ABB 1SFL471001R5111 – A145-30-11 400-415V 50Hz / 480V 60Hz Contactor
Discontinued by ABB — we can still source the original 1SFL471001R5111 (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB A Contactors |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 2.9 kg |
| UPC / EAN | 7320500203453 |
Shipping & availability
Can I still buy the 1SFL471001R5111 now that it is discontinued?
Yes. ABB has discontinued the 1SFL471001R5111, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can 1SFL471001R5111 be shipped?
1SFL471001R5111 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SFL471001R5111 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SFL471001R5111 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SFL471001R5111, subject to availability and destination.
A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V.Operated with control voltage, versions from 24….690 AC, 50 and 60 Hz
Lifecycle: ABB lists this product as inactive (discontinued). PartnerPLC sources discontinued ABB parts — request a quote for availability, or ask us about the current ABB successor.
Specifications
General
| Order code (ABB product ID) | 1SFL471001R5111 |
| Type | A145-30-11-51 |
| Lifecycle | Discontinued (inactive at ABB) |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Replacement Product ID (NEW) | 1SFL447002R1411 |
Dimensions
| Product Net Width | 111.5 mm |
| Product Net Depth / Length | 160 mm |
| Product Net Height | 196 mm |
| Product Net Weight | 2.9 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (1000 V) 40 °C 180 A, (1000 V) 55 °C 180 A, (1000 V) 70 °C 180 A, (690 V) 40 °C 250 A, (690 V) 55 °C 230 A, (690 V) 70 °C 180 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 145 A, (440 V) 55 °C 145 A, (500 V) 55 °C 145 A, (690 V) 55 °C 120 A, (1000 V) 55 °C 80 A, (380 / 400 V) 55 °C 145 A, (220 / 230 / 240 V) 55 °C 145 |
| Rated Operational Current DC-1 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-3 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Current DC-5 (I<sub>e</sub>) | (110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 75 kW, (440 V) 75 kW, (500 V) 90 kW, (690 V) 110 kW, (380 / 400 V) 75 kW, (220 / 230 / 240 V) 45 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 315 A |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V, acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour, (AC-2 / AC-4) 150 cycles per hour, (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 400 ... 415 V, 60 Hz 480 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A, Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A, Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A |
| Power Loss | at Rated Operating Conditions per Pole 5 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 5 ... 10 ms, Between Coil De-energization and NO Contact Opening 9 ... 13 ms, Between Coil Energization and NC Contact Opening 8 ... 22 ms, Between Coil Energization and NO Contact Closing 13 ... 27 ms |
| Connecting Capacity Main Circuit | Bar 24 mm², Rigid Al-Cable 1 x 25 ... 150 mm², Rigid Cu-Cable 1 x 6 ... 185 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm², Flexible 2x0.75 ... 2.5 mm², Solid 2 x 1 ... 4 mm², Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Bar 24 mm², Rigid Al-Cable 1 x 25 ... 150 mm², Rigid Cu-Cable 1 x 6 ... 185 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Connecting Terminals (delivered in open position) Main Poles | Flat type c/w screws and bolts |
| Tightening Torque | Main Circuit 18 N·m |
| Terminal Type | Main Circuit: Bars |
| Product Name | Block Contactor |
Technical UL/CSA
| NEMA Size | 4 |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 230 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 40 hp, (208 V AC) Three Phase 40 hp, (220 ... 240 V AC) Three Phase 50, (440 ... 480 V AC) Three Phase 100 hp, (550 ... 600 V AC) Three Phase 125 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 124 A, (550 ... 600 V AC) Three Phase 125 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C, Close to Contactor for Storage -40 ... 70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g, Shock Direction: B1 5 g, Shock Direction: B2 5 g, Shock Direction: C1 5 g, Shock Direction: C2 5 g |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100192C0206) | |
| Instructions and Manuals (1SFC380003-89) |
Certificates (10)
More ABB parts
Available on requestA145-30-00 400V 50Hz Contactor
Available on requestA145-30-11 400V 50Hz / 440V 60Hz Contactor
Available on requestA145-30-22 400V 50Hz / 440V 60Hz Contactor
Available on requestA145-30-00 400-415V 50Hz Contactor
Available on requestA145-30-22 400-415V 50Hz / 480V 60Hz Contactor
Available on requestA145-30-11 440V 50Hz / 500V 60Hz Contactor
Available on requestA145-30-22 440V 50Hz / 500V 60Hz Contactor
Available on requestA145-30-11 220V 50Hz / 220-240V 60Hz Contactor