Available on request

ABB 1SFL577081R6812 – AFS400-30-12-68 Block Contactor

MPN: 1SFL577081R6812 · Brand: ABB
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryABB AFS Contactors
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
Weight10.6 kg
UPC / EAN7320500540930

Shipping & availability

When can 1SFL577081R6812 be shipped?

1SFL577081R6812 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 1SFL577081R6812 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 1SFL577081R6812 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SFL577081R6812, subject to availability and destination.

The AFS400-30-12-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted 1 left (1 N.O + 1 N.C.) and fixed 1 right (1 N.C.) side mounted auxiliary contact blocks with Main Circuit Bars connections, controlling motors up to 200 kW / 400 V AC (AC-3) or 350 hp / 480 V UL and switching power circuits up to 600 A (AC-1) or 550 A UL general use. AFS contactors can be easily integrated in machine manufacturer’s systems complying with main standards EN ISO 13849 and EN 62061 - guaranteeing the safe use of your machinery and equipment. An easily identifiable yellow low energy auxiliary contact block ensures the status feedback circuits required in machine safety applications. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Specifications

General

Order code (ABB product ID)1SFL577081R6812
TypeAFS400-30-12-68
LifecycleActive (current ABB product)

Ordering

Minimum Order Quantity1 piece
Customs Tariff Number85364900

Dimensions

Product Net Width186 mm
Product Net Depth / Length216 mm
Product Net Height278 mm
Product Net Weight10.6 kg

Technical

Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC2
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I<sub>th</sub>)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A
Rated Operational Current AC-1 (I<sub>e</sub>)(1000 V) 40 °C 600 A, (1000 V) 55 °C 500 A, (1000 V) 70 °C 400 A, (690 V) 40 °C 600 A, (690 V) 55 °C 500 A, (690 V) 70 °C 400 A
Rated Operational Current AC-3 (I<sub>e</sub>)(415 V) 55 °C 400 A, (440 V) 55 °C 400 A, (500 V) 55 °C 400 A, (690 V) 55 °C 350 A, (1000 V) 55 °C 155 A, (380 / 400 V) 55 °C 400 A, (220 / 230 / 240 V) 55 °C 400 A
Rated Operational Current DC-1 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 600 A, (110 V) 2 Poles in Series, 40 °C 600 A, (220 V) 3 Poles in Series, 40 °C 600 A, (600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-3 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 600 A, (110 V) 2 Poles in Series, 40 °C 600 A, (220 V) 3 Poles in Series, 40 °C 600 A, (600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Current DC-5 (I<sub>e</sub>)(110 V) 1-Pole, 40 °C 600 A, (110 V) 2 Poles in Series, 40 °C 600 A, (220 V) 3 Poles in Series, 40 °C 600 A, (600 V) 3 Poles in Series, 40 °C 600 A
Rated Operational Power AC-3 (P<sub>e</sub>)(415 V) 220 kW, (440 V) 220 kW, (500 V) 250 kW, (690 V) 315 kW, (1000 V) 220 kW, (380 / 400 V) 200 kW, (220 / 230 / 240 V) 110 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Short-Circuit Protective DevicesgG Type Fuses 630 A
Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 3100 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 2500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A
Rated Insulation Voltage (U<sub>i</sub>)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U<sub>imp</sub>)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour, (AC-2 / AC-4) 60 cycles per hour, (AC-3) 300 cycles per hour
Mechanical Durability3 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (U<sub>c</sub>)50 Hz 24 ... 60 V, DC Operation 24 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage DC 4.3 W, Pull-in at Max. Rated Control Circuit Voltage DC 1313 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 1313 W
Power Lossat Rated Operating Conditions AC-1 per Pole 32 W, at Rated Operating Conditions AC-3 per Pole 14 W
Operate TimeBetween Coil De-energization and NC Contact Closing 45 ... 55 ms, Between Coil De-energization and NO Contact Opening 48 ... 58 ms, Between Coil Energization and NC Contact Opening 45 ... 115 ms, Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main CircuitBar 47 mm², Rigid Al-Cable 240 mm², Rigid Al-Cable 2x240 mm², Rigid Cu-Cable 240 mm², Rigid Cu-Cable 2x240 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 1x0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm²
Connecting CapacityBar 47 mm², Rigid Al-Cable 2x240 mm², Rigid Cu-Cable 2x240 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M10, Control Circuit 5.5, Control Circuit M3.5, Control Circuit Pozidriv 2
Tightening TorqueCable Lug 35 N·m, Main Circuit 35 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Product NameBlock Contactor

Technical UL/CSA

Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 550 A, (600 V AC) 550 A
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 125 Hp, (200 ... 208 V AC) Three Phase 125 hp, (200 V AC) Three Phase 125 hp, (208 V AC) Three Phase 125 hp, (220 ... 240 V AC) Three Phase 150 Hp, (220 ... 240 V AC) Three Phase 150, (440 ... 480 V AC) Three Phase 350 Hp, (440 ... 480 V AC) Three Phase 350 hp, (550 ... 600 V AC) Three Phase 400 Hp, (550 ... 600 V AC) Three Phase 400 hp
Full Load Amps Motor Use(200 ... 208 V AC) Three Phase 358.8 A, (220 ... 240 V AC) Three Phase 360 A, (440 ... 480 V AC) Three Phase 414 A, (550 ... 600 V AC) Three Phase 382 A

Environmental

Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C, Operation -40 ... 70 °C, Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Shock Direction: A 5 g, Shock Direction: B1 5 g, Shock Direction: B2 5 g, Shock Direction: C1 5 g, Shock Direction: C2 5 g

Material Compliance

RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Extended Product LifetimeProduct Durability is Enhanced
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 63.1 %

External Classifications and Standards

Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3709036

Downloads & documentation

Official documents from ABB, downloaded directly from the manufacturer.

Data sheets & manuals

Data Sheet, Technical Information (1SBC100214C0202)
Instructions and Manuals (Part 2) (1SAC200017M0002)
ABB EcoSolutions Profile (1SFC100125C0366)
End Of Life Disassembling Instructions (1SFC100112M0003)

CAD & dimension drawings

CAD Dimensional Drawing (2CDC001079B0201)
Certificates (12)
REACH Declaration (2CMT2021-006202)
RoHS Declaration (2CMT2021-006277)
Environmental Product Declaration - EPD (1SFC100105D0201)
CB Certificate (SE-82316)
CCS Certificate (GB14T00030)
CCS Certificate (GZ15T00069)
CQC Certificate (CQC2007010304256683)
cUL Certificate (20121207-E36588)
Declaration of Conformity - CE (2CMT2018-005695)
Declaration of Conformity - UKCA (2CMT2020-006125)
EAC Certificate (1SFC101360D1101)
SUVA Certificate (2CMT2019-005859)
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More ABB parts

AF400B-30-22-68 24-60 V DC ContactorAvailable on requestAF400B-30-22-68 24-60 V DC Contactor
MPN: 1SFL577063R6822 · ABB
Price on request
Request a quote
AF400B-30-22-69 48-130V 50/60Hz / 48-130V DC ContactorAvailable on requestAF400B-30-22-69 48-130V 50/60Hz / 48-130V DC Contactor
MPN: 1SFL577063R6922 · ABB
Price on request
Request a quote
AF400B-30-22-70 100-250V 50/60Hz / 100-250V DC ContactorAvailable on requestAF400B-30-22-70 100-250V 50/60Hz / 100-250V DC Contactor
MPN: 1SFL577063R7022 · ABB
Price on request
Request a quote
AF400-30-22-71 250-500V 50/60Hz / 250-500V DC ContactorAvailable on requestAF400-30-22-71 250-500V 50/60Hz / 250-500V DC Contactor
MPN: 1SFL577063R7122 · ABB
Price on request
Request a quote
AFS400-30-12-69 Block ContactorAvailable on requestAFS400-30-12-69 Block Contactor
MPN: 1SFL577081R6912 · ABB
Price on request
Request a quote
AFS400-30-12-70 Block ContactorAvailable on requestAFS400-30-12-70 Block Contactor
MPN: 1SFL577081R7012 · ABB
Price on request
Request a quote
AFS400-30-12-71 Block ContactorAvailable on requestAFS400-30-12-71 Block Contactor
MPN: 1SFL577081R7112 · ABB
Price on request
Request a quote
AF305-30-00-11 ContactorAvailable on requestAF305-30-00-11 Contactor
MPN: 1SFL587002R1100 · ABB
Price on request
Request a quote