Available on request

ABB 1SFL597001R6811 – AF460-30-11 24-60V DC Contactor

MPN: 1SFL597001R6811 · Brand: ABB
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryABB AF Contactors
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
Weight10.6 kg
Country of originIndia
UPC / EAN7320500217887

Shipping & availability

When can 1SFL597001R6811 be shipped?

1SFL597001R6811 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SFL597001R6811 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SFL597001R6811 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SFL597001R6811, subject to availability and destination.

The AF460-30-11-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 250 kW / 400 V AC (AC-3) or 400 hp / 480 V UL and switching power circuits up to 700 A (AC-1) or 650 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Specifications

General

Order code (ABB product ID)1SFL597001R6811
TypeAF460-30-11-68
LifecycleActive (current ABB product)
Country of originIndia

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width186 mm
Product Net Depth / Length216 mm
Product Net Height278 mm
Product Net Weight10.6 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I<sub>th</sub>)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A
Rated Operational Current AC-1 (I<sub>e</sub>)(1000 V) 40 °C 700 A, (1000 V) 55 °C 600 A, (1000 V) 60 °C 600 A, (1000 V) 70 °C 480 A, (690 V) 40 °C 700 A, (690 V) 55 °C 600 A, (690 V) 70 °C 480 A
Rated Operational Current AC-3 (I<sub>e</sub>)(415 V) 55 °C 460 A, (440 V) 55 °C 460 A, (500 V) 55 °C 460 A, (690 V) 55 °C 400 A, (1000 V) 55 °C 200 A, (380 / 400 V) 55 °C 460 A, (220 / 230 / 240 V) 55 °C 460 A
Rated Operational Current DC-1 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 700 A, (110 V) 2 Poles in Series, 40 °C 700 A, (220 V) 3 Poles in Series, 40 °C 700 A, (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-3 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 700 A, (110 V) 2 Poles in Series, 40 °C 700 A, (220 V) 3 Poles in Series, 40 °C 700 A, (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-5 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 700 A, (110 V) 2 Poles in Series, 40 °C 700 A, (220 V) 3 Poles in Series, 40 °C 700 A, (600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Power AC-3 (P<sub>e</sub>)(415 V) 250 kW, (440 V) 250 kW, (500 V) 315 kW, (690 V) 355 kW, (1000 V) 280 kW, (380 / 400 V) 250 kW, (220 / 230 / 240 V) 132 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 1.5 ... 1.8 In A, gG Type Fuses 800 A
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 3100 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 2500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour, (AC-2 / AC-4) 60 cycles per hour, (AC-3) 300 cycles per hour
Mechanical Durability3 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (U<sub>c</sub>)50 Hz 24 ... 60 V, DC Operation 24 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage DC 4.3 W, Pull-in at Max. Rated Control Circuit Voltage DC 1313 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 1313 W
Power Lossat Rated Operating Conditions AC-1 per Pole 43 W, at Rated Operating Conditions AC-3 per Pole 19 W
Operate TimeBetween Coil De-energization and NC Contact Closing 45 ... 55 ms, Between Coil De-energization and NO Contact Opening 48 ... 58 ms, Between Coil Energization and NC Contact Opening 45 ... 115 ms, Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main CircuitBar 47 mm², Rigid Al-Cable 2x240 mm², Rigid Cu-Cable 240 mm², Rigid Cu-Cable 2x240 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 1x0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Connecting CapacityBar 47 mm², Rigid Al-Cable 2x240 mm², Rigid Cu-Cable 2x240 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M10, Control Circuit Pozidriv 2, Control Circuit M3.5
Tightening TorqueCable Lug 35 N·m, Main Circuit 35 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Product NameBlock Contactor

Technical UL/CSA

NEMA Size6
Horsepower Rating NEMA(200 V AC) Three Phase 150 Hp, (230 V AC) Three Phase 200 Hp, (460 V AC) Three Phase 400 Hp, (575 V AC) Three Phase 400 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 650 A, (600 V AC) 650 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 150 Hp, (200 ... 208 V AC) Three Phase 150 hp, (200 V AC) Three Phase 150 hp, (208 V AC) Three Phase 150 hp, (220 ... 240 V AC) Three Phase 200 Hp, (220 ... 240 V AC) Three Phase 200, (440 ... 480 V AC) Three Phase 400 Hp, (440 ... 480 V AC) Three Phase 400 hp, (550 ... 600 V AC) Three Phase 500 Hp, (550 ... 600 V AC) Three Phase 500 hp
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 477 A, (550 ... 600 V AC) Three Phase 472 A

Environmental

Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C, Operation -40 ... 70 °C, Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Shock Direction: A 5 g, Shock Direction: B1 5 g, Shock Direction: B2 5 g, Shock Direction: C1 5 g, Shock Direction: C2 5 g

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Extended Product LifetimeProduct Durability is Enhanced
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 63.1 %

External Classifications and Standards

Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Norway)4115290
E-Number (Sweden)3228342

Downloads & documentation

Official documents from ABB, downloaded directly from the manufacturer.

Data sheets & manuals

Data Sheet, Technical Information (1SBC100214C0202)
Instructions and Manuals (Part 2) (1SAC200017M0002)
Dimension Diagram (53540919-59)
ABB EcoSolutions Profile (1SFC100125C0366)
End Of Life Disassembling Instructions (1SFC100112M0003)

CAD & dimension drawings

CAD Dimensional Drawing (2CDC001079B0201)
Certificates (16)
REACH Declaration (2CMT2021-006202)
RoHS Declaration (2CMT2021-006277)
Environmental Product Declaration - EPD (1SFC100105D0201)
Environmental Product Declaration - EPD (2TFP200031A1001)
ABS Certificate (15-LD1408622-PDA)
CB Certificate (SE-82316)
CCS Certificate (GB14T00030)
CCS Certificate (GZ15T00069)
CQC Certificate (CQC2007010304256683)
CQC Certificate (CQC2011010304514755)
cUL Certificate (20121207-E36588)
Declaration of Conformity - CE (2CMT2019-005796)
Declaration of Conformity - UKCA (2CMT2020-006118)
DNV GL Certificate (TAE00001W1)
LOVAG Certificate (SE-0115087)
LR Certificate (16-20064)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More ABB parts

AF460N6-30-11-69 ContactorAvailable on requestAF460N6-30-11-69 Contactor
MPN: 1SFL597001N6911 · ABB
Price on request
Request a quote
AF460N6-30-11-70 ContactorAvailable on requestAF460N6-30-11-70 Contactor
MPN: 1SFL597001N7011 · ABB
Price on request
Request a quote
AF460N6-30-11-71 ContactorAvailable on requestAF460N6-30-11-71 Contactor
MPN: 1SFL597001N7111 · ABB
Price on request
Request a quote
AF460-30-00-68 ContactorAvailable on requestAF460-30-00-68 Contactor
MPN: 1SFL597001R6800 · ABB
Price on request
Request a quote
AF460-30-22-68 24-60V DC ContactorAvailable on requestAF460-30-22-68 24-60V DC Contactor
MPN: 1SFL597001R6822 · ABB
Price on request
Request a quote
AF460-30-00-69 ContactorAvailable on requestAF460-30-00-69 Contactor
MPN: 1SFL597001R6900 · ABB
Price on request
Request a quote
AF460-30-11 48-130V 50/60Hz / 48-130V DC ContactorAvailable on requestAF460-30-11 48-130V 50/60Hz / 48-130V DC Contactor
MPN: 1SFL597001R6911 · ABB
Price on request
Request a quote
AF460-30-22-69 48-130V 50/60Hz / 48-130V DC ContactorAvailable on requestAF460-30-22-69 48-130V 50/60Hz / 48-130V DC Contactor
MPN: 1SFL597001R6922 · ABB
Price on request
Request a quote