Acim Nidec Commander C
Flexibility for countless applications
- MPN
- Commander C
- Category
- Connect
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
- 100% positive eBay feedback
What is the Acim Nidec Commander C?
Flexibility for countless applications
Commander C combines efficiency and reliability to offer optimum performance for a wide range of applications. With many essential features built in, including PLC capabilities for simple programming needs, dual STO safety function, braking transistor and PID control, it provides a compact solution for any installation.
Excellence in motor control
The ultimate all-in-one drive
.cell-white {
border-style: solid;
border-color: #FFFFFF;
background-color: #FFFFFF;
}
Whatever your application, Commander C is the perfect solution across industries
The Commander C series are simple and compact AC motor speed controllers that meet advanced requirements in a wide range of applications. Their small footprint – among the smallest in their class – makes them ideal for machine builders and OEMs, where size really matters.
Software
3D CAD Models
This product comes with 5-year warranty as standard
No registration. No extra cost. Just peace of mind from day one. Learn more .
Specifications
Specifications
| C300 C200 | |
| Open loop vector or V / Hz induction motor control | â â |
| Open loop Rotor Flux Control for induction motors (RFC-A) | â â |
| Sensorless permanent magnet motor control | |
| Ambient Operating Temperature | Size 1 - 4: -20 °C to 50 °C (-4 °F to 122 °F) @ 3 kHz switching freq. | Operation to 60°C (140°F) with de-rating Size 5 - 9: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 55°C (131°F) with de-rating Size 1 - 4: -20 °C to 50 °C (-4 °F to 122 °F) @ 3 kHz switching freq. | Operation to 60°C (140°F) with de-rating Size 5 - 9: -20°C to 40°C (-4°F to 104°F) @ 3 kHz switching freq. | Operation to 55°C (131°F) with de-rating |
| Cooling Method | Forced convection Forced convection |
| Humidity | 95 % non-condensing at 40 °C (104 °F) 95 % non-condensing at 40 °C (104 °F) |
| Storage Temperature | Size 1 - 4: -40°C to 60°C (-40°F to 140°F) — 24 months Max. Size 5 - 9: -40°C to 55°C (-40°F to 131°F) — 24 months Max. Size 1 - 4: -40°C to 60°C (-40°F to 140°F) — 24 months Max. Size 5 - 9: -40°C to 55°C (-40°F to 131°F) — 24 months Max. |
| Altitude | De-rate the continuous output current by 1% for every 100 m (328 ft) above 1000 m (3,280 ft) to a maximum of 3000 m (9,840 ft) De-rate the continuous output current by 1% for every 100 m (328 ft) above 1000 m (3,280 ft) to a maximum of 3000 m (9,840 ft) |
| Vibration | Tested in accordance with IEC 60068-2-64 and IEC 60068-2-6 Tested in accordance with IEC 60068-2-64 and IEC 60068-2-6 |
| Mechanical Shock | Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29 Tested in accordance with IEC 60068-2-27 and IEC 60068-2-29 |
| Enclosure Rating | IP20, NEMA 1 conduit kits available IP20, NEMA 1 conduit kits available |
| Electromagnetic Capability | IEC/ EN 61800-3 Immunity and Emissions EN 61000-6-2: Immunity for industrial environments EN 61000-6-4: Emissions for industrial environmentsM/br> EN 61000-3-2: Harmonic current emissions An EMC data sheet is available on request IEC/ EN 61800-3 Immunity and Emissions EN 61000-6-2: Immunity for industrial environments EN 61000-6-4: Emissions for industrial environmentsM/br> EN 61000-3-2: Harmonic current emissions An EMC data sheet is available on request |
| RoHS | Complies with the Restriction of Hazardous Substances Directive (2011/65/EU) Complies with the Restriction of Hazardous Substances Directive (2011/65/EU) |
| Voltage | 100 V to 120 V ±10 % 200 V to 240 V ±10 % 380 V to 480 V ±10 % 500 V to 575 V ±10 % 500 V to 690 V ±10 % 100 V to 120 V ±10 % 200 V to 240 V ±10 % 380 V to 480 V ±10 % 500 V to 575 V ±10 % 500 V to 690 V ±10 % |
| Phase | 1Ø and 3Ø (Model dependent) 1Ø and 3Ø (Model dependent) |
| Maximum Supply Imbalance | 2% negative phase sequence, 3% voltage imbalance between phases 2% negative phase sequence, 3% voltage imbalance between phases |
| Input Frequency | 45 to 66 Hz 45 to 66 Hz |
| Input Displacement Power Factor | 0.97 0.97 |
| Switching Frequency | Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz Size 1 - 4: 0.667, 1, 2, 3, 4, 6, 8 12 & 16 kHz Size 5 - 9: 2, 3, 4, 6, 8 12 & 16 kHz |
| Output Frequency Range | 0 to 550 Hz 0 to 550 Hz |
| Frequency Accuracy | ±0.02% of full scale ±0.02% of full scale |
| Frequency Resolution | 0.01 Hz 0.01 Hz |
| Analog Input Resolution | Voltage mode: 11 bits (unipolar) Current mode: 11 bits Voltage mode: 11 bits (unipolar) Current mode: 11 bits |
| Braking | Dynamic braking transistor included, requires external resistor Dynamic braking transistor included, requires external resistor |
| DC Bus Undervoltage Trip | 100 V models: 175 Vdc 200 V models: 175 Vdc 400 V models: 330 Vdc 575 V models: 435 Vdc 690 V models: 435 Vdc 100 V models: 175 Vdc 200 V models: 175 Vdc 400 V models: 330 Vdc 575 V models: 435 Vdc 690 V models: 435 Vdc |
| DC Bus Overvoltage Trip | Frame sizes 1 - 4: 100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc Frame sizes 1 - 4: 100 V models: 510 Vdc 200 V models: 510 Vdc 400V models: 870 Vdc |
| Drive Overload Trip | Programmable: Default settings: 180% for 3s, 150% for 60s Programmable: Default settings: 180% for 3s, 150% for 60s |
| Instantaneous Overcurrent Trip | 220% of rated motor current 220% of rated motor current |
| Phase Loss Trip | DC bus ripple threshold exceeded DC bus ripple threshold exceeded |
| Over-temperature Trip | Drive heatsink temperature exceeds 95°C (203°F) Drive heatsink temperature exceeds 95°C (203°F) |
| Short Circuit Trip | Protects against output phase-to-phase fault Protects against output phase-to-phase fault |
| Ground Fault Trip | Protects against output phase-to-ground fault Protects against output phase-to-ground fault |
| Motor Thermal Trip | Electronically protects the motor from overheating due to loading conditions Electronically protects the motor from overheating due to loading conditions |
| UL, cUL | UL file NMMS/8: E171230 UL file NMMS/8: E171230 |
| CE | CE approval CE approval |
| EU | These products comply with the Restriction of Hazardous Substances Directive (2011/65/EU), the Low Voltage Directive (2014/35/EU) and the Electromagnetic Compatibility Directive, (2014/30/EU). These products comply with the Restriction of Hazardous Substances Directive (2011/65/EU), the Low Voltage Directive (2014/35/EU) and the Electromagnetic Compatibility Directive, (2014/30/EU). |
| RCM | RCM Registered supplier No. 12003815281 RCM Registered supplier No. 12003815281 |
| ISO | Manufacturing facilities comply with ISO 9001:2015 and ISO 14001 Manufacturing facilities comply with ISO 9001:2015 and ISO 14001 |
| TÜV | C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine. Type examination certificates by TÜV Rheinland: Frame sizes 1 - 4: No. 01/205/5383.03/18 Frame sizes 5 - 9: No. 01/205/5387.02/18 Functional safety parameters: EN ISO 13849-1 - Cat 4, PLe EN61800-5-2/EN62061/IEC 61508 - SIL 3 UL functional safety approval: FSPC E171230 C300 models only: The Safe Torque Off (STO) function may be used as a safety component of a machine. Type examination certificates by TÜV Rheinland: Frame sizes 1 - 4: No. 01/205/5383.03/18 Frame sizes 5 - 9: No. 01/205/5387.02/18 Functional safety parameters: EN ISO 13849-1 - Cat 4, PLe EN61800-5-2/EN62061/IEC 61508 - SIL 3 UL functional safety approval: FSPC E171230 |
Commander C: frequently asked questions
When can Commander C be shipped?
Commander C is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up Commander C in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for Commander C and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for Commander C, subject to availability and destination.