick up) | External devices powered by control voltage: 64 W @ with maximum outputs, with brake and output contactor |
| Number of contacts | Output rating- sourced from control circuit: 2 |
| Number of digital inputs | 4 |
| Number of digital outputs | 2 |
| Number of inputs | 4 |
| Number of poles | 3 |
| Operating frequency | Power circuit: 50/60 Hz |
| Operating temperature | -20 °C |
| Option 2 | M25 source brake contactor connector |
| Output current | 6.0 A, 2.2 kW, 3.0Hp @ 380...480V, 50/60 Hz, 3-phase |
| Outputs current (2) 1 A each, max | External devices powered by control voltage: 2 A @ with brake and output contactor |
| Overload protection | I²t overload protection - 150% @ 60s, 200% @ 30s |
| Overvoltage category | Control circuit: III per IEC |
| Pollution degree | 3 |
| Product type | AC Drive |
| Protection against shock | Power circuit: IP2X per IEC |
| Radiated emissions | Class A, group 1, equivalent to C2 emissions |
| Radio frequency electromagnetic field | 10 V/m |
| Rated impulse voltage | Power circuit: rated 6 kV |
| Rated input operation voltage | 24V DC |
| Rated operation voltage | Power circuit: 380Y/220...480Y/277V AC |
| Rated output operation voltage | Sourced from control circuit: 240V AC / 30V DC |
| RMS symmetrical amperes | 30 kA @ 600Y/347V per IEC |
| Safety | Hardwired safety (STO) |
| Shipping weight, approx | 19.1 kg |
| Shock | opsal: 15 G |
| Short circuit protection | 25 A rated device |
| Short-circuit protection device list | Size per NEC group motor per UL/NEMA |
| Storage and transportation temperature | -25 °C |
| Supporting protocol for DeviceNet | true |
| Surge transient | 1 kV L-L, 2 kV L-N (earth) |
| Terminal wire size | Control and safety monitor inputs: #18... AWG per UL/NEMA |
| Tightening torque | Power and ground terminals: 4.5 in-lb per UL/NEMA (sary terminal) |
| Torque performance mode | Sensorless vector control and volts per Hz |
| Total w/max. sensor inputs (4) | 367mA @ 24V DC - 8.0 W |
| Trip class | Class 10 |
| Type of contacts | Output rating- sourced from control circuit: normally open (NO) |
| Type of control circuit | Output rating- sourced from control circuit: electromechanical relay |
| Utilization category | Power circuit: AC-3 per IEC |
| Vibration | opsal, 1 G, 0.15 mm (0.006 in) displacement |
| Voltage status | Sensor source: 11...25V DC from DeviceNet |
| Width, approx | 444.38 mm @ 460V AC, conduit entrance, 3 Hp and above |
| Wire size | Power and ground terminals: 1.5...4.0 mm² per IEC (primary/sary terminal) |
| Wire strip length | power and ground terminals: 9 mm (0.35 in) |
More Rockwell Automation / Allen-Bradley parts
Available on requestRockwell Automation / Allen-Bradley 281GS-F23S-25D-RRG-22
Available on requestRockwell Automation / Allen-Bradley 281GS-F23S-25D-RRG-3FR-00
Available on requestRockwell Automation / Allen-Bradley 281GS-F23S-25D-RRG-3FR-22
Available on request284D-FVD4P0S-10-CRW-DB1-SB ArmorStart VFD Safety RP CM
Available on requestRockwell Automation / Allen-Bradley 284D-FVD6P0Z-25-RRW-3-SB
Available on requestRockwell Automation / Allen-Bradley 284E-FVD1P4Z-10-RR
Available on requestRockwell Automation / Allen-Bradley 284E-FVD1P4Z-10-RR-3-DB-SB-EMI-OC