ABB 1SFL487002R1211 – AF190-30-11-12 Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AF Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 2.4 kg |
| Country of origin | India |
| UPC / EAN | 7320500480427 |
Shipping & availability
When can 1SFL487002R1211 be shipped?
1SFL487002R1211 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SFL487002R1211 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SFL487002R1211 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SFL487002R1211, subject to availability and destination.
The AF190-30-11-12 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, controlling motors up to 90 kW / 400 V AC (AC-3) or 125 hp / 480 V UL and switching power circuits up to 275 A (AC-1) or 250 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (48-130 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories. Includes Mounting kit, containing all neccessary screws, washers and sockets for connecting the terminals, and screws for mounting the device.
Specifications
General
| Order code (ABB product ID) | 1SFL487002R1211 |
| Type | AF190-30-11-12 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 105 mm |
| Product Net Depth / Length | 152 mm |
| Product Net Height | 196 mm |
| Product Net Weight | 2.4 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 275 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (1000 V) 40 °C 250 A, (1000 V) 60 °C 225 A, (1000 V) 70 °C 185 A, (690 V) 40 °C 275 A, (690 V) 60 °C 250 A, (690 V) 70 °C 200 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 60 °C 190 A, (440 V) 60 °C 190 A, (500 V) 60 °C 156 A, (690 V) 60 °C 85 A, (1000 V) 60 °C 85 A, (380 / 400 V) 60 °C 190 A, (220 / 230 / 240 V) 60 °C 190 A |
| Rated Operational Current AC-3e (I<sub>e</sub>) | (415 V) 60 °C 190 A, (440 V) 60 °C 190 A, (500 V) 60 °C 135 A, (690 V) 60 °C 135 A, (1000 V) 60 °C 85 A, (380 / 400 V) 60 °C 190 A, (220 / 230 / 240 V) 60 °C 190 A |
| Rated Operational Current DC-1 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-3 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-5 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 90 kW, (440 V) 110 kW, (500 V) 110 kW, (690 V) 132 kW, (1000 V) 110 kW, (380 / 400 V) 90 kW, (220 / 230 / 240 V) 55 kW |
| Rated Operational Power AC-3e (P<sub>e</sub>) | (415 V) 90 kW, (440 V) 110 kW, (500 V) 110 kW, (690 V) 132 kW, (1000 V) 110 kW, (380 / 400 V) 90 kW, (220 / 230 / 240 V) 55 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 355 A |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 275 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 621 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 878 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3300 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2200 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 1000 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 48 ... 130 V, 60 Hz 48 ... 130 V, DC Operation 48 ... 130 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 15.2 V·A, Holding at Max. Rated Control Circuit Voltage 50 Hz 2.6 W, Holding at Max. Rated Control Circuit Voltage 60 Hz 15.2 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 2.6 W, Holding at Max. Rated Control Circuit Voltage DC 2.6 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 368 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 368 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 499 V·A, Pull-in at Max. Rated Control Circuit Voltage DC 499 W |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 9 W, at Rated Operating Conditions AC-3 per Pole 4 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms, Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 50 ... 95 mm², Rigid Al-Cable 1 x 95 ... 185 mm², Rigid Cu-Cable 1 x 6 ... 150 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 1x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 50 ... 95 mm², Rigid Al-Cable 1 x 95 ... 185 mm², Rigid Cu-Cable 1 x 6 ... 150 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque | Cable Lug 18 N·m, Main Circuit 14 ... 31 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
Technical UL/CSA
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 250 A, (600 V AC) 275 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 50 hp, (208 V AC) Three Phase 50 hp, (220 ... 240 V AC) Three Phase 60, (440 ... 480 V AC) Three Phase 125 hp, (550 ... 600 V AC) Three Phase 150 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 156 A, (550 ... 600 V AC) Three Phase 144 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
ABB EcoSolutions
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility, UL 2799 Zero Waste To Landfill Validation available |
| Extended Product Lifetime | Product Durability is Enhanced |
| Improved Energy Efficiency for Customers | Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line, Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3706391 |
| E-Number (Norway) | 4117639 |
| E-Number (Sweden) | 3210133 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (16)
More ABB parts
Available on requestAF190-30-00-11 Contactor
Available on requestAF190-30-11-11 Contactor
Available on requestAF190-30-22-11 Contactor
Available on requestAF190-30-00-12 Contactor
Available on requestAF190-30-22-12 Contactor
Available on requestAF190-30-00-13 Contactor
Available on requestAF190-30-01-13 Contactor
Available on requestAF190-30-11-13 Contactor